One-shot-phase-shifting full range Fourier domain optical coherence tomography by reference wavefront tilting

被引:0
|
作者
Makita, S [1 ]
Yasuno, Y [1 ]
Endo, T [1 ]
Aoki, G [1 ]
Itoh, M [1 ]
Yatagai, T [1 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
关键词
optical coherence tomography; Fourier domain OCT; full range FD-OCT; tilting wavefront; phase-shifting; M-scan; simultaneous detection;
D O I
10.1117/12.589141
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel optical scheme for a full range Fourier domain optical coherence tomography (FD-OCT) is presented. This method avoids a mechanical scan for phase-shifting (mechanical M-scan) which enables a full range FD-OCT. A tilting reference wavefront is used to make variable phase offset of spectral interferometric fringes. Several spectral fringes are detected by a two dimensional CCD camera simultaneously. One axis of the CCD camera is occupied with the optical spectral axis, and the other axis is employed for phase offset variation. A few spectral fringes are extracted and used for phase-shifting algorithm. The principle of this system is confirmed with a plane mirror sample.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [21] Fourier domain optical coherence tomography with ultralong depth range
    Zhihua DING
    Yi SHEN
    Wen BAO
    Peng LI
    Frontiers of Optoelectronics, 2015, 8 (02) : 163 - 169
  • [22] Full range complex spectral domain optical coherence tomography with arbitrary or unknown phase
    Szkulmowski, M
    Bajraszewski, T
    Szkulmowska, A
    Targowski, P
    Kowalczyk, A
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 426 - 429
  • [23] Dynamic full-range Fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    OPTICAL ENGINEERING, 2007, 46 (10)
  • [24] Full-range parallel Fourier-domain optical coherence tomography using sinusoidal phase-modulating interferometry
    Bu, Peng
    Wang, Xiangzhao
    Sasaki, Osami
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2007, 9 (04): : 422 - 426
  • [25] Full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 44 - 53
  • [26] Group-delay-based phase-shifting method for Fourier domain optical coherence tomography
    Cheng, Hsu-Chih
    Huang, Jen-Fa
    Liu, Yi-Cheng
    Chang, Chien-Wen
    Chang, Yao-Tang
    OPTICAL ENGINEERING, 2009, 48 (07)
  • [27] Tissue surface as the reference arm in Fourier domain optical coherence tomography
    Krstajic, Nikola
    Brown, Christian Tom A.
    Dholakia, Kishan
    Giardini, Mario Ettore
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [28] Arbitrary three-phase shifting algorithm for achieving full range spectral optical coherence tomography
    Ma, ZH
    Wang, RKK
    Zhang, F
    Yao, JQ
    CHINESE PHYSICS LETTERS, 2006, 23 (02) : 366 - 369
  • [29] Five-Frame Variable Phase-Shifting Method for Full-Range Spectral-Domain Optical Coherence Tomography
    Lin, Jiewen
    Zhong, Shuncong
    Zhang, Qiukun
    Chen, Weiqiang
    APPLIED SCIENCES-BASEL, 2018, 8 (09):
  • [30] High-sensitive full-range optical vibrometry based on Fourier-domain optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934