Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography

被引:41
|
作者
Tapfer, Arne [1 ,2 ]
Bech, Martin [1 ,2 ]
Pauwels, Bart [3 ]
Liu, Xuan [3 ]
Bruyndonckx, Peter [3 ]
Sasov, Alexander [3 ]
Kenntner, Johannes [4 ]
Mohr, Juergen [4 ]
Walter, Marco [5 ]
Schulz, Joachim [5 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, D-85748 Garching, Germany
[3] SkyScan, B-2550 Kontich, Belgium
[4] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
[5] Microworks, D-76137 Karlsruhe, Germany
基金
欧洲研究理事会;
关键词
x-ray imaging; phase contrast; computed tomography; micro-computed tomography;
D O I
10.1118/1.3644844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. Methods: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient mu and decrement delta of the complex refractive index. Theoretical values of mu and delta were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. Results: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of mu and delta. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. Conclusions: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3644844]
引用
收藏
页码:5910 / 5915
页数:6
相关论文
共 50 条
  • [1] Recent observations with phase-contrast X-ray computed tomography
    Momose, A
    Takeda, T
    Itai, Y
    Tu, JH
    Hirano, K
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 188 - 195
  • [2] Helical differential X-ray phase-contrast computed tomography
    Fu, Jian
    Willner, Marian
    Chen, Liyuan
    Tan, Renbo
    Achterhold, Klaus
    Bech, Martin
    Herzen, Julia
    Kunka, Danays
    Mohr, Juergen
    Pfeiffer, Franz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 374 - 379
  • [3] Phase-contrast X-ray computed tomography for biological imaging
    Momose, A
    Takeda, T
    Itai, Y
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 120 - 129
  • [4] X-ray phase-contrast tomography
    Bushuev, VA
    Ingal, VN
    Beliaevskaya, EA
    Sergeev, AA
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2002, 24 (04): : 559 - 569
  • [5] Observation of human tissues with phase-contrast X-ray computed tomography
    Momose, A
    Takeda, T
    Itai, Y
    Tu, JH
    Hirano, K
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 365 - 374
  • [6] Quantitative X-ray phase-contrast computed tomography at 82 keV
    Willner, Marian
    Bech, Martin
    Herzen, Julia
    Zanette, Irene
    Hahn, Dieter
    Kenntner, Johannes
    Mohr, Juergen
    Rack, Alexander
    Weitkamp, Timm
    Pfeiffer, Franz
    OPTICS EXPRESS, 2013, 21 (04): : 4155 - 4166
  • [7] Noise propagation in x-ray phase-contrast imaging and computed tomography
    Nesterets, Yakov I.
    Gureyev, Timur E.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (10)
  • [8] X-ray Phase-Contrast Computed Tomography of Human Coronary Arteries
    Hetterich, Holger
    Willner, Marian
    Habbel, Christopher
    Herzen, Julia
    Hoffmann, Verena S.
    Fill, Sandra
    Hipp, Alexander
    Marschner, Mathias
    Schueller, Ulrich
    Auweter, Sigrid
    Massberg, Steffen
    Reiser, Maximilian F.
    Pfeiffer, Franz
    Saam, Tobias
    Bamberg, Fabian
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 686 - 694
  • [9] Helical X-ray phase-contrast computed tomography without phase stepping
    M. Marschner
    M. Willner
    G. Potdevin
    A. Fehringer
    P. B. Noël
    F. Pfeiffer
    J. Herzen
    Scientific Reports, 6
  • [10] Improvement of spatial resolution in phase-contrast X-ray computed tomography
    Momose, A
    Koyama, I
    Hirano, K
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 71 - 81