Partial discharge phenomena due to electrical treeing in XLPE

被引:0
|
作者
Yang, J. J. [1 ]
Zhang, D. M. [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Increased electrical stress due to cable joints was simulated by point-plane electrode configuration. Electrical tree formed in XLPE insulation sliced from 220kV rated cable was diagnosed by partial discharge and dielectrometry measurements and optical observation. With increasing voltage at the rate of 1kV/10min, various analyses for PD pulses distribution in 20 ms and single pulses were carried out to compare the effects of applied voltage. Two types of electrical trees have been found out based on PD analysis and optical recording. Observed light emission supported the theory of emission by protons due to high-energy electrons. The analysis was supported with dielectrometry measurements on the sample before and after tree formation. And also, typical models were developed to study the mechanism of treeing.
引用
收藏
页码:1709 / +
页数:2
相关论文
共 50 条
  • [1] Partial discharge phenomena due to electrical treeing in XLPE
    Yang, J. J.
    Zhang, D. M.
    [J]. ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1665 - 1670
  • [2] Characteristics of Partial Discharge During Electrical Treeing in XLPE Under DC Voltage
    Zhu, Xi
    Lin, Guohai
    Zhang, Hongliang
    Wang, Yalin
    Wu, Jiandong
    Yin, Yi
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (06): : 2416 - 2426
  • [3] Effect of Aromatic Compounds Content on Electrical Treeing and Partial Discharge Characteristics of XLPE Insulation
    Lü, Lixiang
    Yang, Zhuoran
    Yao, Tianyi
    Gao, Yuan
    Wang, Heyu
    Li, Zhonglei
    [J]. Gaodianya Jishu/High Voltage Engineering, 2023, 49 (05): : 1949 - 1957
  • [4] Study on the Morphology and Propagation of Electrical Treeing by Partial Discharge Patterns in XLPE Power Cables
    Tang, Chao
    Li, Jiao
    Liao, Ruijin
    Zhou, Tianchun
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (03): : 4639 - 4646
  • [5] Study on the partial discharge characteristics of the XLPE insulation samples during electrical treeing ageing
    Cheng, YH
    Chen, XL
    Rong, MZ
    Yue, B
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 211 - 214
  • [6] Partial Discharge Characteristics of Electrical Treeing in XLPE insulation utilizing Multi Level PWM Waveforms
    Hammarstrom, Thomas John Ake
    [J]. 2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 4699 - 4704
  • [7] Partial discharge characteristics of electrical treeing in XLPE insulation exposed to voltages of different rise times
    Hammarström, Thomas
    Bengtsson, Tord
    Gubanski, Stanislaw M.
    [J]. IEEJ Transactions on Fundamentals and Materials, 2019, 139 (02) : 85 - 91
  • [8] Partial Discharge Characteristics of Electrical Treeing in XLPE Insulation Exposed to Voltages of Different Rise Times
    Hammarstrom, T. J. A.
    Bengtsson, T.
    Gubanski, S. M.
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 407 - 410
  • [9] Structural Effects on Treeing Phenomena in XLPE
    Nilsson, Susanne
    Hjertberg, Thomas
    Smedberg, Annika
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 166 - 166
  • [10] A comprehensive circuit model for partial discharge activities in cable insulation due to electrical treeing
    Pour, A. Najafi
    Shahrtash, S. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 44 (01) : 646 - 655