Real-time scanner error correction in white light interferometry

被引:10
|
作者
Chen, Dong [1 ]
Schmit, Joanna [1 ]
Novak, Matt [1 ]
机构
[1] Bruker Nano Surfaces, Tucson, AZ 85706 USA
关键词
white light interferometry; 3D microscopy; surface topography measurement; 3D metrology; automatic correction of scanner errors; ALGORITHMS;
D O I
10.1117/12.2071276
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
3D microscopes based on white light interferometry (WLI) with vertical scanning have been widely used in many areas of surface measurements and characterizations for decades. This technology provides fast, non-contact, and full-field surface 3D measurements with vertical resolution as low as the sub-nanometer range. Its applications include measurements of step height, surface roughness, film thickness, narrow trench and via depths as well as other geometric and texture parameters. In order to assure the highest accuracy of the measurement, scanner linearity needs to be maintained or monitored so that the nonlinearity can be accounted for during the measurement. This paper describes a method that accounts for nonlinearities in real time without the need to store frame data; in addition this method is shown to be less sensitive to vibrations than previous methods described. The method uses an additional interferometer, a distance measuring interferometer to measure the actual scanner position at each scan step.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] High-precision shape measurement by white-light interferometry with real-time scanner error correction
    Schmit, J
    Olszak, A
    [J]. APPLIED OPTICS, 2002, 41 (28) : 5943 - 5950
  • [2] High-stability white-light interferometry with reference signal for real-time correction of scanning errors
    Olszak, A
    Schmit, J
    [J]. OPTICAL ENGINEERING, 2003, 42 (01) : 54 - 59
  • [3] Multi-channelled white-light interferometry for real-time dispersion measurements
    Calatroni, J
    Sáinz, C
    Guerrero, AL
    [J]. OPTICS COMMUNICATIONS, 1998, 157 (1-6) : 202 - 208
  • [4] Fieldbus architecture with real-time error correction
    Erdner, T
    [J]. FIELDBUS TECHNOLOGY: SYSTEMS INTEGRATION, NETWORKING, AND ENGINEERING, 1999, : 387 - 393
  • [5] REAL-TIME INTERFEROMETRY
    SCHWIDER, J
    ELSSNER, KE
    SPOLACZYK, R
    MERKEL, K
    [J]. OPTICA APPLICATA, 1985, 15 (03) : 255 - 285
  • [6] Continuous real-time correction and averaging for frequency comb interferometry
    Roy, Julien
    Deschenes, Jean-Daniel
    Potvin, Simon
    Genest, Jerome
    [J]. OPTICS EXPRESS, 2012, 20 (20): : 21932 - 21939
  • [7] Error Correction for Foot Clearance in Real-Time Measurement
    Wahab, Y.
    Bakar, N. A.
    Mazalan, M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON SCIENCE & ENGINEERING IN MATHEMATICS, CHEMISTRY AND PHYSICS (SCIETECH 2014), 2014, 495
  • [8] Adaptive Forward Error Correction for Real-Time Groupware
    Dyck, Jeff
    Gutwin, Carl
    Makaroff, Dwight
    [J]. PROCEEDINGS OF THE 17TH ACM INTERNATIONAL CONFERENCE ON SUPPORTING GROUP WORK, 2012, : 121 - 130
  • [9] Real-time dispersion curves measurement from spectrally-resolved white-light interferometry
    Calatroni, JE
    Sainz, C
    Guerrero, AL
    [J]. OPTICAL INSPECTION AND MICROMEASUREMENTS II, 1997, 3098 : 308 - 315
  • [10] A MULTIMODE REAL-TIME SCANNER
    CARPENTER, DA
    DADD, MJ
    KOSSOFF, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (03): : 279 - 284