Determination of ammonia in wastewaters containing high concentrations of surfactants by flow injection potentiometry with on-line sample clean-up

被引:12
|
作者
Shen, HD [1 ]
Cardwell, TJ [1 ]
Cattrall, RW [1 ]
机构
[1] La Trobe Univ, Sch Chem, Ctr Sci Instrumentat, Bundoora, Vic 3083, Australia
基金
澳大利亚研究理事会;
关键词
ammonia; surfactants; wastewaters; flow injection; activated carbon; potentiometry; nonactin electrode;
D O I
10.1016/S0003-2670(98)00168-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is demonstrated that surfactants lead to problems in the analysis of ammonia in gas-diffusion flow injection by wetting the membrane to allow transport of potentially interfering species to the detector. An on-line clean-up procedure, involving use of an activated carbon cartridge, is described for the removal of ionic and non-ionic surfactants (up to 1000 mg l(-1)) and other organic compounds from aqueous samples. Ammoniacal nitrogen was determined in synthetic samples by gas-diffusion flow injection with a nonactin-based potentiometric sensor used as the detector for the ammonium ion. Analyses could be performed at a sampling rate of ca. 25 h(-1) and the cartridge was effective for at least 1000 injections of 50 mu l samples in the concentration range 1-180 mg l(-1). The procedure was applied to the analysis of wastewaters and was found to be efficient in removing ionic and non-ionic surfactants from acidified (pH 1) samples. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 50 条
  • [1] Graphite furnace atomic absorption spectrometric determination of some noble metals using flow injection on-line clean-up
    Su, XG
    Wang, MJ
    Zhang, YH
    Zhang, JH
    Zhang, HQ
    Jin, QH
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) : 1341 - 1343
  • [2] On-line electrophoretic sample clean-up for sensitive and reproducible μCE immunoassay
    Pan, Qiong
    Hong, Soongweon
    Zhu, Xiaocui
    Zhao, Meiping
    Lee, Luke P.
    [J]. LAB ON A CHIP, 2012, 12 (05) : 932 - 938
  • [3] Capillary zone electrophoresis with on-line isotachophoretic sample pretreatment: Sample clean-up aspects
    Kaniansky, Dusan
    Marak, Jozef
    Lastinec, Jan
    Reijenga, Jetse C.
    Onuska, Francis I.
    [J]. Journal of Microcolumn Separations, 11 (02): : 141 - 153
  • [4] Capillary zone electrophoresis with on-line isotachophoretic sample pretreatment:: Sample clean-up aspects
    Kaniansky, D
    Marák, J
    Lastinec, J
    Reijenga, JC
    Onuska, FI
    [J]. JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (02) : 141 - 153
  • [5] On-line sample clean-up for the LC/MS analysis of small molecules in serum
    Blythe, C. E.
    Pereira, L.
    Aspey, S.
    Milton, D.
    [J]. LC GC NORTH AMERICA, 2008, : 54 - 54
  • [6] On-line sample clean-up for LC-MS analysis of small molecules in serum
    Blythe, C. E.
    Pereira, L.
    Aspey, S.
    Milton, D.
    [J]. LC GC EUROPE, 2008, : 30 - 30
  • [7] Sensitive, high throughput HPLC-MS/MS method with on-line sample clean-up for everolimus measurement
    Korecka, Magdalena
    Solari, Sandra G.
    Shaw, Leslie M.
    [J]. THERAPEUTIC DRUG MONITORING, 2006, 28 (04) : 484 - 490
  • [8] Amberlite XAD-2 resin microcolumn coupled on-line to a flow injection approach for the preconcentration, clean-up and determination of trace phenols in waters
    Song, WL
    Wang, LS
    Zhi, ZL
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (10): : 1621 - 1623
  • [9] Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
    Van Eeckhout, N
    Perez, JC
    Van Peteghem, C
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (24) : 2331 - 2338
  • [10] Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
    Van Eeckhout, Nico
    Perez, José Castro
    Van Peteghem, Carlos
    [J]. 2000, John Wiley and Sons Ltd (14)