Ultrasensitive Determination of Vitamin B12 Using Disposable Graphite Screen-Printed Electrodes and Anodic Adsorptive Voltammetry

被引:18
|
作者
Michopoulos, Apostolos [1 ]
Florou, Ageliki B. [1 ]
Prodromidis, Mamas I. [1 ]
机构
[1] Univ Ioannina, Analyt Chem Lab, Ioannina 45100, Greece
关键词
Disposable sensors; Screen-printed electrodes; Vitamin B-12 (cyanocobalamin); Adsorptive voltammetry; Pharmaceutical products; ELECTROCHEMISTRY; LEAD; MECHANISM;
D O I
10.1002/elan.201500061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A facile, rapid and ultra-sensitive method for the determination of vitamin B-12 (cyanocobalamin) at the sub-nanomolar concentration range by using low-cost, disposable graphite screen-printed electrodes is described. The method is based on the cathodic preconcentration of square planar vitamin B-12s, as occurred due to the electro reduction of Co(III) center in vitamin B-12a to Co(I), at -1.3 V versus Ag/AgCl/3M KCl for 40 s. Then, an anodic square wave scan was applied and the height of the peak appeared at ca. -0.73 V versus Ag/AgCl/3 M KCl, due to the oxidation of Co(I) to Co(II) in the adsorbed molecule, was related to the concentration of the vitamin B-12 in the sample. EDTA was found to serve as a key-component of the electrolyte by eliminating the background signal caused by metal cations impurities contained in the electrolyte (0.1 M phosphate buffer in 0.1 M KCl, pH 3). It also blocks trace metals contained in real samples, thus eliminating their interference effect. The method was optimized to various working parameters and under the selected conditions the calibration curve was linear over the range 1 x 10(-10)-8 x 10(-9) mol L-1 vitamin B-12 (R-2 = 0.994), while the limit of detection for a signal-to-noise ratio of 3 (7 x 10(-11) mol L-1 vitamin B-12) is the lowest value of any reported in the literature for the electrochemical determination of vitamin B-12. The sensors were successfully applied to the determination of vitamin B-12 in pharmaceutical products.
引用
收藏
页码:1876 / 1882
页数:7
相关论文
共 50 条
  • [21] Ionic Liquid-Carbon Nanotube Modified Screen-Printed Electrodes and Their Potential for Adsorptive Stripping Voltammetry
    Gan, Patrick
    Foord, John S.
    Compton, Richard G.
    ELECTROANALYSIS, 2014, 26 (09) : 1886 - 1892
  • [22] Disposable, acetylcholinesterase-coated, screen-printed carbon electrodes for the determination of organophosphorus pesticides
    Walter, Piotr
    Peplowski, Andrzej
    Gorski, Lukasz
    Janczak, Daniel
    Jakubowska, Malgorzata
    MICROELECTRONICS INTERNATIONAL, 2019, 36 (03) : 120 - 126
  • [23] Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodes
    Injang, Uthaitip
    Noyrod, Peeyanun
    Siangproh, Weena
    Dungchai, Wijitar
    Motomizu, Shoji
    Chailapakul, Orawon
    ANALYTICA CHIMICA ACTA, 2010, 668 (01) : 54 - 60
  • [24] On-site fuel electroanalysis: Determination of lead, copper and mercury in fuel bioethanol by anodic stripping voltammetry using screen-printed gold electrodes
    Almeida, Eduardo S.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ANALYTICA CHIMICA ACTA, 2014, 837 : 38 - 43
  • [25] Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
    Dominguez-Renedo, Olga
    Gomez Gonzalez, M. Jesus
    Julia Arcos-Martinez, M.
    SENSORS, 2009, 9 (01) : 219 - 231
  • [26] First Screen-Printed Sensor (Electrochemically Activated Screen-Printed Boron-Doped Diamond Electrode) for Quantitative Determination of Rifampicin by Adsorptive Stripping Voltammetry
    Kozak, Jedrzej
    Tyszczuk-Rotko, Katarzyna
    Wojciak, Magdalena
    Sowa, Ireneusz
    Rotko, Marek
    MATERIALS, 2021, 14 (15)
  • [27] Electrochemical determination of propranolol by using modified screen-printed electrodes
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Beitollahi, Hadi
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2020, 27 (01) : 73 - 78
  • [28] Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode
    Radi, Abd-Elgawad
    Khafagy, Amira
    El-shobaky, Amira
    El-mezayen, Hatem
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (02) : 132 - 136
  • [29] Anodic voltammetric determination of gemifloxacin using screen-printed carbon electrode
    Abd-Elgawad Radi
    Amira Khafagy
    Amira El-shobaky
    Hatem El-mezayen
    JournalofPharmaceuticalAnalysis, 2013, 3 (02) : 132 - 136
  • [30] Determination of total and electrolabile copper in agricultural soil by using disposable modified-carbon screen-printed electrodes
    Faucher, Stephane
    Cugnet, Cyril
    Authier, Laurent
    Lespes, Gaetane
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) : 1249 - 1252