Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography

被引:41
|
作者
Tapfer, Arne [1 ,2 ]
Bech, Martin [1 ,2 ]
Pauwels, Bart [3 ]
Liu, Xuan [3 ]
Bruyndonckx, Peter [3 ]
Sasov, Alexander [3 ]
Kenntner, Johannes [4 ]
Mohr, Juergen [4 ]
Walter, Marco [5 ]
Schulz, Joachim [5 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, D-85748 Garching, Germany
[3] SkyScan, B-2550 Kontich, Belgium
[4] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
[5] Microworks, D-76137 Karlsruhe, Germany
基金
欧洲研究理事会;
关键词
x-ray imaging; phase contrast; computed tomography; micro-computed tomography;
D O I
10.1118/1.3644844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. Methods: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient mu and decrement delta of the complex refractive index. Theoretical values of mu and delta were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. Results: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of mu and delta. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. Conclusions: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3644844]
引用
收藏
页码:5910 / 5915
页数:6
相关论文
共 50 条
  • [21] Speckle tracking phase-contrast computed tomography at an inverse Compton X-ray source
    Zandarco, Simon
    Guenther, Enedikt
    Riedel, Mirko
    Breitenhuber, Gregor
    Kirst, Miriam
    Achterhold, Klaus
    Pfeiffer, Franz
    Herzen, Julia
    OPTICS EXPRESS, 2024, 32 (16): : 28472 - 28488
  • [22] Visualization of microvasculature and thrombi by X-ray phase-contrast computed tomography in hepatocellular carcinoma
    Jian, Jianbo
    Yang, Hao
    Zhao, Xinyan
    Xuan, Ruijiao
    Zhang, Yujie
    Li, Dongyue
    Hu, Chunhong
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 600 - 605
  • [23] Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography
    Massimi, Lorenzo
    Suaris, Tamara
    Hagen, Charlotte K.
    Endrizzi, Marco
    Munro, Peter R. T.
    Havariyoun, Glafkos
    Hawker, P. M. Sam
    Smit, Bennie
    Astolfo, Alberto
    Larkin, Oliver J.
    Waltham, Richard M.
    Shah, Zoheb
    Duffy, Stephen W.
    Nelan, Rachel L.
    Peel, Anthony
    Jones, J. Louise
    Haig, Ian G.
    Bate, David
    Olivo, Alessandro
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] A minute fossil phoretic mite recovered by phase-contrast X-ray computed tomography
    Dunlop, Jason A.
    Wirth, Stefan
    Penney, David
    McNeil, Andrew
    Bradley, Robert S.
    Withers, Philip J.
    Preziosi, Richard F.
    BIOLOGY LETTERS, 2012, 8 (03) : 457 - 460
  • [25] An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography
    Fu, Jian
    Schleede, Simone
    Tan, Renbo
    Chen, Liyuan
    Bech, Martin
    Achterhold, Klaus
    Gifford, Martin
    Loewen, Rod
    Ruth, Ronald
    Pfeiffer, Franz
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 186 - 193
  • [26] In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography
    Sunaguchi, Naoki
    Yuasa, Tetsuya
    Hirano, Shin-ichi
    Gupta, Rajiv
    Ando, Masami
    PLOS ONE, 2015, 10 (08):
  • [27] Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography
    Lorenzo Massimi
    Tamara Suaris
    Charlotte K. Hagen
    Marco Endrizzi
    Peter R. T. Munro
    Glafkos Havariyoun
    P. M. Sam Hawker
    Bennie Smit
    Alberto Astolfo
    Oliver J. Larkin
    Richard M. Waltham
    Zoheb Shah
    Stephen W. Duffy
    Rachel L. Nelan
    Anthony Peel
    J. Louise Jones
    Ian G. Haig
    David Bate
    Alessandro Olivo
    Scientific Reports, 11
  • [28] Testicular seminoma in the aged rat visualized by phase-contrast X-ray computed tomography
    Thet-Thet-Lwin
    Yoneyama, Akio
    Imai, Motoki
    Maruyama, Hiroko
    Hyodo, Kazuyuki
    Takeda, Tohoru
    ACTA RADIOLOGICA OPEN, 2018, 7 (10):
  • [29] Phase-contrast X-ray tomography: Contrast mechanism and roles of phase retrieval
    Wu, Xizeng
    Liu, Hong
    Yan, Amin
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S8 - S12
  • [30] Contrast Detail Phantoms for X-ray Phase-Contrast Mammography and Tomography
    Bliznakova, Kristina
    Mettivier, Giovanni
    Russo, Paolo
    Buliev, Ivan
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 611 - 617