A bioabsorbable plug in bone-tendon-bone reconstruction of the anterior cruciate ligament:: Introduction of a novel fixation technique

被引:0
|
作者
Kousa, P
Järvinen, TLN
Kannus, P
Ahvenjärvi, P
Kaikkonen, A
Järvinen, M
机构
[1] Univ Tampere, Sch Med, Dept Surg, Tampere 33101, Finland
[2] Univ Tampere, Inst Med Technol, Tampere 33101, Finland
[3] Tampere Univ Hosp, Dept Surg, Tampere, Finland
[4] Urho Kaleva Kekkonen Inst Hlth Promot Res, Accident & Trauma Res Ctr, Tampere, Finland
[5] Tampere Res Ctr Sports Med, Tampere, Finland
[6] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
来源
ARTHROSCOPY | 2001年 / 17卷 / 02期
关键词
anterior cruciate ligament; fixation; interference screw; biomechanical testing; cyclic loading; bioabsorbable;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Our aim was to compare the fixation strength of a novel plugging technique with that of the conventional interference technique in bone-patellar tendon-bone reconstruction of the anterior cruciate ligament. Type of Study: Randomized experimental study. Methods: Twenty matched pairs of porcine knees were randomly assigned to 2 groups. The bone block of the graft was secured in the femoral drill hole with either the new bioabsorbable poly-L-lactide/D-lactide (PLA 96.4) copolymer plug (plugging technique) (n = 20) or a conventional interference screw (interference technique) (n = 20). Ten pairs were subjected to a single cycle loading test at a rate of 50 mm/min while the remaining 10 pairs underwent a cyclic loading test to further assess the quality of the fixation. The cyclic loading test consisted of 1,500 loading cycles between 50 and 200 N at half-hertz frequency, after which the specimens were loaded to failure at a rate of 50 mm/min. Results: In the single cycle loading test, the average ultimate failure load was 1,061 +/- 342 N in the plugging technique group and 971 +/- 260 N in the interference technique group (P = .57). Significant group differences were found neither in the yield loads nor observed between the 2 fixation techniques. There were neither significant group differences with regard to the ultimate failure load (plugging technique 994 +/- 376 N versus interference technique 1,001 +/- 343 N, P = .97) nor yield load of the fixations in the subsequent single cycle loading. Conclusions: the results of this study indicate that, in anterior cruciate ligament reconstruction, the new plugging technique is a reasonable alternative for fixation of the femoral site of a bone-patellar tendon-bone graft.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [1] Supplementary Tibial Fixation in Anterior Cruciate Ligament Reconstruction With Bone-Tendon-Bone Graft
    Leyes, Manuel
    Gonzalez-Martin, David
    Flores-Lozano, Cesar
    Gonzalez-Salvador, Maria
    Martin-Buenadicha, Eulogio
    Garcia-Crespo, Rodrigo
    ARTHROSCOPY TECHNIQUES, 2022, 11 (09): : E1551 - E1556
  • [2] Medial Meniscus Transplantation and Bone-Tendon-Bone Anterior Cruciate Ligament Reconstruction
    Yanke, Adam B.
    Huddleston, Hailey P.
    Chahla, Jorge
    Cole, Brian J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (03) : 104 - 110
  • [3] Anterior cruciate ligament reconstruction: Soft tissue vs bone-tendon-bone
    Predescu, Vlad
    Georgeanu, Vlad
    Prescura, Catalin
    Stoian, Valentin
    Cristea, Stefan
    2010 ADVANCED TECHNOLOGIES FOR ENHANCING QUALITY OF LIFE (AT-EQUAL), 2010, : 53 - 57
  • [4] Functional results after anterior cruciate ligament reconstruction using the patellar ligament bone-tendon-bone technique
    Sommer, M
    Amon, D
    Schneider, M
    Woelling, A
    Kohl, KP
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2001, 121 (06) : 317 - 320
  • [5] Protection of the bone-tendon-bone graft during anterior cruciate ligament reconstruction
    Miroslav Milankov
    Milan Stankovic
    Natasa Miljkovic
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 288 - 290
  • [6] Protection of the bone-tendon-bone graft during anterior cruciate ligament reconstruction
    Milankov, M
    Stankovic, M
    Miljkovic, N
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (04) : 288 - 290
  • [7] Functional results after anterior cruciate ligament reconstruction using the patellar ligament bone-tendon-bone technique
    M. Sommer
    D. Amon
    M. Schneider
    A. Woelling
    K. P. Kohl
    Archives of Orthopaedic and Trauma Surgery, 2001, 121 : 317 - 320
  • [8] MORPHOLOGIC CHANGES IN THE HUMAN PATELLAR TENDON AFTER BONE-TENDON-BONE ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    MEISTERLING, RC
    WADSWORTH, T
    ARDILL, R
    GRIFFITHS, H
    LANELARSEN, CL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (289) : 208 - 212
  • [9] THE BIOMECHANICAL EFFECTS OF GEOMETRIC CONFIGURATION OF BONE-TENDON-BONE AUTOGRAFTS IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    SHAPIRO, JD
    COHN, BT
    JACKSON, DW
    POSTAK, PD
    PARKER, RD
    GREENWALD, AS
    ARTHROSCOPY, 1992, 8 (04): : 453 - 458
  • [10] Bone tunnel enlargement after the reconstruction of anterior cruciate ligament using bone-tendon-bone graft
    Ninkovic, Srdjan
    Harhaji, Vladimir
    Rasovic, Predrag
    Gvozdenovic, Nemanja
    Obradovic, Mirko
    VOJNOSANITETSKI PREGLED, 2018, 75 (07) : 682 - 690