Pulse arrival time as a surrogate of blood pressure

被引:0
|
作者
Eoin Finnegan
Shaun Davidson
Mirae Harford
João Jorge
Peter Watkinson
Duncan Young
Lionel Tarassenko
Mauricio Villarroel
机构
[1] University of Oxford,Department of Engineering Science, Institute of Biomedical Engineering
[2] University of Oxford,Critical Care Research Group, Nuffield Department of Clinical Neurosciences
[3] NIHR Oxford Biomedical Research Centre,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Various models have been proposed for the estimation of blood pressure (BP) from pulse transit time (PTT). PTT is defined as the time delay of the pressure wave, produced by left ventricular contraction, measured between a proximal and a distal site along the arterial tree. Most researchers, when they measure the time difference between the peak of the R-wave in the electrocardiogram signal (corresponding to left ventricular depolarisation) and a fiducial point in the photoplethysmogram waveform (as measured by a pulse oximeter attached to the fingertip), describe this erroneously as the PTT. In fact, this is the pulse arrival time (PAT), which includes not only PTT, but also the time delay between the electrical depolarisation of the heart’s left ventricle and the opening of the aortic valve, known as pre-ejection period (PEP). PEP has been suggested to present a significant limitation to BP estimation using PAT. This work investigates the impact of PEP on PAT, leading to a discussion on the best models for BP estimation using PAT or PTT. We conducted a clinical study involving 30 healthy volunteers (53.3% female, 30.9 ± 9.35 years old, with a body mass index of 22.7 ± 3.2 kg/m2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$^{2}$$\end{document}). Each session lasted on average 27.9 ± 0.6 min and BP was varied by an infusion of phenylephrine (a medication that causes venous and arterial vasoconstriction). We introduced new processing steps for the analysis of PAT and PEP signals. Various population-based models (Poon, Gesche and Fung) and a posteriori models (inverse linear, inverse squared and logarithm) for estimation of BP from PTT or PAT were evaluated. Across the cohort, PEP was found to increase by 5.5 ms ± 4.5 ms from its baseline value. Variations in PTT were significantly larger in amplitude, − 16.8 ms ± 7.5 ms. We suggest, therefore, that for infusions of phenylephrine, the contribution of PEP on PAT can be neglected. All population-based models produced large BP estimation errors, suggesting that they are insufficient for modelling the complex pathways relating changes in PTT or PAT to changes in BP. Although PAT is inversely correlated with systolic blood pressure (SBP), the gradient of this relationship varies significantly from individual to individual, from − 2946 to − 470.64 mmHg/s in our dataset. For the a posteriori inverse squared model, the root mean squared errors (RMSE) for systolic and diastolic blood pressure (DBP) estimation from PAT were 5.49 mmHg and 3.82 mmHg, respectively. The RMSEs for SBP and DBP estimation by PTT were 4.51 mmHg and 3.53 mmHg, respectively. These models take into account individual calibration curves required for accurate blood pressure estimation. The best performing population-based model (Poon) reported error values around double that of the a posteriori inverse squared model, and so the use of population-based models is not justified.
引用
收藏
相关论文
共 50 条
  • [1] Pulse arrival time as a surrogate of blood pressure
    Finnegan, Eoin
    Davidson, Shaun
    Harford, Mirae
    Jorge, Joao
    Watkinson, Peter
    Young, Duncan
    Tarassenko, Lionel
    Villarroel, Mauricio
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] EXPERIENCES WITH PULSE ARRIVAL TIME AS SURROGATE FOR SYSTOLIC BLOOD PRESSURE
    Muehlsteff, J.
    Kelm, M.
    Meyer, C.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [3] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686
  • [4] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure (vol 111, pg 1681, 2011)
    Zhang, G.
    Gao, M.
    Xu, D.
    Olivier, N. B.
    Mukkamala, R.
    JOURNAL OF APPLIED PHYSIOLOGY, 2014, 117 (10) : 112 - 112
  • [5] Pulse Arrival Time is Not an Adequate Surrogate for Pulse Transit Time in Terms of Tracking Diastolic Pressure
    Zhang, Guanqun
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6462 - 6464
  • [6] Pulse Arrival Time as Surrogate for Systolic Blood Pressure Changes during Impending Neurally Mediated Syncope
    Muehlsteff, Jens
    Ritz, Anita
    Drexel, Thomas
    Eickholt, Christian
    Carvalho, Paulo
    Couceiro, Ricardo
    Kelm, Malte
    Meyer, Christian
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4283 - 4286
  • [7] Difference in Pulse Arrival Time at Forehead and at Finger as a Surrogate of Pulse Transit Time
    Lazaro, Jesus
    Bailon, Raquel
    Laguna, Pablo
    Marozas, Vaidotas
    Rapalis, Andrius
    Gil, Eduardo
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 269 - 272
  • [8] Blood pressure altering method affects correlation with pulse arrival time
    Heimark, Sondre
    Rindal, Ole Marius H.
    Seeberg, Trine M.
    Stepanov, Alexey
    Boysen, Elin S.
    Botker-Rasmussen, Kasper G.
    Mobaek, Nina K.
    Soraas, Camilla L.
    Stenehjem, Aud E.
    Elmula, Fadl Elmula M. Fadl
    Waldum-Grevbo, Bard
    BLOOD PRESSURE MONITORING, 2022, 27 (02) : 139 - 146
  • [9] PULSE ARRIVAL TIME CAN TRACK CHANGES IN SYSTOLIC BLOOD PRESSURE
    Heimark, Sondre
    Rindal, Ole Marius Hoel
    Seeberg, Trine
    Stepanov, Alexey
    Boysen, Elin Sundby
    Soraas, Camilla Lund
    Stenehjem, Aud -Eldrid
    Elmula, Fadl Elmula Mohamed Fadl
    Waldum-Grevbo, Bard
    JOURNAL OF HYPERTENSION, 2021, 39 : E132 - E132
  • [10] Pulse Arrival Time and Ballistocardiogram Application to Blood Pressure Variability Estimation
    Pinheiro, Eduardo
    Postolache, Octavian
    Girao, Pedro
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 132 - +