Investigation on current transformers for measuring of electron beam pulse current

被引:1
|
作者
Nanthanasit, P. [1 ,2 ,3 ]
Rimjaem, S. [1 ,3 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Phys & Mat Sci, Plasma & Beam Phys Res Facil, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Fac Sci, Dept Phys & Mat Sci, PhD Program Phys,Internat Program, Chiang Mai 50200, Thailand
[3] Thailand Ctr Excellence Phys, Commiss Higher Educ, Bangkok 10400, Thailand
关键词
D O I
10.1088/1742-6596/1380/1/012149
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The radio-frequency (RF) linear accelerator (linac) system of the PBP-CMU Electron Linac Laboratory at the Plasma and Beam Physics Research Facility is used as an injector system for future mid-infrared and terahertz free-electron lasers. The properties of electron beams produced from the linac must be controlled appropriately to produce high-quality radiation. One of the most important properties is the electron pulse current that can be measured using a current transformer. A copper wire with proper insulator is wounded around the ferrite-core forming a secondary coil of the current transformer. The electron beam passing through the transformer acts as the current in the primary coil and it induces an electromotive force in the secondary coil. Therefore, the output signal from the secondary coil can be measured and analyzed to be a pulse current of electron beam. The measured current pulse shape and value strongly depend on the characteristics of the current transformer. This study focuses on testing and calibrating of existing current transformers installed in the linac system. In the experiments, the pulse generator was used to generate the input pulse current with various pulse lengths. The output pulses were then sampled with a digital oscilloscope. The experimental results showed that the output pulses from the current transformers have distort shape compared with the input pulses. Consequently, the correction was conducted to provide more accuracy of the measuring value of the electron pulse current. The results of this research can be used as a valuable database for the existing current transformers and to develop the new ones that can provide more accurate results.
引用
收藏
页数:5
相关论文
共 50 条
  • [42] HARP, A SHORT PULSE, HIGH-CURRENT ELECTRON-BEAM ACCELERATOR
    PRESTWICH, KR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (03) : 975 - 978
  • [43] Electron beam-induced current investigation of GaN Schottky diode
    Matoussi, A
    Boufaden, T
    Guermazi, S
    Mlik, Y
    El Jani, B
    Toureille, A
    JOURNAL OF ELECTRONIC MATERIALS, 2005, 34 (07) : 1059 - 1064
  • [44] Electron beam-induced current investigation of GaN Schottky diode
    A. Matoussi
    T. Boufaden
    S. Guermazi
    Y. Mlik
    B. El Jani
    A. Toureille
    Journal of Electronic Materials, 2005, 34 : 1059 - 1064
  • [45] Investigation of nitride films by the electron-beam-induced current method
    Yakimov E.B.
    Journal of Surface Investigation, 2015, 9 (05): : 939 - 943
  • [46] CURRENT TRANSFORMERS
    CROSS, RC
    AMERICAN JOURNAL OF PHYSICS, 1986, 54 (12) : 1110 - 1113
  • [47] A NANOSECOND ELECTRON PULSE CURRENT MONITOR
    MCDONALD, J
    WEISS, H
    PINKERTO.A
    EPP, ER
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 140 - &
  • [48] PULSE MEASURING TRANSFORMER OF NANOSECOND RANGE CURRENT
    IVANOV, BI
    MIROSHNI.VA
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (05): : 138 - 140
  • [49] Functional Measuring Generator with Pulse Current Stabilization
    Galiev, A. L.
    Yumagulov, N., I
    Topolsky, D., V
    2020 GLOBAL SMART INDUSTRY CONFERENCE (GLOSIC), 2020, : 259 - 264
  • [50] Study of novel CT for measuring pulse current
    Huang, SY
    Li, WB
    Yin, XG
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 1237 - 1241