An experimental investigation of propane/isobutane mixtures as alternative refrigerants in compression refrigeration machines

被引:5
|
作者
Venzik, V. [1 ]
Roskosch, D. [1 ]
Atakan, B. [1 ]
机构
[1] Univ Duisburg Essen, Thermodynam, IVG, Fak Ingenieurwissensch, Lotharstr 1, D-47048 Duisburg, Germany
来源
关键词
HEAT-PUMP; PERFORMANCE; FLUID; REPLACEMENT; PROPANE; WORKING; CYCLES; R152A;
D O I
10.1007/s10010-019-00389-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Due to political regulations, the currently used refrigerants (e.g., R134a) have to be replaced by fluids with reduced greenhouse warming potential (GWP) in future. Natural refrigerants such as isobutane (R600a) or propane (R290) are such fluids; they are environmentally friendly, inexpensive, available in large quantities and have good thermodynamic properties. If isobutane and propane are mixed, a zeotropic mixture results. Based on basic thermodynamic theory, the non-isothermal phase change of zeotropic mixtures leads to reduced exergy losses in the heat exchangers and thus, to an increased coefficient of performance (COP). Apart from the changes in the heat exchangers, all other process components are also influenced by the mixture composition. This usually remains unconsidered in the large number of theoretical studies. To improve and validate theoretical models, a vapour-compression heat pump test rig was set up. The test rig allows the systematic investigation of different pure fluids and fluid mixtures. In addition, extensive measurement equipment is installed to measure mass flows rates, temperature profiles and pressure levels. Based on these measured values, all important process variables can be derived, such as the COP and the compressor power input as a function of the mixture composition. In this study, the pure fluids isobutane and propane as well as their mixtures are investigated. Discussed parameters are the COP, the isentropic compressor efficiencies, the specific compressor work as well as the temperature glide as a function of the evaporation temperature (0 to 6 degrees C), for a constant condensation temperature of 30 degrees C, at different compressor power and rotation speeds (1050, 1500 and 2100min-1). For steady state conditions the results show that the use of a zeotropic mixture increases the COP compared to the respective pure fluids. The highest COPs are achieved at a composition of xPropane = 0.732; xIsobutane = 0.268 and are between 3.3 and 5.4 depending on the operating conditions. Compared to theory, the experimental results for the mixture xPropane = 0.732; xIsobutane = 0.268 show only slight improvements of the COPs by 5% compared to pure propane. A more detailed analysis shows that mainly two aspects influence the process efficiency. On the one hand the isentropic efficiency of the compressor, which depends strongly on the composition and on the other hand, the pressure losses in the heat exchangers reduce the efficiency. Especially the pressure losses in the evaporator reduces the actually usable temperature glide. These effects are usually not taken into account in simple theoretical approaches.
引用
收藏
页码:65 / 77
页数:13
相关论文
共 50 条
  • [41] Experimental investigation on the near detonation limits of propane/hydrogen/oxygen mixtures in a rectangular tube
    Zhang Yun
    Cheng Yang-Fan
    Su Jian
    Wang Wen-Tao
    Han Ti-Fei
    Tan Ying-Xin
    Cao Wei-Guo
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (01) : 1107 - 1113
  • [42] Energy and Thermal Conductivity Assessment of Dimethyl-Ether and its Azeotropic Mixtures as Alternative Low Global Warming Potential Refrigerants in a Refrigeration System
    Bolaji, Bukola Olalekan
    Oyelaran, Olatunde Ajani
    Abiala, Israel Olutunji
    Ogundana, Tunde Oluwatoyin
    Amosun, Semiu Taiwo
    [J]. ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2021, 25 (01) : 12 - 28
  • [43] Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants
    La Rocca, Vincenzo
    Panno, Giuseppe
    [J]. APPLIED ENERGY, 2011, 88 (08) : 2809 - 2815
  • [44] Experimental investigation of a pilot compression chiller with alternatives refrigerants R401a and R134a
    Fatouh, M.
    [J]. Proceedings of the ASME Advanced Energy Systems Division, 2005, 45 : 43 - 51
  • [45] Experimental study of R290/R600a mixtures in vapor compression refrigeration system
    Ozsipahi, Mustafa
    Kose, Haluk Anil
    Kerpicci, Husnu
    Gunes, Hasan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 247 - 258
  • [46] Experimental investigation of integrated refrigeration system (IRS) with gas engine, compression chiller and absorption chiller
    Sun, Z. G.
    [J]. ENERGY, 2008, 33 (03) : 431 - 436
  • [47] EXPERIMENTAL INVESTIGATION OF THE CONDENSATION OF BINARY-MIXTURES OF FREON-11 AND REFRIGERATION LUBE OILS
    ABUEISHAH, SI
    ABOUARAB, TW
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING FLUID MECHANICS, 1990, 3 (04): : 363 - 382
  • [48] Experimental and numerical investigation of a compact vapor compression refrigeration system for cooling of avionics in harsh environments
    Erkinaci, Tayfun
    Coskun, Fethiye
    Cotur, Aykut
    Onler, Recep
    Serincan, Mustafa Fazil
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236
  • [49] EXPERIMENTAL INVESTIGATION OF NANO COMPRESSOR OIL EFFECT ON THE COOLING PERFORMANCE OF A VAPOR-COMPRESSION REFRIGERATION SYSTEM
    Selimefendigil, F.
    Bingolbali, T.
    [J]. JOURNAL OF THERMAL ENGINEERING, 2019, 5 (01): : 100 - 104
  • [50] EXPERIMENTAL INVESTIGATION OF PERFORMANCE EFFECT OF WORKING PARAMETERS ON BI-EVAPORATOR COMPRESSION /EJECTION REFRIGERATION SYSTEM
    Liu, Huadong
    Wei, Xinli
    Wang, Zhenzhen
    Geng, Lihong
    Li, Chunhe
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE JOINT WITH ICOPE-17, 2017, VOL 2, 2017,