Statement of problem. Dental laboratories use different computer-aided design and computer aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. Purpose. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Material and methods. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of x100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (alpha=.05). Results. The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (+/- SD) highest marginal discrepancy was recorded in group TZI at 39.3 +/- 2.3 mu m, while the least mean marginal discrepancy was recorded in group IZ (22.8 +/- 8.9 mu m). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (P<.05). Conclusions. Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit.
引用
收藏
页码:762 / 766
页数:5
相关论文
共 50 条
  • [1] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    [J]. PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [2] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Avi Meirowitz
    Yoli Bitterman
    Sharon Levy
    Eitan Mijiritsky
    Eran Dolev
    [J]. BMC Oral Health, 19
  • [3] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Meirowitz, Avi
    Bitterman, Yoli
    Levy, Sharon
    Mijiritsky, Eitan
    Dolev, Eran
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [4] Marginal discrepancy and fracture load of thermomechanically fatigued crowns fabricated with different CAD-CAM techniques
    Sasany, Rafat
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 602 - 607
  • [5] An in vitro study measuring marginal gaps of inlay restorations fabricated from different CAD-CAM materials after thermocycling
    Taha, Ahmed Ismail
    Hafez, Mona Elshirbini
    [J]. BMC ORAL HEALTH, 2023, 23 (01)
  • [6] An in vitro study measuring marginal gaps of inlay restorations fabricated from different CAD-CAM materials after thermocycling
    Ahmed Ismail Taha
    Mona Elshirbini Hafez
    [J]. BMC Oral Health, 23
  • [7] Marginal fit of CAD-CAM monolithic zirconia crowns fabricated by using cone beam computed tomography scans
    Kale, Ediz
    Cilli, Mesutcan
    Ozcelik, Tuncer Burak
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (05): : 731 - 737
  • [8] Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study
    El Ghoul, Wiam A.
    Ozcan, Mutlu
    Ounsi, Hani
    Tohme, Hani
    Salameh, Ziad
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 128 - 134
  • [9] Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns
    Kale, Ediz
    Yilmaz, Burak
    Seker, Emre
    Ozcelik, Tuncer Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 736 - 741
  • [10] Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations
    Padros, Roberto
    Giner, Luis
    Herrero-Climent, Mariano
    Falcao-Costa, Carlos
    Rios-Santos, Jose-Vicente
    Gil, Francisco Javier
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 15