Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring

被引:49
|
作者
Maeng, Bohee [1 ]
Chang, Hyung-kwan [1 ]
Park, Jungyul [1 ]
机构
[1] Sogang Univ, Dept Mech Engn, 35 Baekbeom Ro, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
GLAUCOMA; SENSOR; CURVATURE; ANGLE; TONOMETRY; THICKNESS; PEOPLE; NUMBER; RABBIT; EYES;
D O I
10.1039/c9lc01268k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glaucoma is a very common disease after cataracts and is dangerous enough to cause irreversible blindness. However, often the main symptom of glaucoma is difficult to recognize because it may be absent or appear late, so the risk of blindness is greater. Intraocular pressure (IOP) is a well-known primary factor indicating glaucoma. In this study, we demonstrate a smart IOP sensor embedded in a contact lens that works through visual color changes without an external power source such as a battery or RF-based wireless power transfer. A microhydraulic amplification mechanism is adopted to enhance the range of color change from a photonic crystal (PC)-based flexible membrane whose lattice distance between nanostructures varies according to the morphology changes of an eyeball caused by IOP. The performance of the sensor is quantitatively demonstrated using an artificial silicone eye model for in vitro evaluation and a porcine eyeball for ex vivo verification. It has a limit of detection (LOD) of 3.2 and 5.12 mmHg, which was measured and evaluated using a spectrometer and a smartphone camera, respectively. The results prove that our sensor embedded in the contact lens can continuously monitor the IOP change using color change, and a smartphone camera can be used as a quantitative IOP measurement system in a noninvasive manner without an expensive optical spectrometer.
引用
收藏
页码:1740 / 1750
页数:11
相关论文
共 50 条
  • [41] An Ultrasensitive Ti3C2Tx MXene-based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring
    Duan, Zhongyi
    Yuan, Miao
    Liu, Zhiduo
    Pei, Weihua
    Jiang, Kai
    Li, La
    Shen, Guozhen
    SMALL, 2024, 20 (24)
  • [42] Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens
    Lorenz, Katrin
    Korb, Christina
    Herzog, Nicola
    Vetter, Jan M.
    Elflein, Heike
    Keilani, Munir M.
    Pfeiffer, Norbert
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 311 - 316
  • [43] Small core FBG-based temperature compensated ‘smart’ contact lens for effective intraocular pressure measurement
    Chen Y.
    Wang J.
    Zhao Y.
    Liu X.-J.
    Zhang H.
    Murdoch I.
    Hull C.
    Barbur J.
    Sun T.
    Grattan K.V.
    Measurement: Sensors, 2019, 1
  • [44] Recent advances in photonic crystal-based sensors
    Li, Tao
    Liu, Guiju
    Kong, Hao
    Yang, Guozheng
    Wei, Gang
    Zhou, Xin
    COORDINATION CHEMISTRY REVIEWS, 2023, 475
  • [45] A novel photonic crystal-based waveguide modulator
    Poliakov, EY
    Scalora, M
    Bloemer, MJ
    Zheltikov, AM
    LASER PHYSICS, 2005, 15 (11) : 1599 - 1606
  • [46] Special Issue on Photonic Crystal-Based Sensors
    Large, Maryanne
    Cordeiro, Cristiano M. B.
    Andres, Miguel V.
    Matias, Ignacio R.
    IEEE SENSORS JOURNAL, 2010, 10 (07) : 1167 - 1168
  • [47] Microfluidic contact lenses for continuous non-invasive intraocular pressure monitoring
    An, Hongbin
    Chen, Liangzhou
    Liu, Xiaojun
    Zhao, Bin
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [48] The Rectenna Design on Contact Lens for Wireless Powering of the Active Intraocular Pressure Monitoring System
    Cheng, H. W.
    Jeng, B. M.
    Chen, C. Y.
    Huang, H. Y.
    Chiou, J. C.
    Luo, C. H.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3451 - 3454
  • [49] High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring
    Yuan, Miao
    Liu, Zhiduo
    Wu, Xiaoting
    Gou, Haoyang
    Zhang, Yugui
    Ning, Xin
    Li, Weijun
    Yao, Zhaohui
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 354
  • [50] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437