Blood velocity measurement in healthy and diseased carotid arteries by vector Doppler techniques

被引:0
|
作者
Lenge, Matteo [1 ,2 ,3 ,4 ,5 ,6 ]
Righi, Daniele [7 ]
Ricci, Stefano [1 ]
Liebgottt, Herve [2 ,3 ,4 ,5 ,6 ]
Tortoli, Piero [1 ]
机构
[1] Univ Florence, Dept Informat Engn, Florence, Italy
[2] Univ Lyon, CREATIS, Villeurbanne, France
[3] CNRS, UMR 5220, Villeurbanne, France
[4] INSERM, U1044, Villeurbanne, France
[5] Univ Lyon 1, F-69622 Villeurbanne, France
[6] INSA Lyon, F-69622 Villeurbanne, France
[7] AOU Careggi, Heart & Vessels Dept, Florence, Italy
关键词
Doppler ultrasound; Vector flow; blood velocity estimation; peak systolic velocity; Real-time; PLANE-WAVES; FLOW; ULTRASOUND;
D O I
10.1109/ULTSYM.2014.0085
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vector Doppler (VD) methods are increasingly attractive for the capability of providing angle-independent blood velocity measurements. This may be particularly important in carotid artery peak systolic velocity (PSV) measurements, which are widely used for stenosis assessments. Here, two recently introduced VD techniques have been compared to the classic spectral Doppler approach through 37 PSV measurements in common carotid arteries (CCAs) and internal carotid arteries (ICAs) of healthy volunteers and of patients with different degrees of stenosis. The PSVs measured by the two VD techniques were very close to each other for both CCAs and ICAs (0.83 slope coefficient and 7 cm/s intercept value, according to the linear regression analysis). Comparing any of the two VD techniques to the classic method provided a (0.42/0.46) regression coefficient with a (14/20) cm/s intercept value. The high correlation obtained with the two VD techniques supports their suitability to perform accurate PSV measurements in carotid arteries.
引用
收藏
页码:345 / 348
页数:4
相关论文
共 50 条
  • [41] Three-dimensional vector velocity measurement in optical doppler tomography
    Meng, Jie
    Ding, Zhihua
    Zhu, Ying
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (11): : 3168 - 3172
  • [42] Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography
    Qi, Li
    Zhu, Jiang
    Hancock, Aneeka M.
    Dai, Cuixia
    Zhang, Xuping
    Frostig, Ron D.
    Chen, Zhongping
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02): : 601 - 615
  • [43] TRANSCRANIAL MEASUREMENT OF BLOOD VELOCITIES IN THE BASAL CEREBRAL-ARTERIES USING PULSED DOPPLER ULTRASOUND - VELOCITY AS AN INDEX OF FLOW
    KIRKHAM, FJ
    PADAYACHEE, TS
    PARSONS, S
    SEARGEANT, LS
    HOUSE, FR
    GOSLING, RG
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (01): : 15 - 21
  • [44] PULSED DOPPLER TECHNIQUES FOR MEASURING INSTANTANEOUS MAXIMUM AND MEAN FLOW VELOCITIES IN CAROTID ARTERIES
    LINDEGAARD, KF
    BAKKE, SJ
    GRIP, A
    NORNES, H
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (04): : 419 - 426
  • [45] Colour velocity flow measurement: In vitro validation and application to human carotid arteries
    Deane, CR
    Markus, HS
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03): : 447 - 452
  • [46] MEASUREMENT OF FLOW VELOCITY IN THE CAROTID BIFURCATION MODELS USING MULTI-ANGLE COMPOUND CROSS-BEAM VECTOR DOPPLER
    Wang, Kang-yu
    Zhou, Yu-liu
    He, Li-yuan
    Lu, Chun-yao
    Yu, Run
    Wu, Da-wei
    PROCEEDINGS OF THE 2020 15TH SYMPOSIUM ON PIEZOELECTRCITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2021, : 156 - 159
  • [47] ECG-TRIGGERED MR BLOOD-FLOW VELOCITY-MEASUREMENT IN THE CAROTID ARTERIES - COMPARISON WITH DUPLEX SONOGRAPHY
    SEIDERER, M
    KRONER, KK
    MULLER, E
    SPENGEL, F
    DIGITALE BILDDIAGNOSTIK, 1988, 8 (03): : 110 - 114
  • [48] BLOOD VELOCITY PATTERNS IN HEALTHY SUBJECTS AND PATIENTS WITH CARDIOMYOPATHY: A NEW ECHO TOOL USING DOPPLER VECTOR FLOW MAPPING
    Garcia, D.
    Le Tarnec, L.
    Sharestan, J.
    Auger, D.
    Tournoux, F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S270 - S270
  • [49] Dynamic signal energy quantified from simultaneous recordings of pressure and Doppler velocity in diseased human coronary arteries
    Kolyva, Christina
    Spaan, Jos A. E.
    Verhoeff, Bart-Jan
    Piek, Jan J.
    Siebes, Maria
    FASEB JOURNAL, 2007, 21 (06): : A1228 - A1228
  • [50] Tapered Vector Doppler for Improved Quantification of Low Velocity Blood Flow
    Ekroll, Ingvild Kinn
    Perrot, Vincent
    Liebgott, Herve
    Avdal, Jorgen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1017 - 1031