High-precision shape measurement by white-light interferometry with real-time scanner error correction

被引:60
|
作者
Schmit, J [1 ]
Olszak, A [1 ]
机构
[1] Veeco Instruments Inc, Tucson, AZ 85706 USA
关键词
D O I
10.1364/AO.41.005943
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
White-light interferometric techniques allow high-precision shape measurement of objects with discontinuous structures by detecting the peak of the coherence envelope. These techniques assume a specific change in the optical path difference (OPD) between the interfering beams; however, the scanning device effecting that change often introduces OPD errors that are carried over to the measurements. We present a technique for measuring OPD changes from the collected interference fringes during each measurement. Information about the scan is directly fed into the algorithm, which compensates for the errors, resulting in improved measurement accuracy. The method corrects not only the scanner errors but also slowly varying vibrations. In addition, this technique can be easily adapted to any existing low-coherence interferometer because no large data storage or postprocessing is required. (C) 2002 Optical Society of America.
引用
收藏
页码:5943 / 5950
页数:8
相关论文
共 50 条
  • [1] Real-time scanner error correction in white light interferometry
    Chen, Dong
    Schmit, Joanna
    Novak, Matt
    [J]. OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS III, 2014, 9276
  • [2] High-Precision Dynamic White-Light Interferometry
    Bi Shuxian
    Duan Mingliang
    Zong Yi
    Yu Caiyun
    Li Jianxin
    [J]. ACTA OPTICA SINICA, 2022, 42 (05)
  • [3] High-precision index measurement in anisotropic crystals using white-light spectral interferometry
    Delbarre, H
    Przygodzki, C
    Tassou, M
    Boucher, D
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2000, 70 (01): : 45 - 51
  • [4] High-precision index measurement in anisotropic crystals using white-light spectral interferometry
    H. Delbarre
    C. Przygodzki
    M. Tassou
    D. Boucher
    [J]. Applied Physics B, 2000, 70 : 45 - 51
  • [5] High-stability white-light interferometry with reference signal for real-time correction of scanning errors
    Olszak, A
    Schmit, J
    [J]. OPTICAL ENGINEERING, 2003, 42 (01) : 54 - 59
  • [6] High-precision broadband measurement of refractive index by picosecond real-time interferometry
    Tan, Zheng Jie
    Jin, Dafei
    Fang, Nicholas X.
    [J]. APPLIED OPTICS, 2016, 55 (24) : 6625 - 6629
  • [7] Real-time dispersion curves measurement from spectrally-resolved white-light interferometry
    Calatroni, JE
    Sainz, C
    Guerrero, AL
    [J]. OPTICAL INSPECTION AND MICROMEASUREMENTS II, 1997, 3098 : 308 - 315
  • [8] White-light interferometry with high measurement speed
    Pavlicek, Pavel
    Svak, Vojtech
    [J]. 19TH POLISH-SLOVAK-CZECH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2014, 9441
  • [9] White-light interferometry in high precision industrial applications
    Gross, R
    Ettl, P
    Laboureux, X
    Richter, C
    [J]. MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 123 - 130
  • [10] White-Light Interferometer Based on a High-Precision Chromatic Dispersion Measurement Method
    Kim, Seung Hwan
    Kim, Kyong Hon
    Lee, Seoung Hun
    Lee, Sukmock
    Lee, Min Hee
    Lee, El-Hang
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (06) : 3201 - 3206