Application of a hybrid grounding scheme to a paper mill 13.8 kV generator

被引:1
|
作者
Moody, D [1 ]
Beachum, V [1 ]
Natali, T [1 ]
Vilcheck, W [1 ]
Shipp, DD [1 ]
机构
[1] MeadWestvaco, Luke, MD 21540 USA
关键词
hybrid generator grounding; stator ground fault; core damage; ground differential;
D O I
10.1109/PAPCON.2003.1216906
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Many paper mills and other industries use turbine generators to supply critical process steam and electrical generation needs within the plant. The loss of a generating unit for an extended period would result in very costly replacement power and repair costs for any paper mill. As machine insulation systems age over decades, aging mechanisms progress to increase the risk of a possible ground fault internal to the generator. An IEEE/IAS Working Group Report [1,2,3,4] submitted in 2002 discusses grounding and ground fault protection for medium voltage generator stators, highlighting their merits and drawbacks. The report is intended as a guide for engineers installing new or upgrading existing generator systems to minimize industrial bus connected generator damage from stator ground faults. This paper discusses a most recent 13.8kV generator upgrade at a paper mill employing the hybrid grounding scheme and ground fault protection evaluated favorably by the IEEE/IAS Working Group. Project tasks are described in detail. Issues and difficulties encountered during the course of the generator grounding upgrade which were not mentioned in the Working Group Report are presented for reference.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 50 条
  • [21] Paper mill results on the application and implementation of high-temperature supercalendering of coated paper
    Zakaib, S
    Vyse, R
    Makinen, T
    [J]. TAPPI FINISHING & CONVERTING CONFERENCE AND TRADE FAIR, 1999, : 41 - 54
  • [22] Paper mill case study in safety improvements for generator on-line brush changing
    Moody, Douglas
    Custer, Gary
    [J]. IEEE CONFERENCE RECORD OF 2007 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2007, : 68 - +
  • [23] Application of polyaniline and polypyrrole composites for paper mill wastewater treatment
    Ghorbani, Mohsen
    Esfandian, Hossein
    Taghipour, Nastaran
    Katal, Reza
    [J]. DESALINATION, 2010, 263 (1-3) : 279 - 284
  • [24] THE APPLICATION OF STABILIZATION PONDS IN THE PURIFICATION OF PULP AND PAPER MILL WASTES
    GEHM, HW
    [J]. JOURNAL WATER POLLUTION CONTROL FEDERATION, 1963, 35 (09): : 1174 - 1180
  • [25] Evaluating land application of pulp and paper mill sludge: A review
    Turner, Tomi
    Wheeler, Rebecca
    Oliver, Ian W.
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 317
  • [26] Application of DIA-BIOFRINGE to the treatment of paper mill wastewater
    Murakami, Hisao
    Sone, Katsumi
    Takagawa, Yasuyuki
    [J]. Kami Pa Gikyoshi/Japan Tappi Journal, 2002, 56 (04): : 47 - 54
  • [27] Application of Hybrid Generator System in Smart Grid
    Kiang, Tan Hang
    Koon, Chua Hian
    Peng, Teh Siaw
    Rong, Lim Jun
    Jin, Tan Peng
    [J]. LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 686 - 692
  • [28] Hybrid Rotor Injection Scheme for a Doubly Fed Induction Generator
    Kaderbhai, Munir
    Yuvarajan, S.
    [J]. 2009 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS, 2009, : 19 - 22
  • [29] Application of a photovoltaic generator to mitigate steel mill voltage fluctuation problems
    Garcia, Norberto
    Angel Vargas, Miguel
    [J]. 2016 IEEE PES TRANSMISSION & DISTRIBUTION CONFERENCE AND EXPOSITION-LATIN AMERICA (PES T&D-LA), 2016,
  • [30] A review of constraints and opportunities for the land application of paper mill sludges and residues
    Drolet, JY
    Baril, P
    [J]. PULP & PAPER-CANADA, 1997, 98 (06) : 63 - 66