A Fast and Low-cost Measuring System for Electrical Impedance Tomography

被引:0
|
作者
Mikulka, J. [1 ]
Dusek, J. [1 ]
Dedkova, J. [1 ]
Parilkova, J. [2 ]
Munsterova, Z. [2 ]
机构
[1] Brno Univ Technol, Fac Elect Engn & Commun, Dept Theoret & Expt Elect Engn, Brno, Czech Republic
[2] Brno Univ Technol, Inst Water Struct, Fac Civil Engn, Brno, Czech Republic
来源
2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING) | 2019年
关键词
D O I
10.1109/piers-spring46901.2019.9017338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) embodies a nondestructive, noninvasive method to estimate the conductivity distribution inside an object via measuring the surface voltage under simultaneous feeding with alternating current. The accuracy and speed of voltage measurement in the individual electrodes is a critical stage of the reconstruction as the most common, 16 electrode configuration requires 208 measuring cycles, including the current source switching. The paper discusses a designing procedure to produce a measuring card for an experimental tomograph, emphasizing measurement speed and accuracy as well as manufacturing costs reduction. Thus, the presented comparison of the card with various solutions relying on commercially available devices considers not only technical parameters but also overall cost. Importantly, the design approach consists in utilizing the MOSFET technology for galvanically isolated switching of the voltmeter or DAC electrodes and also current source switchovers. Each electrode is connected via 4 bidirectional switches (photocoupler) that replace mechanical relays. The employed Toshiba TLP3545A coupler exhibits the following characteristics: max open switch voltage - 60 V; max control LED current - 3 mA; max current when closed - 4 A; max resistance when closed - 60 m Omega; insulation voltage - 2.5 kV; min/max closed time 0.5/5 ms; min/max open time - 0.1/0.5 ms. All the parameters fundamentally determine the properties of the measuring card. The number of switches per electrode was chosen such that the card enables the user to connect the supply signal and the relevant measuring system to arbitrary dual polarity electrodes, facilitating simple measurement in adjacent, cross, polar, pseudo-polar, and other configurations.
引用
收藏
页码:3751 / 3755
页数:5
相关论文
共 50 条
  • [41] Design, realization and test of a low-cost electrical impedance spectrocopy analyzer for biological samples
    Zompanti, Alessandro
    Cicco, Riccardo
    Ciarrocchi, Davide
    Santonico, Marco
    Pennazza, Giorgio
    2023 9TH INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES, IWASI, 2023, : 86 - 90
  • [42] A low-cost electrical impedance analyser for interrogating self-sensing cement repairs
    McAlorum, Jack
    Vlachakis, Christos
    Perry, Marcus
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [43] A Measurement System for Electrical Impedance Tomography
    Kriz, T.
    Roubal, Z.
    Rez, J.
    PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 905 - 909
  • [44] BEYOND THE UNIVERSITY SYSTEM: LOW-COST RESEARCH, LOW-COST RESEARCHERS, LOW-COST FREEDOM
    Osipov, Alexander
    LABORATORIUM-RUSSIAN REVIEW OF SOCIAL RESEARCH, 2024, 16 (03): : 99 - 115
  • [45] A Low-Cost Method for Optical Tomography
    Erfanzadeh, Mohsen
    Alikhani, Saied
    Ansari, Mohammad Ali
    Mohajerani, Ezeddin
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2012, 3 (03) : 102 - 108
  • [46] SIMPLE, LOW-COST, FAST GALVANOSTAT
    GRIMNES, S
    CHEMICAL INSTRUMENTATION, 1973, 5 (02): : 141 - 144
  • [47] Design of a Portable Low-Cost Impedance Analyzer
    Al-Ali, Abdulwadood
    Elwakil, Ahmad
    Ahmad, Abdelaziz
    Maundy, Brent
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 1: BIODEVICES, 2017, : 104 - 109
  • [48] Low-Cost Impedance Controlled Multifinger Gripper
    Kubat, Mateusz
    Mianowski, Krzysztof
    Kmiecik, Piotr
    Granosik, Grzegorz
    2016 21ST INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2016, : 357 - 362
  • [49] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [50] FAST, NONLINEAR INVERSION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    LIONHEART, W
    PIDCOCK, M
    IMAGE AND VISION COMPUTING, 1994, 12 (06) : 367 - 373