A Fast and Low-cost Measuring System for Electrical Impedance Tomography

被引:0
|
作者
Mikulka, J. [1 ]
Dusek, J. [1 ]
Dedkova, J. [1 ]
Parilkova, J. [2 ]
Munsterova, Z. [2 ]
机构
[1] Brno Univ Technol, Fac Elect Engn & Commun, Dept Theoret & Expt Elect Engn, Brno, Czech Republic
[2] Brno Univ Technol, Inst Water Struct, Fac Civil Engn, Brno, Czech Republic
来源
2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING) | 2019年
关键词
D O I
10.1109/piers-spring46901.2019.9017338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) embodies a nondestructive, noninvasive method to estimate the conductivity distribution inside an object via measuring the surface voltage under simultaneous feeding with alternating current. The accuracy and speed of voltage measurement in the individual electrodes is a critical stage of the reconstruction as the most common, 16 electrode configuration requires 208 measuring cycles, including the current source switching. The paper discusses a designing procedure to produce a measuring card for an experimental tomograph, emphasizing measurement speed and accuracy as well as manufacturing costs reduction. Thus, the presented comparison of the card with various solutions relying on commercially available devices considers not only technical parameters but also overall cost. Importantly, the design approach consists in utilizing the MOSFET technology for galvanically isolated switching of the voltmeter or DAC electrodes and also current source switchovers. Each electrode is connected via 4 bidirectional switches (photocoupler) that replace mechanical relays. The employed Toshiba TLP3545A coupler exhibits the following characteristics: max open switch voltage - 60 V; max control LED current - 3 mA; max current when closed - 4 A; max resistance when closed - 60 m Omega; insulation voltage - 2.5 kV; min/max closed time 0.5/5 ms; min/max open time - 0.1/0.5 ms. All the parameters fundamentally determine the properties of the measuring card. The number of switches per electrode was chosen such that the card enables the user to connect the supply signal and the relevant measuring system to arbitrary dual polarity electrodes, facilitating simple measurement in adjacent, cross, polar, pseudo-polar, and other configurations.
引用
收藏
页码:3751 / 3755
页数:5
相关论文
共 50 条
  • [31] Low-cost multifrequency electrical impedance-based system (MFEIBS) for clinical imaging: design and performance evaluation
    Singh G.
    Anand S.
    Lall B.
    Srivastava A.
    Singh V.
    Singh, Gurmeet (gurmeetji@gmail.com), 2018, Taylor and Francis Ltd. (42): : 274 - 289
  • [32] Imaging fast electrical activity in the brain with electrical impedance tomography
    Aristovich, Kirill Y.
    Packham, Brett C.
    Koo, Hwan
    dos Santos, Gustavo Sato
    McEvoy, Andy
    Holder, David S.
    NEUROIMAGE, 2016, 124 : 204 - 213
  • [33] Low-cost intelligent surveillance system based on fast CNN
    Sabri, Zaid Saeb
    Li, Zhiyong
    PEERJ COMPUTER SCIENCE, 2021,
  • [35] A low-cost lighting system for fast line scan cameras
    Kim, HG
    Lim, YJ
    Kim, KO
    Kim, HS
    6TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL IX, PROCEEDINGS: IMAGE, ACOUSTIC, SPEECH AND SIGNAL PROCESSING II, 2002, : 125 - 128
  • [36] Low-cost intelligent surveillance system based on fast CNN
    Sabri Z.S.
    Li Z.
    PeerJ Computer Science, 2021, 7 : 1 - 23
  • [37] Fast and Low-cost Mechatronic Recognition System for Persian Banknotes
    Behjat, Majid
    Moallem, Payman
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2014, 11
  • [38] A smart, low-cost AC charging system for electrical vehicles
    Ju Xiaoping
    2013 5TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS (PESA), 2013,
  • [39] Fast and Low-Cost Online Detection of Critical Micelle Concentration based on Impedance Spectroscopy
    Gruden, Roman
    Kanoun, Olfa
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 135 - 140
  • [40] MEASURING NANOVOLTS WITH LOW-COST DVMS
    SCHOWENG.RN
    INSTRUMENTS & CONTROL SYSTEMS, 1972, 45 (03): : 115 - &