A bioabsorbable plug in bone-tendon-bone reconstruction of the anterior cruciate ligament:: Introduction of a novel fixation technique

被引:0
|
作者
Kousa, P
Järvinen, TLN
Kannus, P
Ahvenjärvi, P
Kaikkonen, A
Järvinen, M
机构
[1] Univ Tampere, Sch Med, Dept Surg, Tampere 33101, Finland
[2] Univ Tampere, Inst Med Technol, Tampere 33101, Finland
[3] Tampere Univ Hosp, Dept Surg, Tampere, Finland
[4] Urho Kaleva Kekkonen Inst Hlth Promot Res, Accident & Trauma Res Ctr, Tampere, Finland
[5] Tampere Res Ctr Sports Med, Tampere, Finland
[6] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
来源
ARTHROSCOPY | 2001年 / 17卷 / 02期
关键词
anterior cruciate ligament; fixation; interference screw; biomechanical testing; cyclic loading; bioabsorbable;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Our aim was to compare the fixation strength of a novel plugging technique with that of the conventional interference technique in bone-patellar tendon-bone reconstruction of the anterior cruciate ligament. Type of Study: Randomized experimental study. Methods: Twenty matched pairs of porcine knees were randomly assigned to 2 groups. The bone block of the graft was secured in the femoral drill hole with either the new bioabsorbable poly-L-lactide/D-lactide (PLA 96.4) copolymer plug (plugging technique) (n = 20) or a conventional interference screw (interference technique) (n = 20). Ten pairs were subjected to a single cycle loading test at a rate of 50 mm/min while the remaining 10 pairs underwent a cyclic loading test to further assess the quality of the fixation. The cyclic loading test consisted of 1,500 loading cycles between 50 and 200 N at half-hertz frequency, after which the specimens were loaded to failure at a rate of 50 mm/min. Results: In the single cycle loading test, the average ultimate failure load was 1,061 +/- 342 N in the plugging technique group and 971 +/- 260 N in the interference technique group (P = .57). Significant group differences were found neither in the yield loads nor observed between the 2 fixation techniques. There were neither significant group differences with regard to the ultimate failure load (plugging technique 994 +/- 376 N versus interference technique 1,001 +/- 343 N, P = .97) nor yield load of the fixations in the subsequent single cycle loading. Conclusions: the results of this study indicate that, in anterior cruciate ligament reconstruction, the new plugging technique is a reasonable alternative for fixation of the femoral site of a bone-patellar tendon-bone graft.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [21] Fixation of the tibial bone block in patellar tendon anterior cruciate ligament reconstruction
    Davies, GT
    Pun, WK
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (05): : 691 - 691
  • [22] Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction
    Brand, J
    Hamilton, D
    Selby, J
    Pienkowski, D
    Caborn, DNM
    Johnson, DL
    ARTHROSCOPY, 2000, 16 (08): : 805 - 812
  • [23] Tubularization of Bone-Tendon-Bone Grafts: Effects on Mechanical Strength and Postoperative Knee Stability in Anterior Cruciate Ligament Reconstruction
    Obradovic, Mirko
    Ninkovic, Srdan
    Gvozdenovic, Nemanja
    Tosic, Milan
    Milinkov, Milan
    Dulic, Oliver
    MEDICINA-LITHUANIA, 2023, 59 (10):
  • [24] The effect of cyclic loading on rotated bone-tendon-bone anterior cruciate ligament graft constructs
    Berkson, Eric
    Lee, Gregory H.
    Kumar, Ashwin
    Verma, Nikhil
    Bach, Bernard R., Jr.
    Hallab, Nadim
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (09): : 1442 - 1449
  • [25] Real-time elastography of patellar tendon in patients with auto-graft bone-tendon-bone anterior cruciate ligament reconstruction
    Akkaya, Semih
    Akkaya, Nuray
    Agladioglu, Kadir
    Gungor, Harun R.
    Ok, Nusret
    Ozcakar, Levent
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (06) : 837 - 842
  • [26] Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation
    Janosch Häberli
    Maximilian Heilgemeir
    Sebastian Valet
    Ameet Aiyangar
    Tom Overes
    Philipp Henle
    Stefan Eggli
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1963 - 1970
  • [27] Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation
    Haberli, Janosch
    Heilgemeir, Maximilian
    Valet, Sebastian
    Aiyangar, Ameet
    Overes, Tom
    Henle, Philipp
    Eggli, Stefan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (08) : 1963 - 1970
  • [28] Is screw divergence in femoral bone-tendon-bone graft fixation avoidable in anterior cruciate ligament reconstruction using a single-incision technique?: A radiographically controlled cadaver study
    Hackl, W
    Benedetto, KP
    Hoser, C
    Künzel, KH
    Fink, C
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (06): : 640 - 647
  • [29] Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction
    Caborn, DNM
    Selby, JB
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01): : 102 - 105
  • [30] A novel silk-TCP-PEEK construct for anterior cruciate ligament reconstruction: an off-the shelf alternative to a bone-tendon-bone autograft
    Li, Xiang
    He, Jiankang
    Bian, Weiguo
    Li, Zheng
    Li, Dichen
    Snedeker, Jess G.
    BIOFABRICATION, 2014, 6 (01)