Evaluation of detection and sample clean-up techniques for on- and off-line fermentation monitoring systems

被引:14
|
作者
Buttler, T [1 ]
Liden, H [1 ]
Jonsson, JA [1 ]
Gorton, L [1 ]
MarkoVarga, G [1 ]
Jeppsson, H [1 ]
机构
[1] LUND UNIV,LUND INST TECHNOL,DEPT APPL MICROBIOL,S-22100 LUND,SWEDEN
关键词
biosensors; fermentation processes; carbohydrates; microdialysis; sample clean-up;
D O I
10.1016/0003-2670(96)00024-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different analytical systems for monitoring of fermentation processes were evaluated for the analysis of three carbohydrates: glucose, xylose and galactose. Samples taken during a controlled fermentation of the three sugars to ethanol were treated and analysed with both systems for the carbohydrate content. The first was an off-line system, based on manual sampling and clean-up, and column liquid chromatography (LC) in combination with refractive index (RI) detection and the other was an on-line set-up, based on microdialysis sampling, LC and an amperometric carbohydrate biosensor as the detection device. The manual clean-up consisted of centrifugation, filtration of the supernatant and dilution. First, the different clean-up procedures were compared, and the other parts of the system were kept constant, viz. the LC separation and the RI detector, Evaluation of the analysis response using the two clean-up procedures yielded in 12 of 13 cases higher values for the microdialysis probe than for the manual procedure. Two different statistical methods, one based on linear regression and another, a paired t-test, found the difference between the two clean-up procedures to be statistically significant. Detailed investigation of the manual clean-up procedure using analysis of variance (ANOVA) revealed that for identical samples treated by this method, a significant difference in-between the samples after treatment was found. Next, the two detection techniques were compared, using the manual clean-up procedure in combination with LC. It was found that the sugar content in 15 out of 16 samples was higher for the RI detector than for the biosensor and also in this case both the linear regression method and the paired t-test showed the difference to be statistically significant. Finally, studies on the performance of microdialysis probe membranes after use in a fermentation medium are presented.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 50 条
  • [41] Debonding and Clean-Up in Orthodontics: Evaluation of Different Techniques and Micro-Morphological Aspects of the Enamel Surface
    D'Amario, Maurizio
    Bernardi, Sara
    Di Lauro, Daniele
    Marzo, Giuseppe
    Macchiarelli, Guido
    Capogreco, Mario
    [J]. DENTISTRY JOURNAL, 2020, 8 (02)
  • [42] Determination of PAH in food samples by HPLC with fluorimetric detection following sonication extraction without sample clean-up
    Nieva-Cano, MJ
    Rubio-Barroso, S
    Santos-Delgado, MJ
    [J]. ANALYST, 2001, 126 (08) : 1326 - 1331
  • [43] Determination of ammonia in wastewaters containing high concentrations of surfactants by flow injection potentiometry with on-line sample clean-up
    Shen, HD
    Cardwell, TJ
    Cattrall, RW
    [J]. ANALYTICA CHIMICA ACTA, 1998, 367 (1-3) : 193 - 199
  • [44] Sensitive, high throughput HPLC-MS/MS method with on-line sample clean-up for everolimus measurement
    Korecka, Magdalena
    Solari, Sandra G.
    Shaw, Leslie M.
    [J]. THERAPEUTIC DRUG MONITORING, 2006, 28 (04) : 484 - 490
  • [45] PERFORMANCE EVALUATION OF SOME METHODS FOR OFF-LINE DETECTION OF CHANGES IN AUTOREGRESSIVE SIGNALS - COMMENTS
    COATES, D
    [J]. SIGNAL PROCESSING, 1991, 24 (03) : 353 - 357
  • [46] IN-DIE ULTRASONIC AND OFF-LINE AIR-COUPLED MONITORING AND CHARACTERIZATION TECHNIQUES FOR DRUG TABLETS
    Stephens, J. D.
    Kowalczyk, B. R.
    Hancock, B. C.
    Kaul, G.
    Akseli, I.
    Cetinkaya, C.
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 31A AND 31B, 2012, 1430 : 1691 - 1698
  • [47] Performance evaluation of production systems monitored by statistical process control and off-line inspections
    Colledani, Marcello
    Tolio, Tullio
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2009, 120 (02) : 348 - 367
  • [48] Integrated on-line sample clean-up using cation exchange restricted access sorbent for the LC determination of atropine in human plasma coupled to UV detection
    Rbeida, O
    Christiaens, B
    Hubert, P
    Lubda, D
    Boos, KS
    Crommen, J
    Chiap, P
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 36 (05) : 947 - 954
  • [49] Characteristics of on-line and off-line partial discharge on hydrogenerator stator windings using acoustic emission detection techniques
    Kaneko, T
    Ueda, T
    Takenouchi, O
    Otsubo, M
    Honda, C
    Tsuruta, Y
    Fukura, A
    Tanaka, K
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 837 - 840
  • [50] Quality assurance of onboard megavoltage computed tomography imaging and target localization systems for on- and off-line image-guided radiotherapy
    Langen, Katja M.
    Meeks, Sanford L.
    Pouliot, Jean
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S62 - S65