Optical and electrical detection of single pulse of partial discharge on electrical treeing

被引:0
|
作者
Ehara, Y [1 ]
Tsuno, M [1 ]
Kishida, H [1 ]
Ito, T [1 ]
机构
[1] Musashi Inst Technol, Dept Elect & Electro Eng, Setagaya Ku, Tokyo 1588557, Japan
关键词
D O I
10.1109/ISEIM.1998.741824
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this study is to analyze the treeing degradation process by measuring partial discharge pulse and discharge luminous image of single pulse. In the measurement system, PMMA blocks were used with electrodes consisting of a needle and a plate. One cycle of an applied ac voltage was divided into twenty equal phase angle sections, labeled phi(1), phi(2), ... ,phi(20) in order, from one negative peak to the next negative peak of the applied voltage. A high voltage was applied to the needle electrode, positive discharge pulses and discharge luminescences were measured at the same time between phi(3) and phi(9). As a result, the discharge luminescence at phi(3) and phi(4) occurred mainly in the void area independently of the discharge magnitude. At phi(7,) phi(8) and phi(9), the discharge luminescence was observed in the void area when the discharge magnitude was small, in the tree area when it was comparatively large. The discharge luminescence reached near the tip of tree channel.
引用
收藏
页码:639 / 642
页数:4
相关论文
共 50 条
  • [1] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    [J]. 2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1709 - +
  • [2] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    [J]. ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1665 - 1670
  • [3] An Investigation of the Harmonic Impact on Electrical Treeing Partial Discharge Activity
    Bahadoorsingh, S.
    Rowland, S. M.
    [J]. CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [4] Analysis of Partial Discharge Features as Prognostic Indicators of Electrical Treeing
    Aziz, N. H.
    Catterson, V. M.
    Rowland, S. M.
    Bahadoorsingh, S.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 129 - 136
  • [5] STUDIES ON ELECTRICAL TREEING AND PARTIAL DISCHARGE PROPERTIES OF PE/MMT NANOCOMPOSITES
    Zhang Xiaohong
    Liu Jiayin
    Zhang Jinmei
    Ji Quanquan
    Gao Junguo
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 96 - 96
  • [6] Pulse-sequence analysis of partial discharges in a void and electrical treeing
    Suwarno
    Suzuoki, Y
    Mizutani, T
    [J]. CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 130 - 133
  • [7] Optical pulse method for partial discharge measurement and the comparison with electrical current method
    Xu, Y.
    Yu, M.
    Cao, X.L.
    Qiu, C.R.
    Zhen, W.H.
    Hu, S.J.
    [J]. Gaodianya Jishu/High Voltage Engineering, 2001, 27 (04):
  • [8] Characteristics of Partial Discharge During Electrical Treeing in XLPE Under DC Voltage
    Zhu, Xi
    Lin, Guohai
    Zhang, Hongliang
    Wang, Yalin
    Wu, Jiandong
    Yin, Yi
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (06): : 2416 - 2426
  • [9] ELECTRICAL AND OPTICAL MEASUREMENTS IN A PULSE HELIUM DISCHARGE
    VAGNER, SD
    SLYSHOV, AG
    KAGAN, YM
    [J]. OPTIKA I SPEKTROSKOPIYA, 1972, 32 (04): : 650 - &
  • [10] ANALYSIS OF THE PROPAGATION OF ELECTRICAL TREEING USING OPTICAL AND ELECTRICAL METHODS
    LAURENT, C
    MAYOUX, C
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1980, 15 (01): : 33 - 42