Marginal fit of CAD-CAM monolithic zirconia crowns fabricated by using cone beam computed tomography scans

被引:8
|
作者
Kale, Ediz [1 ]
Cilli, Mesutcan [1 ]
Ozcelik, Tuncer Burak [2 ]
Yilmaz, Burak [3 ]
机构
[1] Mustafa Kemal Univ, Dept Prosthodont, Fac Dent, Antakya, Turkey
[2] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 123卷 / 05期
关键词
ALL-CERAMIC CROWNS; FRACTURE-RESISTANCE; FILM THICKNESS; MOLAR CROWNS; ACCURACY; RESTORATIONS; REHABILITATION; DISCREPANCIES; IMPRESSIONS; CEMENTATION;
D O I
10.1016/j.prosdent.2019.05.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem: Information regarding the precision of monolithic zirconia crowns fabricated by using a standard computer-aided design and computer-aided manufacturing (CAD-CAM) workflow is available. However, information on the effect of a modified workflow using 3D laboratory scanning and/or cone beam computed tomography (CBCT) for monolithic zirconia crown fabrication is lacking. Purpose: The purpose of this in vitro study was to evaluate the effect of different scans on the marginal fit of CAD-CAM monolithic zirconia crowns fabricated by 3D laboratory scanning and CBCT. Material and methods: An extracted maxillary left first molar was prepared and digitized by using a 3D laboratory scanner (D900; 3Shape A/S) (control group). The tooth was also scanned by CBCT (i-CAT; Imaging Sciences) to generate a second virtual 3D model (CBCTscan group). A tooth cast out of polyurethane (PU) (Zenotec Model; Wieland) was reproduced from the CBCT data by using a CAD software program (Dental System 2.6; 3Shape A/S) and milling machine (CORiTEC 550i; imes-icore) and further scanned by using the 3D laboratory scanner to generate a third virtual 3D model to represent a clinical scenario where a patient's cast is needed (PU3DLab group). A monolithic zirconia crown design (cement space: margin 40 mu m, 1 mm above 70 mu m) was used on the virtual models, and crowns were fabricated out of presintered zirconia blocks (ZenostarT4; Wieland) by using a 5-axis milling machine (CORiTEC 550i; imes-icore). The crowns were sintered (Sinterofen HT-S Speed; Mihm-Vogt), and the vertical marginal discrepancy (VMD) was measured by x100-magnification microscopy. Measurements were made at 384 points in 3 groups of 16 specimens. The measurements for each specimen were averaged, and VMD mean values were calculated. The Kruskal-Wallis test was used for the statistical analysis (alpha=.05). The Mann-Whitney U test and Bonferroni adjustment were further used to compare the pairs (alpha=.017). Results: The mean VMD value was 41 mu m (median: 38 mu m) for the control group, 44 mu m (median: 42 mu m) for the CBCTscan, and 60 mu m (median: 58 mu m) for the PU3DLab. No significant difference was found between control and CBCTscan groups (P=.274). However, there was a significant difference between control and PU3DLab and CBCTscan and PU3DLab groups (P<.001). Conclusions: Marginal fit of the crowns fabricated by using the 3D laboratory scanner and through the direct use of CBCT was better than that of the crowns fabricated by using the workflow that combined the use of CBCT, PU cast, and 3D laboratory scanner. All tested protocols enabled the fabrication of monolithic zirconia crowns with a marginal discrepancy smaller than 120 mu m.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [1] Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study
    Belgin, Huseyin Berkay
    Kale, Ediz
    Ozcelik, Tuncer Burak
    Yilmaz, Burak
    [J]. ODONTOLOGY, 2022, 110 (02) : 339 - 348
  • [2] Marginal fit of 3-unit CAD–CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study
    Hüseyin Berkay Belgin
    Ediz Kale
    Tuncer Burak Özçelik
    Burak Yilmaz
    [J]. Odontology, 2022, 110 : 339 - 348
  • [3] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    [J]. PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [4] Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns
    Kale, Ediz
    Yilmaz, Burak
    Seker, Emre
    Ozcelik, Tuncer Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 736 - 741
  • [5] Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns
    Kale, Ediz
    Seker, Emre
    Yilmaz, Burak
    Ozcelik, Tuncer Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (06): : 890 - 895
  • [6] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Avi Meirowitz
    Yoli Bitterman
    Sharon Levy
    Eitan Mijiritsky
    Eran Dolev
    [J]. BMC Oral Health, 19
  • [7] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Meirowitz, Avi
    Bitterman, Yoli
    Levy, Sharon
    Mijiritsky, Eitan
    Dolev, Eran
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [8] Effect of cementation and aging on the marginal fit of veneered and monolithic zirconia and metal-ceramic CAD-CAM crowns
    Del Pinal, Maria
    Lopez-Suarez, Carlos
    Bartolome, Jose F.
    Volpato, Claudia AM.
    Suarez, Maria J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 323.e1 - 323.e7
  • [9] Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns
    Lee, Seulgi
    Choi, Gyujin
    Choi, Jinhyeok
    Kim, Youngjun
    Kim, Hee-Kyung
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [10] Effect of high-speed sintering on the marginal and internal fit of CAD/CAM-fabricated monolithic zirconia crowns
    Seulgi Lee
    Gyujin Choi
    Jinhyeok Choi
    Youngjun Kim
    Hee-Kyung Kim
    [J]. Scientific Reports, 13 (1)