Reliability assessment of axially loaded uPVC tube confined reinforced concrete columns

被引:8
|
作者
Woldemariam, Abraham Mengesha [1 ]
Oyawa, Walter O. [2 ]
Nyomboi, Timothy [3 ,4 ]
机构
[1] Pan African Univ, Civil Engn Dept, Inst Basic Sci Technol & Innovat PAUSTI, 62000 JKUAT, Nairobi 00200, Kenya
[2] JKUAT, Civil Const & Engn Dept, 62000 JKUAT, Nairobi 00200, Kenya
[3] PAUSTI, Dept Civil & Struct Engn, 62000 JKUAT, Nairobi 00200, Kenya
[4] Kenya Urban Rd Author, 62000 JKUAT, Nairobi 00200, Kenya
关键词
Confined concrete; Failure Probability; Reliability index; Strength reduction factor; Subset simulation; uPVC confinement; MCMC; SUBSET SIMULATION; STRENGTH; 1ST-ORDER; BEHAVIOR;
D O I
10.1016/j.istruc.2019.11.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Un-plasticized polyvinyl chloride (uPVC) tubes are increasingly used as stay-in-place formwork and protection for reinforced concrete columns from chemical attacks, peeling of concrete cover and corrosion of steel in a harsh environment. The provision of uPVC lateral confinement to the concrete improves the strength, ductility and energy absorption of the columns. However, since there is no available design guideline for uPVC tube confined concrete columns, the contribution of uPVC confinement to the column resistance has not been considered during the design stage. In this study, the strength reduction factor 4) provided by ACI 318-14 for a reinforced concrete column with circular tie reinforcement is modified to account for uPVC confinement for application in design. The subset simulation method was applied to assess the effect of uPVC confinement on the reliability of uPVC confined concrete columns. Based on the reliability study, a new strength reduction factor was proposed for uPVC confined reinforced concrete columns. Additionally, the effect of column variables on the reliability index was also investigated. The result shows that the additional uncertainties associated with the uPVC material properties and the peak strength model have an effect on the strength reduction factor. Therefore, the strength reduction factor needs to be reduced to achieve the same reliability level of the unconfined column. However, for the same design load used, the reliability index and strength reduction factor increased from 4.03 to 4.53 and 0.65 to 0.75, respectively as the 2t/D ratio increases from 0 to 0.04. Therefore, a strength reduction factor (phi) of 0.75 can be used instead of 0.65 to design a reinforced concrete column according to ACI 318-14 if the uPVC tube is going to be used as stay-in-place formwork; otherwise, the new proposed model can be used to calculate the strength reduction factor and design a uPVC confined concrete column according to ACI 318-14.
引用
收藏
页码:529 / 538
页数:10
相关论文
共 50 条
  • [41] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    Lu Yi-yan
    Li Na
    Li Shan
    Liang Hong-jun
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (06) : 2287 - 2296
  • [42] Probabilistic assessment of FRP-confined reinforced concrete columns
    Baji, Hassan
    Ronagh, Hamid Reza
    Li, Chun-Qing
    COMPOSITE STRUCTURES, 2016, 153 : 851 - 865
  • [43] Assessment for behavior of axially loaded reinforced concrete columns strengthened by different patterns of steel-framed jacket
    Shhatha, Muaid Adnan
    Mahdi, Waseem H. H.
    Alalikhan, Ahmed A. A.
    OPEN ENGINEERING, 2023, 13 (01):
  • [44] Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect
    Hu, HT
    Huang, CS
    Wu, MH
    Wu, YM
    JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (10) : 1322 - 1329
  • [45] Effects of concrete quality control on the reliability assessment of reinforced concrete columns
    Magalhaes, Fabio Costa
    Real, Mauro de Vasconcellos
    Pinto da Silva Filho, Luiz Carlos
    MATERIA-RIO DE JANEIRO, 2018, 23 (03):
  • [46] Behaviours of concentrically and eccentrically loaded square steel tube confined reinforced concrete slender columns after fire exposure
    Liu, Faqi
    Yang, Hua
    Wang, Wei
    THIN-WALLED STRUCTURES, 2021, 158
  • [47] Mechanical performance of axially loaded reinforced concrete columns wrapped with carbon fiber sheet
    Li, Chenchen
    Gao, Danying
    Huang, Chunshui
    ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 1847 - 1859
  • [48] Behavior of axially loaded low strength concrete columns reinforced with GFRP bars and spirals
    El-Gamal, Sherif
    AlShareedah, Othman
    ENGINEERING STRUCTURES, 2020, 216 (216)
  • [49] New steel jacket for retrofitting of axially loaded circular reinforced concrete short columns
    Abdelfattah, Fathy Abdelmoniem
    Abdo, Aly A.H. Aly
    AEJ - Alexandria Engineering Journal, 1999, 38 (03):
  • [50] Influence of slenderness on axially loaded square tubed steel-reinforced concrete columns
    Yan, Biao
    Gan, Dan
    Zhou, Xuhong
    Zhu, Weiqing
    STEEL AND COMPOSITE STRUCTURES, 2019, 33 (03): : 375 - 388