摘要
This paper describes further investigations and results in the reduction of residual signal in Harshaw TLD-100H, 600H and 700H (LiF:Mg,Cu,P). TLD-100H is an advanced, relatively new dosimetric material with near tissue-equivalence, flat energy response, and the ability to measure beta, photon and, more importantly, neutrons all from the same base material. The simple glow curve structure provides insignificant fade over extended dosimetric periods of up to 1 y. A criticism of the material has been the residual as compared with TLD-100 (LiF:Mg,Ti). We will show how high-temperature peaks cause the residual signal. We will also show how the various parameters and conditions of the residual measurement technique as well as the configuration of the sample affect the residual measurements. A brief description of the experimental paths taken during our investigation will be presented. We will show how we have reduced the high-temperature peaks of LiF:Mg,Cu,P in our manufacturing process while not affecting other dosimetric properties of this material. The improvements and material properties that need to be shown have been incorporated into our production processes. LiF:Mg,Cu,P stands as a premier choice for personal dosimetry and has been integrated into personal, environmental and extremity configurations of the Harshaw TLD family-line of products.
引用
收藏
页码:217 / 219
页数:3
相关论文
共 50 条
  • [42] Application of LiF:Mg,Cu,P (MCP-N) thermoluminescent detectors (TLD) for experimental verification of radial dose distribution models
    Gieszczyk, Wojciech
    Olko, Pawel
    Bilski, Pawel
    Grzanka, Leszek
    Obryk, Barbara
    Horwacik, Tomasz
    NUKLEONIKA, 2012, 57 (04) : 507 - 512
  • [43] APPLICATION OF THERMOLUMINESCENCE DOSIMETRY IN THE EXPLORATION FOR OIL AND GAS-USING CHINESE GR-200 LIF (MG,CU,P) TLD
    WANG, Z
    QIN, D
    ZHUANG, G
    ZHA, Z
    WANG, S
    SHEN, W
    CAI, G
    RADIATION PROTECTION DOSIMETRY, 1993, 47 (1-4) : 323 - 326
  • [44] A performance comparison of Thermo Fisher EPD-MK2 and TLD (LiF:Mg,Cu,P) as part of accreditation proficiency testing
    Benevides, L. A.
    Piper, R. K.
    Romanyukha, A.
    RADIATION MEASUREMENTS, 2014, 71 : 183 - 186
  • [45] Performance comparison of OSLD (Al2O3:C) and TLD (LiF:Mg,Cu,P) in accreditation proficiency testing
    Romanyukha, A.
    Grypp, M. D.
    Fairchild, G. R.
    Williams, A. S.
    RADIATION MEASUREMENTS, 2016, 93 : 7 - 12
  • [46] X-RAY-DIFFRACTION AND ESR STUDIES ON LIF-MG,CU,P PHOSPHOR
    SUN, F
    JIAO, L
    WU, J
    YANG, Z
    YUAN, S
    DAI, G
    RADIATION PROTECTION DOSIMETRY, 1994, 51 (03) : 183 - 189
  • [47] Influence of readout parameters on TL response, re-usability and residual signal in LiF:Mg,Cu,P
    Tang, K
    Zhao, J
    Shen, W
    Zhu, H
    Wang, Y
    Liu, B
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 353 - 356
  • [48] Study of a new Lif:Mg,Cu,P formulation with enhanced thermal stability and a lower residual TL signal
    Tang, K.
    Cui, H.
    Zhu, H.
    Fan, Q.
    RADIATION MEASUREMENTS, 2007, 42 (01) : 24 - 28
  • [49] Influence of readout parameters on TL response, re-usability and residual signal in LiF:Mg,Cu,P
    Tang, K
    Zhao, J
    Shen, W
    Zhu, H
    Wang, Y
    Liu, B
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 353 - 356
  • [50] Further study on the influence of thermal treatments on the glow curve structure in LiF:Mg,Cu,P (GR-200A)
    Tang, K.
    Fan, H.
    Cui, H.
    Zhu, H.
    Liu, Z.
    RADIATION MEASUREMENTS, 2014, 63 : 1 - 5