Reference Geometry-based Detection of (4D-)CT Motion Artifacts: a Feasibility Study

被引:1
|
作者
Werner, Rene [1 ]
Gauer, Tobias [2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiooncol, Hamburg, Germany
来源
关键词
4D CT; motion artifacts; image registration; image quality; motion analysis; 4D CT DATA;
D O I
10.1117/12.2075853
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Respiration-correlated computed tomography (4D or 3D+ t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data - which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would bene fi t from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from - depending on the threshold - high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about 'ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-) atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy - inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Modeling respiratory motion for reducing motion artifacts in 4D CT images (vol 40, 041716, 2013)
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Baiter, Peter A.
    Dong, Lei
    MEDICAL PHYSICS, 2015, 42 (11) : 6768 - 6768
  • [12] Validation of non-linear image registration-based correction method for motion artifacts in 4D-CT
    Heath, E.
    Keall, P.
    Collins, L.
    DeBlois, F.
    Seuntjens, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2050 - 2050
  • [13] Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study
    Boye, Dirk
    Lomax, Tony
    Knopf, Antje
    MEDICAL PHYSICS, 2013, 40 (06)
  • [14] Detection of Substances in the Left Atrial Appendage by Spatiotemporal Motion Analysis Based on 4D-CT
    Jin, Cheng
    Yu, Heng
    Feng, Jianjiang
    Wang, Lei
    Lu, Jiwen
    Zhou, Jie
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: ACDC AND MMWHS CHALLENGES, 2018, 10663 : 42 - 50
  • [15] Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans
    Killoran, Joseph H.
    Gerbaudo, Victor H.
    Mamede, Marcelo
    Ionascu, Dan
    Park, Sang-June
    Berbeco, Ross
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 261 - 274
  • [16] Feasibility of differential geometry-based features in detection of anatomical feature points on patient surfaces in range image-guided radiation therapy
    Soufi, Mazen
    Arimura, Hidetaka
    Nakamura, Katsumasa
    Lestari, Fauzia P.
    Haryanto, Freddy
    Hirose, Taka-aki
    Umedu, Yoshiyuki
    Shioyama, Yoshiyuki
    Toyofuku, Fukai
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (11) : 1993 - 2006
  • [17] Feasibility of differential geometry-based features in detection of anatomical feature points on patient surfaces in range image-guided radiation therapy
    Mazen Soufi
    Hidetaka Arimura
    Katsumasa Nakamura
    Fauzia P. Lestari
    Freddy Haryanto
    Taka-aki Hirose
    Yoshiyuki Umedu
    Yoshiyuki Shioyama
    Fukai Toyofuku
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1993 - 2006
  • [18] 4D Predictive Patient-Specific Anatomical Model Based On 4D CT Data: A Feasibility Study
    Guo, B.
    He, W.
    Eom, J.
    De, S.
    Xu, X.
    Shi, C.
    MEDICAL PHYSICS, 2009, 36 (06) : 2501 - +
  • [19] Impact of Motion Artifacts On Image Quality and Accuracy of Tumor Motion Reconstruction in 4D CT-On-Rails and MV-CBCT Scans: A Phantom Study
    Lin, T.
    Ma, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3433 - 3434
  • [20] Experimental quantification and analysis of organ motion artifacts in conventional CT-simulation: Conditions of 4D CT data acquisition
    Zygmanski, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1244 - 1244