Ultrasensitive Determination of Vitamin B12 Using Disposable Graphite Screen-Printed Electrodes and Anodic Adsorptive Voltammetry

被引:18
|
作者
Michopoulos, Apostolos [1 ]
Florou, Ageliki B. [1 ]
Prodromidis, Mamas I. [1 ]
机构
[1] Univ Ioannina, Analyt Chem Lab, Ioannina 45100, Greece
关键词
Disposable sensors; Screen-printed electrodes; Vitamin B-12 (cyanocobalamin); Adsorptive voltammetry; Pharmaceutical products; ELECTROCHEMISTRY; LEAD; MECHANISM;
D O I
10.1002/elan.201500061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A facile, rapid and ultra-sensitive method for the determination of vitamin B-12 (cyanocobalamin) at the sub-nanomolar concentration range by using low-cost, disposable graphite screen-printed electrodes is described. The method is based on the cathodic preconcentration of square planar vitamin B-12s, as occurred due to the electro reduction of Co(III) center in vitamin B-12a to Co(I), at -1.3 V versus Ag/AgCl/3M KCl for 40 s. Then, an anodic square wave scan was applied and the height of the peak appeared at ca. -0.73 V versus Ag/AgCl/3 M KCl, due to the oxidation of Co(I) to Co(II) in the adsorbed molecule, was related to the concentration of the vitamin B-12 in the sample. EDTA was found to serve as a key-component of the electrolyte by eliminating the background signal caused by metal cations impurities contained in the electrolyte (0.1 M phosphate buffer in 0.1 M KCl, pH 3). It also blocks trace metals contained in real samples, thus eliminating their interference effect. The method was optimized to various working parameters and under the selected conditions the calibration curve was linear over the range 1 x 10(-10)-8 x 10(-9) mol L-1 vitamin B-12 (R-2 = 0.994), while the limit of detection for a signal-to-noise ratio of 3 (7 x 10(-11) mol L-1 vitamin B-12) is the lowest value of any reported in the literature for the electrochemical determination of vitamin B-12. The sensors were successfully applied to the determination of vitamin B-12 in pharmaceutical products.
引用
收藏
页码:1876 / 1882
页数:7
相关论文
共 50 条
  • [31] Simple Strategy for Selective Determination of Levamisole in Seized Cocaine and Pharmaceutical Samples Using Disposable Screen-printed Electrodes
    Rocha, Raquel G.
    Stefano, Jessica S.
    Arantes, Iana V. S.
    Ribeiro, Michelle M. A. C.
    Santana, Mario H. P.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2019, 31 (01) : 153 - 159
  • [32] Determination of total and electrolabile copper in agricultural soil by using disposable modified-carbon screen-printed electrodes
    Stéphane Faucher
    Cyril Cugnet
    Laurent Authier
    Gaëtane Lespes
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1249 - 1252
  • [33] Electrochemical detection of fentanyl with screen-printed carbon electrodes using square-wave adsorptive stripping voltammetry for forensic applications
    Ott, Colby E.
    Cunha-Silva, Hugo
    Kuberski, Sara L.
    Cox, Joseph A.
    Julia Arcos-Martinez, M.
    Arroyo-Mora, Luis E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 873
  • [34] Simple and Sensitive Determination of Sibutramine in Slimming Tea Beverages Using a Carbon Screen-printed Electrode with Adsorptive Stripping Voltammetry
    Lima, Amanda B.
    dos Santos, Wallans T. P.
    Compton, Richard G.
    ELECTROANALYSIS, 2019, 31 (05) : 975 - 980
  • [35] Determination of Sb(III) using an ex-situ bismuth screen-printed carbon electrode by adsorptive stripping voltammetry
    Rojas-Romo, Carlos
    Serrano, Nuria
    Arino, Cristina
    Arancibia, Veronica
    Manuel Diaz-Cruz, Jose
    Esteban, Miguel
    TALANTA, 2016, 155 : 21 - 27
  • [36] The Electrochemical Behavior of Nitrazepam at a Screen-Printed Carbon Electrode and Its Determination in Beverages by Adsorptive Stripping Voltammetry
    McGuire, Natasha D.
    Honeychurch, Kevin C.
    Hart, John P.
    ELECTROANALYSIS, 2009, 21 (19) : 2165 - 2170
  • [37] Development of a Portable Heavy Metal Ion Analyzer Using Disposable Screen-Printed Electrodes
    Choi, Hong Seok
    Kim, Hai Dong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (08): : 1881 - 1883
  • [38] DETERMINATION OF TRACE LEAD AND CADMIUM USING STRIPPING VOLTAMMETRY IN FLUIDIC MICROCHIP INTEGRATED WITH SCREEN-PRINTED CARBON ELECTRODES
    Fang, Hailin
    Tang, Fan
    Shi, Jianjun
    Zheng, Huxiang
    Bi, Lianhua
    Wang, Wei
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2012, 40 (06) : 590 - 602
  • [39] Disposable amperometric immunosensor for the detection of 17-β estradiol using screen-printed electrodes
    Butler, D
    Guilbault, GG
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 692 - 699
  • [40] Portable reconfigurable instrument for analytical determinations using disposable electrochemiluminescent screen-printed electrodes
    Carvajal, M. A.
    Ballesta-Claver, J.
    Morales, D. P.
    Palma, A. J.
    Valencia-Miron, M. C.
    Capitan-Vallvey, L. F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 169 : 46 - 53