DOSES TO OPERATORS DURING INTERVENTIONAL RADIOLOGY PROCEDURES: FOCUS ON EYE LENS AND EXTREMITY DOSIMETRY

被引:53
|
作者
Koukorava, C. [1 ,2 ]
Carinou, E. [1 ]
Simantirakis, G. [1 ,2 ]
Vrachliotis, T. G. [3 ]
Archontakis, E. [4 ]
Tierris, C. [3 ]
Dimitriou, P. [2 ]
机构
[1] GAEC, Athens 15310, Greece
[2] Univ Athens, Sch Med, Dept Med Phys, GR-11527 Athens, Greece
[3] Henry Dunant Hosp, Athens 11526, Greece
[4] Red Cross Hosp, Athens, Greece
关键词
RADIATION-EXPOSURE; PATIENT;
D O I
10.1093/rpd/ncq328
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study is focused on the personnel doses during several types of interventional radiology procedures. Apart from the use of the official whole body dosemeters (thermoluminescence dosemeter type), measurements were performed to the extremities and the eyes using thermoluminescent loose pellets. The mean doses per kerma area product were calculated for the monitored anatomic regions and for the most frequent types of procedures. Higher dose values were measured during therapeutic procedures, especially embolisations. The maximum recorded doses during a single procedure were 1.8 mSv to the finger (nephrostomy), 2.1 mSv to the wrist (liver chemoembolisation), 0.6 mSv to the leg (brain embolisation) and 2.4 mSv to the eye (brain embolisation). The annual doses estimated for the operator with the highest workload according to the measurements and the system's log book were 90.4 mSv to the finger, 107.9 mSv to the wrist, 21.6 mSv to the leg and 49.3 mSv to the eye. Finally, the effect of the beam angulation (i.e. projection) and shielding equipment on the personnel doses was evaluated. The measurements were performed within the framework of the ORAMED (Optimization of RAdiation Protection for MEDical staff) project.
引用
收藏
页码:482 / 486
页数:5
相关论文
共 50 条
  • [21] Eye Lens Dosimetry in Interventional Radiology: Assessment With Dedicated Hp(3) Dosimeters
    Merrachi, Nassim-Albert
    Bouchard-Bellavance, Roxanne
    Perreault, Pierre
    Gilbert, Patrick
    Soulez, Gilles
    Bouchard, Louis
    Oliva, Vincent L.
    Giroux, Marie-France
    Normandeau, Lysanne
    Therasse, Eric
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2021, 72 (02): : 317 - 323
  • [22] Ratios of Eye Lens and Hand Equivalent Doses with Whole-Body Effective Doses for Operators Performing Interventional Radiological Procedures
    Tsai, Wan-Chih
    Chu, Wei-Han
    Sheu, Rong-Jiun
    HEALTH PHYSICS, 2022, 123 (03): : 257 - 264
  • [23] Eye Lens Doses Received by Radiation Workers in Interventional Medical Procedures
    Hiswara, E.
    Kartikasari, D.
    Sofyan, H.
    Nuraeni, N.
    Sandy, Kyp
    ATOM INDONESIA, 2020, 46 (03) : 135 - 140
  • [24] Radiation dose to physicians' eye lens during interventional radiology
    Bahruddin, N. A.
    Hashim, S.
    Karim, M. K. A.
    Sabarudin, A.
    Ang, W. C.
    Salehhon, N.
    Bakar, K. A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [25] Surgeon eye lens dose monitoring in interventional neuroradiology, cardiovascular and radiology procedures
    Busoni, S.
    Bruzzi, M.
    Giomi, S.
    Poggiali, C.
    Quattrocchi, M.
    Betti, M.
    D'Urso, D.
    Fedeli, L.
    Mazzoni, L. N.
    Paolucci, M.
    Rossi, F.
    Taddeucci, A.
    Bettarini, S.
    Tortoli, P.
    Belli, G.
    Bernardi, L.
    Gasperi, C.
    Campanella, F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 123 - 128
  • [26] Extremity and eye lens dosimetry for medical staff performing vertebroplasty and kyphoplasty procedures
    Struelens, L.
    Schoonjans, W.
    Schils, F.
    De Smedt, K.
    Vanhavere, F.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 635 - 645
  • [27] Assessment of Occupational Exposure to Eye Lens Dosimetry for Interventional Radiology Workers in China during 2017-2019
    Li, Mengxue
    Fan, Shengnan
    Zhang, Xianpeng
    Hao, Shuxia
    Zhao, Yu
    Deng, Jun
    Sun, Quanfu
    HEALTH PHYSICS, 2022, 123 (03): : 229 - 237
  • [28] OPTIMIZATION OF A RADIOPHOTOLUMINESCENT GLASS DOSEMETER FOR OCCUPATIONAL EYE LENS DOSIMETRY IN INTERVENTIONAL RADIOLOGY/CARDIOLOGY
    Silva, Edilaine H.
    Struelens, Lara
    Covens, Peter
    Ueno, Satoshi
    Koguchi, Yasuhiro
    Vanhavere, Filip
    Buls, Nico
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 177 - 183
  • [29] CORRELATION OF EYE LENS DOSES AND PERSONAL DOSE EQUIVALENT MEASURED ON THE ARM OF INTERVENTIONAL CARDIOLOGISTS FOR A RETROSPECTIVE ASSESSMENT OF DOSES TO OPERATORS' EYE LENS
    Domienik-Andrzejewska, Joanna
    Brodecki, Marcin
    Zmyslony, Marek
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (03) : 271 - 278
  • [30] Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project
    Vanhavere, F.
    Carinou, E.
    Domienik, J.
    Donadille, L.
    Ginjaume, M.
    Gualdrini, G.
    Koukorava, C.
    Krim, S.
    Nikodemova, D.
    Ruiz-Lopez, N.
    Sans-Merce, M.
    Struelens, L.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1243 - 1247