FETAX interlaboratory validation study: Phase III, part 1 testing

被引:0
|
作者
Bantle, JA
Finch, RA
Burton, DT
Fort, DJ
Dawson, DA
Linder, G
Rayburn, JR
Hull, M
KumsherKing, M
GaudetHull, AM
Turley, SD
机构
[1] USA, BIOMED RES & DEV LAB, FREDERICK, MD 21702 USA
[2] UNIV MARYLAND, WYE RES & EDUC CTR, QUEENSTOWN, MD 21658 USA
[3] STOVER BIOMETR LABS INC, STILLWATER, OK 74076 USA
[4] ASHLAND UNIV, DEPT BIOL & TOXICOL, ASHLAND, OH 44805 USA
[5] MANTECH ENVIRONM RES LAB, CORVALLIS, OR 97333 USA
[6] USA, BIOMED RES & DEV LAB, GEO CTR INC, FREDERICK, MD 21702 USA
关键词
FETAX; Xenopus; teratogen; monosodium glutamate; ascorbic acid; P-aminopropionitrile; sodium acetate; sodium arsenate; copper sulfate; interlaboratory validation; developmental toxicity;
D O I
暂无
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The Frog Embryo Teratogenesis Assay-Xenopus (FETAX) is a 96-h whole embryo developmental toxicity screening assay that can be used in ecotoxicology and in detecting mammalian developmental toxicants when an in vitro metabolic activation system is employed, A standardized American Society for Testing and Materials (ASTM) guide for the conduct of FETAX has been published, along with a companion atlas that aids in embryo staging and identifying malformations, As part of the ASTM process, a three-phase interlaboratory validation study was undertaken to evaluate the repeatability and reliability of FETAX, Seven different participants collaborated in the study, In Phase I, FETAX proved to be more repeatable and reliable than many bioassays, However, some excessive variation was observed in a few laboratories, An initial lack of assay experience by some technicians caused variation, Phase II showed far less intra- and interlaboratory variability than Phase I, Non-teratogens showed the most consistent results, while more variability was observed for the two teratogens tested, Interlaboratory coefficient of variation values for all endpoints ranged from 7.3 to 54.7, Phase III-Part 1, using coded samples and test concentration ranges selected by each laboratory, showed results similar to Phase I, Analysis of the causes of variation suggested that some technicians judged some embryos to be malformed while others consistently judged similar embryos as normal, Concentration ranges tested by some of the laboratories varied greatly and a new protocol for selecting concentrations for initial testing was written to reduce variation from this source, Testing to date suggests that FETAX is as repeatable and reliable as other standard bioassays.
引用
收藏
页码:517 / 528
页数:12
相关论文
共 50 条
  • [31] The functional testing of chromatographic software as part of computer validation
    Hayes, TL
    Kohne, JW
    Miller, TL
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1995, 13 (12): : 960 - &
  • [32] Assessment of opioid surrogates for spectroscopic testing (Part III)
    Daniels, Grant C.
    Whitener Jr, Keith E.
    Smith, Charles D.
    Giordano, Braden C.
    Collins, Greg E.
    FORENSIC CHEMISTRY, 2022, 30
  • [33] WEC-SIM PHASE 1 VALIDATION TESTING - NUMERICAL MODELING OF EXPERIMENTS
    Ruehl, Kelley
    Michelen, Carlos
    Bosma, Bret
    Yu, Yi-Hsiang
    PROCEEDINGS OF THE ASME 35TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING , 2016, VOL 6, 2016,
  • [34] Interlaboratory Study to Evaluate a Testing Protocol for the Safety of Food Packaging Coatings
    Marin-Kuan, Maricel
    Pagnotti, Vincent
    Patin, Amaury
    Moulin, Julie
    Latado, Helia
    Varela, Jesus
    Hammel, Yves-Alexis
    Gude, Thomas
    Moor, Heidi
    Billinton, Nick
    Tate, Matthew
    Behnisch, Peter Alexander
    Besselink, Harrie
    Burleigh-Flayer, Heather
    Koster, Sander
    Szabo, David T.
    TOXICS, 2023, 11 (02)
  • [35] EAL interlaboratory comparison Wa1 -: Testing of potable water
    Haapala, K
    Lattunen, H
    Mäkinen, I
    ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (12) : 485 - 487
  • [36] EAL interlaboratory comparison Wa1 – Testing of potable water
    K. Haapala
    Hanna Lattunen
    Irma Mäkinen
    Accreditation and Quality Assurance, 1998, 3 : 485 - 487
  • [37] Interlaboratory study of standard methods for testing multiwire steel prestressing strand
    Lequesne, Rémy D.
    Collins, William N.
    Lucon, Enrico
    Darwin, David
    Poudel, Ashwin
    PCI Journal, 2020, 65 (04): : 71 - 86
  • [38] Intra- and interlaboratory study of a method for testing the antifungal susceptibilities of dermatophytes
    Ghannoum, MA
    Chaturvedi, V
    Espinel-Ingroff, A
    Pfaller, MA
    Rinaldi, MG
    Lee-Yang, W
    Warnock, DW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (07) : 2977 - 2979
  • [39] Interlaboratory study of standard methods for testing multiwire steel prestressing strand
    Lequesne, Remy D.
    Collins, William N.
    Lucon, Enrico
    Darwin, David
    Poudel, Ashwin
    PCI JOURNAL, 2020, 65 (04): : 71 - 86
  • [40] An International Interlaboratory Study of Complex Variant Detection in Clinical Genetic Testing
    Lincoln, S.
    Fellowes, A.
    Chowhurdy, S.
    Mahamdallie, S.
    Klee, E.
    Truty, R.
    Zook, J.
    Kingsmore, S.
    Ferber, M.
    Salit, M.
    Nussbaum, R.
    Shirts, B.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (05): : S17 - S18