Investigation on current transformers for measuring of electron beam pulse current

被引:1
|
作者
Nanthanasit, P. [1 ,2 ,3 ]
Rimjaem, S. [1 ,3 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Phys & Mat Sci, Plasma & Beam Phys Res Facil, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Fac Sci, Dept Phys & Mat Sci, PhD Program Phys,Internat Program, Chiang Mai 50200, Thailand
[3] Thailand Ctr Excellence Phys, Commiss Higher Educ, Bangkok 10400, Thailand
关键词
D O I
10.1088/1742-6596/1380/1/012149
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The radio-frequency (RF) linear accelerator (linac) system of the PBP-CMU Electron Linac Laboratory at the Plasma and Beam Physics Research Facility is used as an injector system for future mid-infrared and terahertz free-electron lasers. The properties of electron beams produced from the linac must be controlled appropriately to produce high-quality radiation. One of the most important properties is the electron pulse current that can be measured using a current transformer. A copper wire with proper insulator is wounded around the ferrite-core forming a secondary coil of the current transformer. The electron beam passing through the transformer acts as the current in the primary coil and it induces an electromotive force in the secondary coil. Therefore, the output signal from the secondary coil can be measured and analyzed to be a pulse current of electron beam. The measured current pulse shape and value strongly depend on the characteristics of the current transformer. This study focuses on testing and calibrating of existing current transformers installed in the linac system. In the experiments, the pulse generator was used to generate the input pulse current with various pulse lengths. The output pulses were then sampled with a digital oscilloscope. The experimental results showed that the output pulses from the current transformers have distort shape compared with the input pulses. Consequently, the correction was conducted to provide more accuracy of the measuring value of the electron pulse current. The results of this research can be used as a valuable database for the existing current transformers and to develop the new ones that can provide more accurate results.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Investigation of the formation of the secondary current signal in plasma in electron beam welding with oscillations of the electron beam
    Trushnikov, D.N.
    Belen'kii, V. Ya
    Welding International, 2013, 27 (11) : 877 - 880
  • [22] CURRENT PULSE MEASURING SYSTEM.
    Anon
    IBM technical disclosure bulletin, 1985, 28 (06): : 2739 - 2741
  • [23] INSTRUMENTATION CURRENT PULSE TRANSFORMERS FOR THE NANOSECOND RANGE.
    Ivanov, B.I.
    Miroshnichenko, V.A.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1973, 16 (5 Part 2): : 1457 - 1460
  • [24] Design and implementation of high-current pulse measuring device for real-time FLASH electron beam monitoring
    Kyoung Won Jang
    Manwoo Lee
    Heuijin Lim
    Sang Koo Kang
    Sang Jin Lee
    Hyun Kim
    Dong Hyeok Jeong
    Journal of the Korean Physical Society, 2023, 83 : 121 - 125
  • [25] Design and implementation of high-current pulse measuring device for real-time FLASH electron beam monitoring
    Jang, Kyoung Won
    Lee, Manwoo
    Lim, Heuijin
    Kang, Sang Koo
    Lee, Sang Jin
    Kim, Hyun
    Jeong, Dong Hyeok
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 83 (02) : 121 - 125
  • [26] A method of extending the checking range of measuring current transformers
    Nefed'ev, D. I.
    MEASUREMENT TECHNIQUES, 2006, 49 (04) : 391 - 394
  • [27] A method of extending the checking range of measuring current transformers
    D. I. Nefed’ev
    Measurement Techniques, 2006, 49 : 391 - 394
  • [28] Modeling of measuring current and voltage transformers in dynamic modes
    Lebedev, Vladimir
    Shuin, Vladimir
    Yablokov, Andrey
    Filatova, Galina
    2014 INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, AUTOMATION AND CONTROL SYSTEMS (MEACS), 2014,
  • [29] MEASURING ACCURACY OF HEAVY-CURRENT INSTRUMENT TRANSFORMERS
    ERB, W
    BROWN BOVERI REVIEW, 1972, 59 (2-3): : 122 - &
  • [30] Electron beam current meter
    Volodarskij, V.V.
    Muminov, T.M.
    Potapov, Yu.V.
    Usmanov, R.R.
    Pribory i Tekhnika Eksperimenta, 1991, (02): : 229 - 230