Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure

被引:0
|
作者
Zhang, Guanqun [1 ]
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
关键词
PRE-EJECTION PERIOD; BLOOD-PRESSURE; WAVE VELOCITY; MARKER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We compared pulse arrival time (PAT) and pulse transit time (PTT) in terms of their ability to track diastolic pressure (DP). We performed the comparison using high fidelity, invasive arterial waveforms recorded from six dogs during multiple interventions. On average, DP ranged from 40 to 106 mmHg and therefore varied widely. PAT and PTT were able to predict DP with average root-mean-squared-errors of 9.8 +/- 5.8 mmHg and 5.7 +/- 2.0 mmHg (p = 0.02). Thus, even though PAT is simpler to measure, we can only recommend using PTT for tracking DP.
引用
收藏
页码:6462 / 6464
页数:3
相关论文
共 50 条
  • [41] SPHYGMOCHRONOGRAM (PLOT OF CUFF PRESSURE AGAINST PULSE ARRIVAL TIME) AS AN INDEX OF VENTRICULAR-FUNCTION AND OF DIASTOLIC BLOOD-PRESSURE
    CARLISLE, R
    CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1977, 53 (03): : P8 - P8
  • [42] EVOLUTION OF TRANSIT TIME BETWEEN THE SYSTOLIC AND DIASTOLIC PRESSURE PEAKS OF THE RADIAL PULSE WAVEFORM AFTER KIDNEY TRANSPLANTATION
    Philibert, Emy
    Obeid, Hasan
    Pare, Mathilde
    Cote, Nadege
    Fortier, Catherine
    Goupil, Remi
    Agharazii, Mohsen
    JOURNAL OF HYPERTENSION, 2021, 39 : E306 - E306
  • [43] Pulse waveform as an indicator of baseline offset in pulse transit time based blood pressure estimation
    Lin, Chen
    Zhou, Yuan
    Wang, Hu
    Wang, Yao
    2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 26 - 31
  • [44] Aortic-Finger Pulse Transit Time vs. R-derived Pulse Arrival Time: a Beat-to-Beat Assessment
    Vaini, Emanuele
    Lombardi, Prospero
    Di Rienzo, Marco
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 253 - 256
  • [45] Determination of pulse transit time from waveform decomposition of the derived central aortic pressure pulse
    Qasem, A.
    Avolio, A.
    JOURNAL OF HYPERTENSION, 2006, 24 : S356 - S356
  • [46] Pulse Arrival Time and Ballistocardiogram Application to Blood Pressure Variability Estimation
    Pinheiro, Eduardo
    Postolache, Octavian
    Girao, Pedro
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 132 - +
  • [47] Monitoring of intrapleural pressure using peripheral pulse arrival time in human
    Jung, DK
    Huh, JT
    Bae, HR
    Suh, DJ
    FASEB JOURNAL, 2001, 15 (05): : A863 - A863
  • [48] Evaluation of blood pressure estimation models based on pulse arrival time
    Bote, Jose M.
    Recas, Joaquin
    Hermida, Roman
    COMPUTERS & ELECTRICAL ENGINEERING, 2020, 84
  • [49] ON-LINE PULSE ARRIVAL TIME CALCULATOR FOR MEASUREMENT OF INTRACRANIAL PULSE ARRIVAL TIMES
    BARNES, R
    MCKINNEY, WM
    TOOLE, JF
    NUSS, PH
    LAMB, PG
    NEUROLOGY, 1971, 21 (04) : 427 - &
  • [50] Blood pressure altering method affects correlation with pulse arrival time
    Heimark, Sondre
    Rindal, Ole Marius H.
    Seeberg, Trine M.
    Stepanov, Alexey
    Boysen, Elin S.
    Botker-Rasmussen, Kasper G.
    Mobaek, Nina K.
    Soraas, Camilla L.
    Stenehjem, Aud E.
    Elmula, Fadl Elmula M. Fadl
    Waldum-Grevbo, Bard
    BLOOD PRESSURE MONITORING, 2022, 27 (02) : 139 - 146