Reference Geometry-based Detection of (4D-)CT Motion Artifacts: a Feasibility Study

被引:1
|
作者
Werner, Rene [1 ]
Gauer, Tobias [2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiooncol, Hamburg, Germany
来源
关键词
4D CT; motion artifacts; image registration; image quality; motion analysis; 4D CT DATA;
D O I
10.1117/12.2075853
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Respiration-correlated computed tomography (4D or 3D+ t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data - which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would bene fi t from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from - depending on the threshold - high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about 'ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-) atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy - inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Screening Dependence Study of Superconducting State Parameters of 4d- and 5d- Transition Metals Based Binary Alloys
    Dave, H. P.
    Malan, R. C.
    Vora, A. M.
    ACTA PHYSICA POLONICA A, 2018, 133 (01) : 86 - 93
  • [32] Suppressing Motion Related Artifacts in 4D-CT Or 4D-CBCT Reconstruction Using Projections and Digitally Reconstructed Projections: Proof of Principle
    Yi, B.
    Lasio, G.
    Liu, Y.
    Yu, C.
    Mistry, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 194 - +
  • [33] MOTION-BASED PROJECTION GENERATION FOR 4D-CT RECONSTRUCTION
    Dhou, Salam
    Hugo, Geoffrey D.
    Docef, Alen
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2014, : 1698 - 1702
  • [34] Motion induced dosimetric impacts in breast 3D radiation treatment - a 4D CT based study
    Yue, N.
    Li, X.
    Beriwal, S.
    Heron, D.
    Sontag, M.
    Huq, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2269 - 2269
  • [35] Evaluation of a Novel Sequential 4D Scan Technique for Reduced Motion Artifacts in Respiratory-Gated CT Scans
    Cammin, J.
    Morris, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E367 - E368
  • [36] Evaluation of motion artifacts in 4D-CT simulated from volumetric dynamic CT in non-small cell lung cancer patients
    Young, Heather
    Kempe, Jeff
    Lee, Ting-Yim
    Gaede, Stewart
    MEDICAL PHYSICS, 2021, 48 (08) : 4681 - 4681
  • [37] Laser-speckle-based detection of fluid pulsation in the presence of motion artifacts: in vitro and in vivo study
    Nemati, M.
    Wijshoff, R. W. C. G. R.
    Stijnen, J. M. A.
    van Tuijl, S.
    Bergmans, J. W. M.
    Bhattacharya, N.
    Urbach, H. P.
    OPTICS LETTERS, 2013, 38 (24) : 5334 - 5337
  • [38] Reduction of breathing irregularityrelated motion artifacts in low-pitch spiral 4D CT by optimized projection binning
    Werner, Rene
    Hofmann, Christian
    Muecke, Eike
    Gauer, Tobias
    RADIATION ONCOLOGY, 2017, 12
  • [39] Hypofractionated 4D-PET/CT-based helical tomotherapy for the treatment of lung metastases: A feasibility study
    Di Muzio, N.
    Cattaneo, G. M.
    Mangili, P.
    Tamborra, P.
    Schipani, S.
    Bettinardi, V.
    Landoni, C.
    Danna, M.
    Picchio, M.
    Calandrino, R.
    Fazio, F.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S520 - S521
  • [40] Iterative sorting for 4D CT images based on internal anatomic motion
    Zeng, R.
    Balter, J.
    Fessler, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2388 - 2388