One-shot-phase-shifting full range Fourier domain optical coherence tomography by reference wavefront tilting

被引:0
|
作者
Makita, S [1 ]
Yasuno, Y [1 ]
Endo, T [1 ]
Aoki, G [1 ]
Itoh, M [1 ]
Yatagai, T [1 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
关键词
optical coherence tomography; Fourier domain OCT; full range FD-OCT; tilting wavefront; phase-shifting; M-scan; simultaneous detection;
D O I
10.1117/12.589141
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel optical scheme for a full range Fourier domain optical coherence tomography (FD-OCT) is presented. This method avoids a mechanical scan for phase-shifting (mechanical M-scan) which enables a full range FD-OCT. A tilting reference wavefront is used to make variable phase offset of spectral interferometric fringes. Several spectral fringes are detected by a two dimensional CCD camera simultaneously. One axis of the CCD camera is occupied with the optical spectral axis, and the other axis is employed for phase offset variation. A few spectral fringes are extracted and used for phase-shifting algorithm. The principle of this system is confirmed with a plane mirror sample.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [41] One-shot parallel complex Fourier-domain optical coherence tomography using a spatial carrier frequency
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    OPTICAL ENGINEERING, 2008, 47 (05)
  • [42] Theory of Fourier phase within the framework of Fourier-domain optical coherence tomography
    Uttam, Shikhar
    Liu, Yang
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [43] High-speed full range complex Fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    Wei, Xunbin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS III, 2008, 6826
  • [44] Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography
    An, Lin
    Wang, Ruikang K.
    OPTICS LETTERS, 2007, 32 (23) : 3423 - 3425
  • [45] High speed full range complex spectral domain optical coherence tomography
    Götzinger, E
    Pircher, M
    Leitgeb, RA
    Hitzenberger, CK
    OPTICS EXPRESS, 2005, 13 (02): : 583 - 594
  • [46] Image processing in spectral domain optical coherence tomography with phase shifting interferometry
    Gong, Qiang
    Wang, Rui-Kang K
    Ma, Zhen-He
    Zhang, Fan
    Yao, Jian-Quan
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2009, 7 (02): : 168 - 172
  • [47] Single-shot wavelength-independent phase-shifting method for full-field optical coherence tomography
    Zhu, Yue
    Gao, Wanrong
    APPLIED OPTICS, 2019, 58 (04) : 806 - 813
  • [48] Image reconstruction in full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2005, 7 (07): : 350 - 356
  • [49] Robust phase unwrapping for phase images in Fourier domain Doppler optical coherence tomography
    Xia, Shaoyan
    Huang, Yong
    Peng, Shizhao
    Wu, Yanfeng
    Tan, Xiaodi
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (03)
  • [50] Fourier-domain optical coherence tomography based on sinusoidal phase modulation
    Information Optics Laboratory, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
    不详
    不详
    Guangxue Xuebao, 2007, 8 (1470-1474):