Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography

被引:41
|
作者
Tapfer, Arne [1 ,2 ]
Bech, Martin [1 ,2 ]
Pauwels, Bart [3 ]
Liu, Xuan [3 ]
Bruyndonckx, Peter [3 ]
Sasov, Alexander [3 ]
Kenntner, Johannes [4 ]
Mohr, Juergen [4 ]
Walter, Marco [5 ]
Schulz, Joachim [5 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, D-85748 Garching, Germany
[3] SkyScan, B-2550 Kontich, Belgium
[4] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
[5] Microworks, D-76137 Karlsruhe, Germany
基金
欧洲研究理事会;
关键词
x-ray imaging; phase contrast; computed tomography; micro-computed tomography;
D O I
10.1118/1.3644844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. Methods: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient mu and decrement delta of the complex refractive index. Theoretical values of mu and delta were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. Results: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of mu and delta. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. Conclusions: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3644844]
引用
收藏
页码:5910 / 5915
页数:6
相关论文
共 50 条
  • [31] Neodymium acetate as a contrast agent for X-ray phase-contrast tomography
    Reichmann, Jakob
    Ruhwedel, Torben
    Moebius, Wiebke
    Salditt, Tim
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (05)
  • [32] Neodymium acetate as a contrast agent for X-ray phase-contrast tomography
    Reichmann, Jakob
    Ruhwedel, Torben
    Moebius, Wiebke
    Salditt, Tim
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [33] X-ray phase-contrast tomography of porcine fat and rind
    Jensen, Torben H.
    Boettiger, Arvid
    Bech, Martin
    Zanette, Irene
    Weitkamp, Timm
    Rutishauser, Simon
    David, Christian
    Reznikova, Elena
    Mohr, Juergen
    Christensen, Lars Bager
    Olsen, Eli V.
    Feidenhans'l, Robert
    Pfeiffer, Franz
    MEAT SCIENCE, 2011, 88 (03) : 379 - 383
  • [34] Phase retrieval in X-ray phase-contrast imaging suitable for tomography
    Burvall, Anna
    Lundstrom, Ulf
    Takman, Per A. C.
    Larsson, Daniel H.
    Hertz, Hans M.
    OPTICS EXPRESS, 2011, 19 (11): : 10359 - 10376
  • [35] Phase-Contrast Tomography with X-ray Hartmann wavefront sensor
    Provinciali, Ginevra Begani
    Cedola, Alessia
    de la Rochefoucauld, Ombeline
    Zeitoun, Philippe
    INTERNATIONAL CONFERENCE ON X-RAY LASERS 2020, 2021, 11886
  • [36] X-ray Phase-Contrast Radiography and Tomography with a Multiaperture Analyzer
    Endrizzi, M.
    Vittoria, F. A.
    Rigon, L.
    Dreossi, D.
    Iacoviello, F.
    Shearing, P. R.
    Olivo, A.
    PHYSICAL REVIEW LETTERS, 2017, 118 (24)
  • [37] Imaging and density mapping of tetrahydrofuran clathrate hydrates by phase-contrast x-ray computed tomography
    Takeya, Satoshi
    Honda, Kazumasa
    Kawamura, Taro
    Yamamoto, Yoshitaka
    Yoneyama, Akio
    Hirai, Yasuharu
    Hyodo, Kazuyuki
    Takeda, Tohoru
    APPLIED PHYSICS LETTERS, 2007, 90 (08)
  • [38] Analysis and accurate reconstruction of incomplete data in X-ray differential phase-contrast computed tomography
    Jian Fu
    Renbo Tan
    Liyuan Chen
    Analytical and Bioanalytical Chemistry, 2014, 406 : 897 - 904
  • [39] In-line X-ray phase-contrast computerized tomography
    National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
    Guangxue Xuebao, 2008, 3 (609-612):
  • [40] X-ray computed tomography of wood-adhesive bondlines: attenuation and phase-contrast effects
    Paris, Jesse L.
    Kamke, Frederick A.
    Xiao, Xianghui
    WOOD SCIENCE AND TECHNOLOGY, 2015, 49 (06) : 1185 - 1208