Pulse shape discrimination system for room-temperature semiconductor detectors

被引:6
|
作者
Kondrashov, V [1 ]
Loupilov, A [1 ]
Ivanov, V [1 ]
机构
[1] Balt Sci Instruments, LV-1005 Riga, Latvia
关键词
pulse shape correction and selection;
D O I
10.1016/S0168-9002(00)00919-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Easily adjustable pulse shape discrimination (PSD) system effectively operating in the wide range of registered energies is offered. Shape distortions of the detector output signal due to charge losses are clearly visible if one carries out shape analysis of the spectrometric signal for pulses restored up to the rectangular shape. The essence of the method consists in the analysis of difference of a restored signal form from rectangular. For this purpose the area of a pulse is measured within the given interval at once after incoming pulse and within the same time interval delayed concerning first. In case of an inequality of these areas, the signal is considered deformed and is not exposed to further analysis. Schematic decision and operation mode of PSD system is analysed, pulses diagrams are presented. The developed PSD system was applied in gamma-spectrometer with planar geometry CdTe detector with dimensions 5 x 5 x 3 mm(3). Detector had m-s-m structure with gold electrode. Initial energy resolution of the detector was 17keV at 662keV and peak-to-Compton ratio equal to 1.8. The PSD application improves energy resolution up to 3.2 keV and peak-to-Compton ratio to about 5.0. At this essential reduction of count rate (up to 75%) in a maximum of a total absorption peak is observed. But the energy resolution of about 6 keV can be received at insignificant (not more than 20%) reduction of count rate. Spectra of Cs-137 and Ba-133 obtained with and without PSD system application are shown. Diagrams of energy resolution at 662 keV line as well as count rate in the total absorption peak maximum versus pulse shape discrimination level are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [1] Room-temperature compound semiconductor radiation detectors
    McGregor, DS
    Hermon, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01): : 101 - 124
  • [2] Radiation damage measurements in room-temperature semiconductor radiation detectors
    Franks, LA
    Brunett, BA
    Olsen, RW
    Walsh, DS
    Vizkelethy, G
    Trombka, JI
    Doyle, BL
    James, RB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 95 - 101
  • [3] Stable room-temperature thallium bromide semiconductor radiation detectors
    Datta, A.
    Fiala, J.
    Becla, P.
    Motakef, Shariar
    [J]. APL MATERIALS, 2017, 5 (10):
  • [4] Room-temperature semiconductor detectors for in vivo monitoring of internal contamination
    Genicot, JL
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 : 1423 - 1426
  • [5] Latest developments in room-temperature semiconductor neutron detectors: Prospects and challenges
    Liu, Linyue
    Ouyang, Xiao
    Gao, Runlong
    Wan, Pengying
    Ouyang, Xiaoping
    [J]. SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2023, 66 (03)
  • [6] Charge transport properties in CdZnTeSe semiconductor room-temperature γ-ray detectors
    Chaudhuri, Sandeep K.
    Sajjad, Mohsin
    Kleppinger, Joshua W.
    Mandal, Krishna C.
    [J]. JOURNAL OF APPLIED PHYSICS, 2020, 127 (24)
  • [7] Semimetal-semiconductor rectifiers for sensitive room-temperature microwave detectors
    Young, AC
    Zimmerman, JD
    Brown, ER
    Gossard, AC
    [J]. APPLIED PHYSICS LETTERS, 2005, 87 (16) : 1 - 3
  • [8] Latest developments in room-temperature semiconductor neutron detectors: Prospects and challenges
    Linyue Liu
    Xiao Ouyang
    Runlong Gao
    Pengying Wan
    Xiaoping Ouyang
    [J]. Science China(Physics,Mechanics & Astronomy), 2023, (03) : 15 - 35
  • [9] Latest developments in room-temperature semiconductor neutron detectors: Prospects and challenges
    Linyue Liu
    Xiao Ouyang
    Runlong Gao
    Pengying Wan
    Xiaoping Ouyang
    [J]. Science China Physics, Mechanics & Astronomy, 2023, 66
  • [10] A new method for charge-loss correction of room-temperature semiconductor detectors using digital trapezoidal pulse shaping
    Nakhostin, M.
    Veeramani, P.