Immunity measurements using strip transmission. lines and family of TEM cells

被引:0
|
作者
Sathyamurthy, S [1 ]
机构
[1] Combat Vehicles Res & Dev Estab, Madras 600054, Tamil Nadu, India
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Immunity measurements (both commercial and military testing) using basic strip transmission lines system and TEM family of cells / enclosures are surveyed in this paper. Measurement requirements and choice of test fixtures/jigs available are explained in brief. Frequency ranges, field-generating capabilities, techniques involved are briefly discussed w.r.t type of application areas. Operational difficulties in meeting test requirements are also discussed. Finally a comparison on device options versus performance objectives are brought out in this paper for three different requirements. Suggestions for various options / test configurations are indicated in light of recent revisions of standards on immunity testing requirements in EMI/EMC.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [31] A Ka-band CMOS Wilkinson power divider using synthetic Quasi-TEM transmission lines
    Chiang, Meng-Ju
    Wu, Hsien-Shun
    Tzuang, Ching-Kuang C.
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2007, 17 (12) : 837 - 839
  • [32] Frequency-dependent modeling of transmission lines using bergeron cells
    Noda, Taku
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 12 : S23 - S30
  • [33] INTERCOMPARISON OF PERMITTIVITY MEASUREMENTS USING THE TRANSMISSION/REFLECTION METHOD IN 7-MM COAXIAL TRANSMISSION-LINES
    VANZURA, EJ
    BAKERJARVIS, JR
    GROSVENOR, JH
    JANEZIC, MD
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1994, 42 (11) : 2063 - 2070
  • [34] Accurate Location of Evolving Faults on Transmission Lines Using Sparse Wide Area Measurements
    Jiao, Xiangqing
    Liao, Yuan
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2018, 19 (01):
  • [35] Fault location scheme for multi-terminal transmission lines using unsynchronized measurements
    Hussain, Shoaib
    Osman, A. H.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 : 277 - 284
  • [36] New accurate fault location algorithm for parallel transmission lines using local measurements
    Chaiwan, Pramote
    Kang, Ning
    Liao, Yuan
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 : 68 - 73
  • [37] Extraction of the frequency-dependent characteristic impedance of transmission lines using TDR measurements
    Kim, W
    Swaminathan, M
    Li, YL
    PROCEEDINGS OF 3RD ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2000, : 191 - 197
  • [38] A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas
    Shimul Saha
    Helena Cano-Garcia
    Ioannis Sotiriou
    Oliver Lipscombe
    Ioannis Gouzouasis
    Maria Koutsoupidou
    George Palikaras
    Richard Mackenzie
    Thomas Reeve
    Panagiotis Kosmas
    Efthymios Kallos
    Scientific Reports, 7
  • [39] New radiated immunity/susceptibility test method using four-septum TEM cell: Measurements and field analysis
    Murano, Kimitoshi
    Kawahara, Hiroko
    Tayarani, Majid
    Xiao, Fengchao
    Kami, Yoshio
    2007 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY: WORKSHOP AND TUTORIAL NOTES, VOLS 1-3, 2007, : 719 - +
  • [40] A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch Antennas
    Saha, Shimul
    Cano-Garcia, Helena
    Sotiriou, Loannis
    Lipscombe, Oliver
    Gouzouasis, Ioannis
    Koutsoupidou, Maria
    Palikaras, George
    Mackenzie, Richard
    Reeve, Thomas
    Kosmas, Panagiotis
    Kallos, Efthymios
    SCIENTIFIC REPORTS, 2017, 7