Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants

被引:55
|
作者
La Rocca, Vincenzo [1 ]
Panno, Giuseppe [1 ]
机构
[1] Univ Palermo, Dipartimento Ric Energet & Ambientali DREAM, I-90128 Palermo, Italy
关键词
R22; Alternative refrigerants; R417A; R422A; R422D;
D O I
10.1016/j.apenergy.2011.01.051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the results of an experimental analysis comparing the performance of a vapour compression refrigerating unit operating with R22, and its performance in comparison to a new HFC fluid, substituting the former according to Regulation No 2037/2000. In particular, the plant working efficiency was first tested with R22 and then with three new HFC fluids: R417A, R422A and R422D. The investigation verified that despite the case of substitution and the advantage of being able to continue to use mineral oil as a lubricant in the compressor, the performance with the new tested fluids did not result as efficient as when using R22. (C) 201 1 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2809 / 2815
页数:7
相关论文
共 50 条