Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing

被引:90
|
作者
Hwang, Hyun-Ji [1 ]
Lee, Sang J. [2 ]
Park, Eun-Jin [1 ]
Yoon, Hyung-In [1 ,3 ]
机构
[1] Ewha Womans Univ, Dept Prosthodont, Sch Med, 101 Daehak Ro, Seoul 03080, South Korea
[2] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA USA
[3] Seoul Natl Univ, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 01期
关键词
CAD/CAM TECHNOLOGY; CHALLENGES; ACCURACY; OPTIONS;
D O I
10.1016/j.prosdent.2018.02.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Limited information is available evaluating the trueness and tissue surface adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) maxillary denture bases fabricated using digital light processing (DLP). Purpose. The purpose of this in vitro study was to evaluate the trueness of DLP-fabricated denture bases and to compare the tissue surface adaptation of DLP with milling (MIL) and pack and press (PAP). Material and methods. The maxillary denture bases were virtually designed on the reference cast and were fabricated using DLP and MIL. Their intaglio surfaces were scanned and superimposed on the reference computer-aided design denture base to evaluate the trueness. A total of 20 denture bases (10 per technique) were also fabricated on the duplicated master casts using DLP and MIL. Ten denture bases were additionally made using PAP. The intaglio surfaces of the dentures were scanned and superimposed on the corresponding casts to compare the degree of tissue surface adaptation among the 3 techniques. The Mann-Whitney test and Kruskal-Wallis ANOVA were used for statistical analyses (alpha=.05). Results. The trueness of the DLP denture base was significantly better than that of the MIL denture base (P<.001). Statistically significant differences were detected with respect to tissue surface adaptation of the denture base among the groups (P<.001). The DLP denture base showed the best denture base fit among the 3 techniques with a small interquartile range. Conclusions. Within the limitations of this in vitro study, the DLP maxillary denture base showed better trueness and tissue surface adaptation of <= 100 mu m of the 3-dimensional surface deviation than the MIL and PAP denture bases.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 19 条
  • [1] Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing
    Yoon, Hyung-In
    Hwang, Hyun-Ji
    Ohkubo, Chikahiro
    Han, Jung-Suk
    Park, Eun-Jin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 919 - 926
  • [2] Tissue surface adaptation of CAD-CAM maxillary and mandibular complete denture bases manufactured by digital light processing: A clinical study
    Yoon, Se-Na
    Oh, Kyung Chul
    Lee, Sang J.
    Han, Jung-Suk
    Yoon, Hyung-In
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 682 - 689
  • [3] The effect of build angle on the tissue surface adaptation of maxillary and mandibular complete denture bases manufactured by digital light processing
    Jin, Mei-Cen
    Yoon, Hyung-In
    Yeo, In-Sung
    Kim, Sung-Hun
    Han, Jung-Suk
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (03): : 473 - 482
  • [4] Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: An in vitro study
    You, Seung-Min
    You, Seung-Gyu
    Lee, Beom-Il
    Kim, Ji-Hwan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 108 - 114
  • [5] Surface trueness and precision of interim restorations fabricated by digital light processing and CAD-CAM milling systems
    Thomas, Achsah Ann
    Daniel, Angleena Y.
    Gandhi, Nitasha
    Roy, Neethu
    Varghese, Kevin George
    Wadhwa, Samiksha
    Mathew, Jemin Elizabeth
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04): : 611.e1 - 611.e7
  • [6] Trueness assessment of additively manufactured maxillary complete denture bases produced at different orientations
    Cameron, Andrew B.
    Evans, Jane L.
    Abuzar, Menaka A.
    Tadakamadla, Santosh Kumar
    Love, Robert M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 129 - 135
  • [7] Effect of adhesives and mechanical surface treatments on the hard relining of CAD-CAM denture bases
    Karaokutan, Isil
    Ayvaz, Ilayda
    Ozel, Gulsum Sayin
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [8] Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies
    Ciocca, Leonardo
    Maltauro, Mattia
    Cimini, Valerio
    Breschi, Lorenzo
    Montanari, Angela
    Anderlucci, Laura
    Meneghello, Roberto
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (01): : 22 - 32
  • [9] Trueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materials
    Cakmak, Guelce
    Rusa, Ana Maria
    Donmez, Mustafa Borga
    Akay, Canan
    Kahveci, Cigdem
    Schimmel, Martin
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (05): : 951 - 958
  • [10] Impact of type of bonding agent on adhesion of CAD-CAM denture bases and teeth manufactured using different techniques: A preliminary study
    Denis, Corentin
    Abed, Adam
    Chai, Feng
    Vandomme, Jerome
    Dehurtevent, Marion
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2022, 35 (05): : 251 - 254