Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure

被引:0
|
作者
Zhang, Guanqun [1 ]
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
关键词
PRE-EJECTION PERIOD; BLOOD-PRESSURE; WAVE VELOCITY; MARKER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared pulse arrival time (PAT) and pulse transit time (PTT) in terms of their ability to track diastolic pressure (DP). We performed the comparison using high fidelity, invasive arterial waveforms recorded from six dogs during multiple interventions. On average, DP ranged from 40 to 106 mmHg and therefore varied widely. PAT and PTT were able to predict DP with average root-mean-squared-errors of 9.8 +/- 5.8 mmHg and 5.7 +/- 2.0 mmHg (p = 0.02). Thus, even though PAT is simpler to measure, we can only recommend using PTT for tracking DP.
引用
收藏
页码:6462 / 6464
页数:3
相关论文
共 50 条
  • [1] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686
  • [2] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure (vol 111, pg 1681, 2011)
    Zhang, G.
    Gao, M.
    Xu, D.
    Olivier, N. B.
    Mukkamala, R.
    JOURNAL OF APPLIED PHYSIOLOGY, 2014, 117 (10) : 112 - 112
  • [3] Difference in Pulse Arrival Time at Forehead and at Finger as a Surrogate of Pulse Transit Time
    Lazaro, Jesus
    Bailon, Raquel
    Laguna, Pablo
    Marozas, Vaidotas
    Rapalis, Andrius
    Gil, Eduardo
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 269 - 272
  • [4] Pulse arrival time as a surrogate of blood pressure
    Eoin Finnegan
    Shaun Davidson
    Mirae Harford
    João Jorge
    Peter Watkinson
    Duncan Young
    Lionel Tarassenko
    Mauricio Villarroel
    Scientific Reports, 11
  • [5] Pulse arrival time as a surrogate of blood pressure
    Finnegan, Eoin
    Davidson, Shaun
    Harford, Mirae
    Jorge, Joao
    Watkinson, Peter
    Young, Duncan
    Tarassenko, Lionel
    Villarroel, Mauricio
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] EXPERIENCES WITH PULSE ARRIVAL TIME AS SURROGATE FOR SYSTOLIC BLOOD PRESSURE
    Muehlsteff, J.
    Kelm, M.
    Meyer, C.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [7] Using the pulse transit time for calculation of systolic and diastolic pressure
    Corciova, C.
    Matei, D.
    Corciova, F.
    ACTA PHYSIOLOGICA, 2014, 211 : 87 - 87
  • [8] Estimation of systolic and diastolic pressure using the pulse transit time
    Ye, Soo-Young
    Kim, Gi-Ryon
    Jung, Dong-Keun
    Baik, Seong-Wan
    Jeon, Gye-Rok
    World Academy of Science, Engineering and Technology, 2010, 43 : 726 - 731
  • [9] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [10] Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time
    Stephanie L.-O. Martin
    Andrew M. Carek
    Chang-Sei Kim
    Hazar Ashouri
    Omer T. Inan
    Jin-Oh Hahn
    Ramakrishna Mukkamala
    Scientific Reports, 6