The Rectenna Design on Contact Lens for Wireless Powering of the Active Intraocular Pressure Monitoring System

被引:0
|
作者
Cheng, H. W. [1 ]
Jeng, B. M. [1 ]
Chen, C. Y. [1 ]
Huang, H. Y. [2 ]
Chiou, J. C. [3 ]
Luo, C. H. [1 ]
机构
[1] Natl Cheng Kung Univ, Tainan 701, Taiwan
[2] Natl Taipei Univ, Taipei, Taiwan
[3] Natl Chiao Tung Univ, Hsinchu 300, Taiwan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.
引用
收藏
页码:3451 / 3454
页数:4
相关论文
共 50 条
  • [1] Design of wireless contact-lens antenna for intraocular pressure monitoring
    Priya, L.
    Vijitha, J.
    Alagappan, M.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) : 315 - 323
  • [2] A Contact Lens Sensor System with a Micro-Capacitor for Wireless Intraocular Pressure Monitoring
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    Yang, Tzu-Sen
    Chiou, Jin-Chern
    2013 IEEE SENSORS, 2013, : 203 - 206
  • [3] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Joohee Kim
    Jihun Park
    Young-Geun Park
    Eunkyung Cha
    Minjae Ku
    Hyeon Seok An
    Kyoung-Pil Lee
    Man-Il Huh
    Junmo Kim
    Taek-Soo Kim
    Dai Woo Kim
    Hong Kyun Kim
    Jang-Ung Park
    Nature Biomedical Engineering, 2021, 5 : 772 - 782
  • [4] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Kim, Joohee
    Park, Jihun
    Park, Young-Geun
    Cha, Eunkyung
    Ku, Minjae
    An, Hyeon Seok
    Lee, Kyoung-Pil
    Huh, Man-Il
    Kim, Junmo
    Kim, Taek-Soo
    Kim, Dai Woo
    Kim, Hong Kyun
    Park, Jang-Ung
    NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) : 772 - 782
  • [5] Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma
    Kim, Tae Yeon
    Mok, Jee Won
    Hong, Sang Hoon
    Jeong, Sang Hoon
    Choi, Hyunsik
    Shin, Sangbaie
    Joo, Choun-Ki
    Hahn, Sei Kwang
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [6] Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma
    Tae Yeon Kim
    Jee Won Mok
    Sang Hoon Hong
    Sang Hoon Jeong
    Hyunsik Choi
    Sangbaie Shin
    Choun-Ki Joo
    Sei Kwang Hahn
    Nature Communications, 13
  • [7] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [8] Wearable contact lens sensor for intraocular pressure monitoring
    Fan, Yanyan
    Tu, Hailing
    Zhao, Hongbin
    Wei, Feng
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 22 - 22
  • [9] Hydrogel-Based Smart Contact Lens for Highly Sensitive Wireless Intraocular Pressure Monitoring
    Zhu, Hengtian
    Yang, Huan
    Zhan, Liuwei
    Chen, Ye
    Wang, Junming
    Xu, Fei
    ACS SENSORS, 2022, 7 (10) : 3014 - 3022
  • [10] Design of a Wireless Intraocular Pressure Monitoring System for a Glaucoma Drainage Implant
    Kakaday, T.
    Plunkett, M.
    McInnes, S.
    Li, J. S. Jimmy
    Voelcker, N. H.
    Craig, J. E.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 198 - +