Impact of type of bonding agent on adhesion of CAD-CAM denture bases and teeth manufactured using different techniques: A preliminary study

被引:0
|
作者
Denis, Corentin [1 ,2 ]
Abed, Adam [4 ]
Chai, Feng [2 ]
Vandomme, Jerome [3 ]
Dehurtevent, Marion [1 ,2 ]
机构
[1] Univ Lille, Fac Dent Surg, Dept Prosthodont, Lille, France
[2] Univ Lille, CHU Lille, INSERM U1008, Controlled Drug Delivery Syst & Biomat, Lille, France
[3] Univ Lille, Dept Prosthodont, Lille, France
[4] Univ Lille, Fac Dent Surg, Lille, France
来源
AMERICAN JOURNAL OF DENTISTRY | 2022年 / 35卷 / 05期
关键词
STRENGTH;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate two agents for bonding denture bases and teeth manufactured either by stereolithography (SLA) or by the subtractive mixed technique. Methods: Two types of cylinders [small for the tooth resin and large for the base resin) were designed using CAD software according to the ANSI/ADA 15-2008 (R2013)] specification. For SLA manufacturing, 30 small cylinders were shaped with Denture Teeth resin and 30 large cylinders with Denture Base resin. For the mixed technique, 30 large cylinders were manufactured by SLA with V-print dentbase resin, and 30 small cylinders were milled with a CediTEC DT disk. Half the specimens were bonded with liquid Denture Base resin and half with CediTEC Primer and Adhesive, according to the manufacturers' protocols. Shear bond strength was measured using a universal testing machine. The failure mode was noted for all the specimens. Results: The shear bond strength values were not significantly different between the groups (P> 0.05). Specimens bonded with liquid Denture Base resin displayed cohesive failure (P> 0.05, chi(2)= 0). Of the specimens bonded with CediTEC Primer and Adhesive, cohesive failures were observed with five specimens manufactured with the SLA technique and one specimen manufactured with the mixed technique (P> 0.05, chi(2)= 3.33). The Chi-square test results were significant between groups with different bonding agents regardless of the technique used (P< 0.001). Within the limitations of the present study, even if the shear bond strength values were similar, the failure mode analysis suggests that the uncured liquid Denture Base resin may be more effective than the CediTEC Primer and Adhesive for bonding denture bases and teeth manufactured either by SLA or the mixed technique.
引用
收藏
页码:251 / 254
页数:4
相关论文
共 22 条
  • [1] A method to improve positioning of denture teeth on denture bases for CAD-CAM complete dentures: A dental technique
    Feng, Yue
    Ma, Sai
    Zhong, Sheng
    Niu, Lina
    Feng, Zhihong
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 46 - 50
  • [2] Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing
    Hwang, Hyun-Ji
    Lee, Sang J.
    Park, Eun-Jin
    Yoon, Hyung-In
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 110 - 117
  • [3] Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing
    Yoon, Hyung-In
    Hwang, Hyun-Ji
    Ohkubo, Chikahiro
    Han, Jung-Suk
    Park, Eun-Jin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 919 - 926
  • [4] Tissue surface adaptation of CAD-CAM maxillary and mandibular complete denture bases manufactured by digital light processing: A clinical study
    Yoon, Se-Na
    Oh, Kyung Chul
    Lee, Sang J.
    Han, Jung-Suk
    Yoon, Hyung-In
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 682 - 689
  • [5] Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
    You, Seung-Gyu
    You, Seung-Min
    Kang, Seen-Young
    Bae, So-Yeon
    Kim, Ji-Hwan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 479 - 485
  • [6] Impact of CAD/CAM Material and Bonding Protocol on the Bond Strength Between Denture Bases and Artificial Teeth: A Systematic Review and Meta- analysis
    Carneiro Pereira, Ana Larisse
    Madrid Troconis, Cristhian Camilo
    Melo Segundo, Henrique Vieira
    Barao, Valentim A. R.
    Porto Carreiro, Adriana da Fonte
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (06) : 769 - +
  • [7] Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study
    Helal, Mohamed Ahmed
    Abdelrahim, Ramy Abdallah
    Zeidan, Ahmed Abd El-latif
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 11 - 19
  • [8] Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: An in vitro study
    You, Seung-Min
    You, Seung-Gyu
    Lee, Beom-Il
    Kim, Ji-Hwan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 108 - 114
  • [9] Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study
    Neena, Akram F.
    Abd-Ellah, Mervat E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 705e1 - 705e7
  • [10] Fit and retention of complete denture bases: Part I e Conventional versus CAD-CAM methods: A clinical controlled crossover study
    Maniewicz, Sabrina
    Imamura, Yoshiki
    El Osta, Nada
    Srinivasan, Murali
    Muller, Frauke
    Chebib, Najla