Reliability assessment of axially loaded uPVC tube confined reinforced concrete columns

被引:8
|
作者
Woldemariam, Abraham Mengesha [1 ]
Oyawa, Walter O. [2 ]
Nyomboi, Timothy [3 ,4 ]
机构
[1] Pan African Univ, Civil Engn Dept, Inst Basic Sci Technol & Innovat PAUSTI, 62000 JKUAT, Nairobi 00200, Kenya
[2] JKUAT, Civil Const & Engn Dept, 62000 JKUAT, Nairobi 00200, Kenya
[3] PAUSTI, Dept Civil & Struct Engn, 62000 JKUAT, Nairobi 00200, Kenya
[4] Kenya Urban Rd Author, 62000 JKUAT, Nairobi 00200, Kenya
关键词
Confined concrete; Failure Probability; Reliability index; Strength reduction factor; Subset simulation; uPVC confinement; MCMC; SUBSET SIMULATION; STRENGTH; 1ST-ORDER; BEHAVIOR;
D O I
10.1016/j.istruc.2019.11.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Un-plasticized polyvinyl chloride (uPVC) tubes are increasingly used as stay-in-place formwork and protection for reinforced concrete columns from chemical attacks, peeling of concrete cover and corrosion of steel in a harsh environment. The provision of uPVC lateral confinement to the concrete improves the strength, ductility and energy absorption of the columns. However, since there is no available design guideline for uPVC tube confined concrete columns, the contribution of uPVC confinement to the column resistance has not been considered during the design stage. In this study, the strength reduction factor 4) provided by ACI 318-14 for a reinforced concrete column with circular tie reinforcement is modified to account for uPVC confinement for application in design. The subset simulation method was applied to assess the effect of uPVC confinement on the reliability of uPVC confined concrete columns. Based on the reliability study, a new strength reduction factor was proposed for uPVC confined reinforced concrete columns. Additionally, the effect of column variables on the reliability index was also investigated. The result shows that the additional uncertainties associated with the uPVC material properties and the peak strength model have an effect on the strength reduction factor. Therefore, the strength reduction factor needs to be reduced to achieve the same reliability level of the unconfined column. However, for the same design load used, the reliability index and strength reduction factor increased from 4.03 to 4.53 and 0.65 to 0.75, respectively as the 2t/D ratio increases from 0 to 0.04. Therefore, a strength reduction factor (phi) of 0.75 can be used instead of 0.65 to design a reinforced concrete column according to ACI 318-14 if the uPVC tube is going to be used as stay-in-place formwork; otherwise, the new proposed model can be used to calculate the strength reduction factor and design a uPVC confined concrete column according to ACI 318-14.
引用
收藏
页码:529 / 538
页数:10
相关论文
共 50 条
  • [31] Use of advanced composite materials in strengthening axially loaded reinforced concrete columns
    Cheikh-Zouaoui M.
    Benzaid R.
    Chikh N.
    Mesbah H.A.
    Cheikh-Zouaoui, M. (czmustapha@yahoo.fr), 1600, Elsevier B.V., Netherlands (29): : e187 - e191
  • [32] NUMERICAL-SIMULATION OF THE BEHAVIOR OF AXIALLY LOADED REINFORCED-CONCRETE COLUMNS
    MAU, ST
    COMPUTERS & STRUCTURES, 1990, 35 (04) : 361 - 368
  • [33] Performance of axially loaded reinforced concrete rectangular columns strengthened with GFRP strips
    Madupu, L. N. K. Sai
    Ram, K. S. Sai
    MATERIALS TODAY-PROCEEDINGS, 2021, 43 : 1784 - 1791
  • [34] Ultimate torsional capacity of steel tube confined reinforced concrete columns
    Nie, Xin
    Wang, Wei
    Wang, Yu-Hang
    Yu, Jie
    Hou, Chao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 : 207 - 222
  • [35] Experimental Study on Axially-Loaded Concrete Columns with Various Sizes Confined by CFRP
    Long, Yue-Ling
    Zhu, Jiang
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 706 - +
  • [36] Finite element analysis of axially loaded FRP-confined rectangular concrete columns
    Lo, S. H.
    Kwan, A. K. H.
    Ouyang, Y.
    Ho, J. C. M.
    ENGINEERING STRUCTURES, 2015, 100 : 253 - 263
  • [37] Experimental Research on Axially Loaded Circular Concrete Columns Confined by CFRP under Preload
    Pan, Yi
    Cao, Shuangyin
    Jing, Denghu
    Zhao, Shichun
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 694 - +
  • [38] Design equations for axially loaded reinforced concrete columns strengthened with fibre reinforced polymer wraps
    Thériault, M
    Neale, KW
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (05) : 1011 - 1020
  • [39] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    Yi-yan Lu
    Na Li
    Shan Li
    Hong-jun Liang
    Journal of Central South University, 2015, 22 : 2287 - 2296
  • [40] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    卢亦焱
    李娜
    李杉
    梁鸿骏
    Journal of Central South University, 2015, 22 (06) : 2287 - 2296