Surface trueness and precision of interim restorations fabricated by digital light processing and CAD-CAM milling systems

被引:4
|
作者
Thomas, Achsah Ann [1 ,2 ]
Daniel, Angleena Y. [1 ]
Gandhi, Nitasha [1 ]
Roy, Neethu [1 ]
Varghese, Kevin George [1 ]
Wadhwa, Samiksha [1 ]
Mathew, Jemin Elizabeth [1 ]
机构
[1] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana, Punjab, India
[2] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana 141008, Punjab, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 04期
关键词
PROVISIONAL CROWNS; ACCURACY; FIT;
D O I
10.1016/j.prosdent.2023.07.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The development of digital dental technologies has enabled clinicians to use additive and subtractive manufacturing techniques to fabricate interim restorations. However, knowledge of the trueness and precision of such restorations fabricated using digital light processing (DLP) and computer-aided design and computer-aided manufacturing (CAD-CAM) methods is limited.Purpose. The purpose of this in vitro study was to assess and compare the accuracy of interim crowns fabricated using DLP and CAD-CAM methods.Material and methods. A typodont mandibular first molar was prepared for a ceramic crown, and a digital scan (Medit T500) was obtained to design interim crowns by using the CAD software program. The CAD data were designated as the reference data. A total of 20 crowns were fabricated by DLP and CAD-CAM technology. The fabricated interim crowns were further scanned using a laboratory scanner and were superimposed with the CAD data by using a 3-dimensional (3D) point cloud assessing software program (CloudCompare) for the evaluation of trueness and precision. Root mean square values (RMS) were obtained for the evaluation of discrepancies. The Student t test was used to compare data as the Shapiro-Wilk test confirmed the normal distribution.Results. RMS values for the trueness values of the external and intaglio surfaces of the 3D printed and milled interim crown displayed no statistically significant differences (P>.05). Precision for the external surface reported significance (P<.05), whereas that for the intaglio surface reported no significance (P>.05).Conclusions. The accuracy of interim crowns fabricated by using DLP was comparable with that of milled crowns. Both manufacturing systems produced a true reproduction of the CAD. As for precision, the external surface of the DLP interim crown was statistically different from that of the milled group as it relates to the CAD.
引用
收藏
页码:611.e1 / 611.e7
页数:7
相关论文
共 50 条
  • [1] Effect of CAD-CAM tool deterioration on the trueness of ceramic restorations
    Al Hamad, Khaled Q.
    Al Rashdan, Rama B.
    Al Rashdan, Bashar A.
    Al Quran, Firas A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 635 - 644
  • [2] Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing
    Hwang, Hyun-Ji
    Lee, Sang J.
    Park, Eun-Jin
    Yoon, Hyung-In
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 110 - 117
  • [3] Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing
    Yoon, Hyung-In
    Hwang, Hyun-Ji
    Ohkubo, Chikahiro
    Han, Jung-Suk
    Park, Eun-Jin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 919 - 926
  • [4] Optical Impression Systems for CAD-CAM Restorations
    Prado Galhano, Graziela Avila
    Pellizzer, Eduardo Piza
    Quinelli Mazaro, Jose Vitor
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (06) : E575 - E579
  • [5] Effect of milling procedures in CAD-CAM systems on the color changes of CAD-CAM polymethyl methacrylate resin material as interim material
    Oyar, Perihan
    Ulusoy, Mutahhar
    [J]. BMC ORAL HEALTH, 2024, 24 (01):
  • [6] Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
    Bae, Eun-Bin
    Cho, Won-Tak
    Park, Do-Hyun
    Hwang, Su-Hyun
    Lee, So-Hyoun
    Yun, Mi-Jung
    Jeong, Chang-Mo
    Huh, Jung-Bo
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (03): : 155 - 170
  • [7] Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually
    Rayyan, Mohammad M.
    Aboushelib, Moustafa
    Sayed, Nagwa M.
    Ibrahim, Ahmed
    Jimbo, Ryo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (03): : 414 - 419
  • [8] Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: An in vitro study
    You, Seung-Min
    You, Seung-Gyu
    Lee, Beom-Il
    Kim, Ji-Hwan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 108 - 114
  • [9] In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems
    Hamza, Tamer A.
    Sherif, Rana M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06): : 762 - 766
  • [10] Influence of thermomechanical aging on marginal gap of CAD-CAM and conventional interim restorations
    Angwarawong, Thidarat
    Reeponmaha, Tanapon
    Angwaravong, Onauma
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 566.e1 - 566.e6