A bioabsorbable plug in bone-tendon-bone reconstruction of the anterior cruciate ligament:: Introduction of a novel fixation technique

被引:0
|
作者
Kousa, P
Järvinen, TLN
Kannus, P
Ahvenjärvi, P
Kaikkonen, A
Järvinen, M
机构
[1] Univ Tampere, Sch Med, Dept Surg, Tampere 33101, Finland
[2] Univ Tampere, Inst Med Technol, Tampere 33101, Finland
[3] Tampere Univ Hosp, Dept Surg, Tampere, Finland
[4] Urho Kaleva Kekkonen Inst Hlth Promot Res, Accident & Trauma Res Ctr, Tampere, Finland
[5] Tampere Res Ctr Sports Med, Tampere, Finland
[6] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
来源
ARTHROSCOPY | 2001年 / 17卷 / 02期
关键词
anterior cruciate ligament; fixation; interference screw; biomechanical testing; cyclic loading; bioabsorbable;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Our aim was to compare the fixation strength of a novel plugging technique with that of the conventional interference technique in bone-patellar tendon-bone reconstruction of the anterior cruciate ligament. Type of Study: Randomized experimental study. Methods: Twenty matched pairs of porcine knees were randomly assigned to 2 groups. The bone block of the graft was secured in the femoral drill hole with either the new bioabsorbable poly-L-lactide/D-lactide (PLA 96.4) copolymer plug (plugging technique) (n = 20) or a conventional interference screw (interference technique) (n = 20). Ten pairs were subjected to a single cycle loading test at a rate of 50 mm/min while the remaining 10 pairs underwent a cyclic loading test to further assess the quality of the fixation. The cyclic loading test consisted of 1,500 loading cycles between 50 and 200 N at half-hertz frequency, after which the specimens were loaded to failure at a rate of 50 mm/min. Results: In the single cycle loading test, the average ultimate failure load was 1,061 +/- 342 N in the plugging technique group and 971 +/- 260 N in the interference technique group (P = .57). Significant group differences were found neither in the yield loads nor observed between the 2 fixation techniques. There were neither significant group differences with regard to the ultimate failure load (plugging technique 994 +/- 376 N versus interference technique 1,001 +/- 343 N, P = .97) nor yield load of the fixations in the subsequent single cycle loading. Conclusions: the results of this study indicate that, in anterior cruciate ligament reconstruction, the new plugging technique is a reasonable alternative for fixation of the femoral site of a bone-patellar tendon-bone graft.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [31] Anterior cruciate ligament reconstruction autograft choice: Bone-tendon-bone versus hamstring - Does it really matter? A systematic review
    Spindler, KR
    Kuhn, JE
    Freedman, KB
    Matthews, CE
    Dittus, RS
    Harrell, FE
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (08): : 1986 - 1995
  • [32] Intraoperative fracture of patellar bone plug during anterior cruciate ligament reconstruction with bone–patellar tendon–bone: clinical case
    Andrea Emilio Salvi
    Giovanni Pietro Metelli
    Giovanni Musella
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 58 - 60
  • [33] Enhanced Bone-Tendon-Bone Approach for Open Anterior Cruciate Ligament Replacement With Conservation of the Joint Capsule
    Walter, Sebastian Gottfried
    Thomas, Tom Sascha
    Tafuro, Luca
    Thomas, Wolfram
    ARTHROSCOPY TECHNIQUES, 2015, 4 (05): : E609 - E613
  • [34] Press-fit fixation in reconstruction of anterior cruciate ligament, using bone–patellar tendon–bone graft
    Moustafa Al-Husseiny
    Khaled Batterjee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 104 - 109
  • [35] Tibial Fixation in Anterior Cruciate Ligament Reconstruction With Bone-Patellar Tendon-Bone and Semitendinosus-Gracilis Autografts A Comparison Between Bioabsorbable Screws and Bioabsorbable Cross-Pin Fixation
    Volpi, Piero
    Marinoni, Luca
    Bait, Corrado
    Galli, Marco
    de Girolamo, Laura
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (04): : 808 - 812
  • [36] Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction: A preliminary report
    Marti C.
    Imhoff A.B.
    Bahrs C.
    Romero J.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1997, 5 (4) : 217 - 221
  • [37] Refilling of removal defects:: Impact on extensor mechanism complaints after use of a bone-tendon-bone graft for anterior cruciate ligament reconstruction
    Boszotta, H
    Prünner, K
    ARTHROSCOPY, 2000, 16 (02): : 160 - 164
  • [38] Bone density may affect primary stability of anterior cruciate ligament reconstruction when organic core bone plug fixation technique used
    Dehestani, Pouya
    Farahmand, Farzam
    Borjali, Amirhossein
    Bashti, Kaveh
    Chizari, Mahmoud
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [39] Bone density may affect primary stability of anterior cruciate ligament reconstruction when organic core bone plug fixation technique used
    Pouya Dehestani
    Farzam Farahmand
    Amirhossein Borjali
    Kaveh Bashti
    Mahmoud Chizari
    Journal of Experimental Orthopaedics, 9
  • [40] Femoral bone plug recession in endoscopic anterior cruciate ligament reconstruction
    Taylor, DE
    Dervin, GF
    Keene, GCR
    ARTHROSCOPY, 1996, 12 (04): : 513 - 515