Room temperature semiconductor detectors for safeguards measurements

被引:26
|
作者
Arlt, R
Rundquist, DE
机构
[1] International Atomic Energy Agency, A-1400, Vienna
[2] International Atomic Energy Agency, Vienna
关键词
D O I
10.1016/S0168-9002(96)00475-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A summary is given of the principal areas of application where CdTe detectors are presently used by the IAEA in nuclear material safeguards. Hemispheric detectors with a sensitive volume of about 20 mm(3) have their principal application in the verification of irradiated nuclear material. Larger volume hemispheric detectors are used for the verification of unirradiated material. Their availability, however, is still limited. Problems with the commercial supply of detectors and with ruggedizing the design of the miniature detection probes need to be solved. New results which are relevant for future applications are described. it has been shown that hemispheric detectors made of CdZnTe provide a resolution of 3-4% and a peak/Compton ratio larger than two for Cs-137. Large volume planar CdZnTe have been used in conjunction with pulse shape discrimination electronics. The detector efficiency, however, still remains below the values expected from their geometric dimensions. A new technique to achieve single charge collection in large volume CdZnTe detectors has been developed. Planar detectors with PIN structure and Peltier cooling have further improved. However, the problem of long term stability has not been solved yet. Silicon detectors are increasingly used in unattended radiation monitoring systems. They have a proven long term stability and can cover a signal range of 5-6 decades if used with fast pulse counting electronics.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 50 条
  • [1] Survey of radiation damage measurements in room temperature semiconductor radiation detectors
    Brunett, BA
    Doyle, BL
    Franks, LA
    James, RB
    Olsen, RW
    Trombka, JI
    Vizkelthy, G
    Walsh, DS
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 433 - 441
  • [2] Radiation damage measurements in room-temperature semiconductor radiation detectors
    Franks, LA
    Brunett, BA
    Olsen, RW
    Walsh, DS
    Vizkelethy, G
    Trombka, JI
    Doyle, BL
    James, RB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 95 - 101
  • [3] Room temperature semiconductor detectors for nuclear security
    Johns, Paul M.
    Nino, Juan C.
    [J]. JOURNAL OF APPLIED PHYSICS, 2019, 126 (04)
  • [4] Continued Development of Room Temperature Semiconductor Nuclear Detectors
    Kim, Hadong
    Cirignano, Leonard
    Churilov, Alexei
    Ciampi, Guido
    Kargar, Alireza
    Higgins, William
    O'Dougherty, Patrick
    Kim, Suyoung
    Squillante, Michael R.
    Shah, Kanai
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS XI, 2010, 7806
  • [5] Room-temperature compound semiconductor radiation detectors
    McGregor, DS
    Hermon, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01): : 101 - 124
  • [6] Stable room-temperature thallium bromide semiconductor radiation detectors
    Datta, A.
    Fiala, J.
    Becla, P.
    Motakef, Shariar
    [J]. APL MATERIALS, 2017, 5 (10):
  • [7] Pulse shape discrimination system for room-temperature semiconductor detectors
    Kondrashov, V
    Loupilov, A
    Ivanov, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 580 - 584
  • [8] Room-temperature semiconductor detectors for in vivo monitoring of internal contamination
    Genicot, JL
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 : 1423 - 1426
  • [9] Latest developments in room-temperature semiconductor neutron detectors: Prospects and challenges
    Liu, Linyue
    Ouyang, Xiao
    Gao, Runlong
    Wan, Pengying
    Ouyang, Xiaoping
    [J]. SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2023, 66 (03)
  • [10] Semimetal-semiconductor rectifiers for sensitive room-temperature microwave detectors
    Young, AC
    Zimmerman, JD
    Brown, ER
    Gossard, AC
    [J]. APPLIED PHYSICS LETTERS, 2005, 87 (16) : 1 - 3