Colour velocity flow measurement: In vitro validation and application to human carotid arteries

被引:39
|
作者
Deane, CR [1 ]
Markus, HS [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,DEPT NEUROL,LONDON SE5 9RS,ENGLAND
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1997年 / 23卷 / 03期
关键词
ultrasonics; carotid artery; cerebral blood flow; DOPPLER ULTRASOUND; BLOOD-FLOW;
D O I
10.1016/S0301-5629(96)00224-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound measurement of volume blood flow is potentially useful for many clinical situations, yet practical implementation and use are restricted by the many instrumentation and blood flow limitations that can arise. Colour velocity imaging offers a number of theoretical advantages over methods based on duplex imaging. We evaluated a colour velocity flow measurement system (CVI-Q, Philips) both in a flow phantom and in vivo in the extracranial carotid arteries of normal volunteers. Over a range of constant (50-1200 ml/min) and pulsatile (92-366 ml/min) flows and using both steered and unsteered beams with beam angles of 30 degrees and 40 degrees, errors usually within 5% were obtained for constant flow and within 10% for pulsatile flow. However, with a beam angle of 70 degrees, higher errors of 20% were obtained for pulsatile flow. The reproducibility of flow measurements made using both anterior and posterior-lateral scanning approaches was determined in the common (CCA), internal (ICA) and external carotid (EGA) arteries of 18 volunteers. A greater reproducibility was found using the posterior-lateral approach (CCA 6.27%; ICA 9.8%), and mean (SD) flow values were 376 ml/min in the CCA and 255 ml/min in the ICA. The ratio of (ICA + ECA)/CCA flow calculated for each subject individually was mean (SD) 0.95 (0.11). Insonation from an anterior approach resulted in lower reproducibility and lower flow values. In conclusion, colour flow velocity imaging allows repeatable reproducible measurements of CCA and ICA flow, but results are optimal if a posterior-lateral scanning approach is used. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:447 / 452
页数:6
相关论文
共 50 条
  • [1] Cerebral blood flow measurement by colour velocity imaging in radiation induced carotid stenosis
    Lam, WW
    Ho, S
    Leung, S
    Wong, KS
    Metreweli, C
    RADIOLOGY, 2001, 221 : 297 - 297
  • [2] Application of two-colour PIV to in-cylinder flow velocity measurement
    Towers, DP
    Buckberry, CH
    INTERNATIONAL SEMINAR ON OPTICAL METHODS AND DATA PROCESSING IN HEAT AND FLUID FLOW, 1996, 1996 (03): : 211 - 220
  • [3] Measurement of blood flow velocity waveforms in the carotid, brachial and femoral arteries during postural change
    Azhim, Azran
    Katai, Mizuki
    Akutagawa, Masatake
    Hirao, Yuji
    Yoshizaki, Kazuo
    Obara, Shigeru
    Nomura, Masaharu
    Tanaka, Hiroyuki
    Yamaguchi, Hisao
    Kinouchi, Yohsuke
    2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2, 2006, : 429 - +
  • [4] BRAIN ARTERIES CAPACITY FOR AUTOREGULATION AND FLOW VELOCITY IN THE CERVICAL INTERNAL CAROTID ARTERIES
    PERTUISET, B
    ANCRI, D
    ARTHUIS, F
    BASSET, JY
    FUSCIARDI, J
    NAKANO, H
    JOURNAL OF NEURORADIOLOGY, 1985, 12 (03) : 165 - 178
  • [5] In Vitro Elastography of Porcine Carotid Arteries, a Validation Study.
    Boekhoven, R. W.
    Peters, M. F. J.
    Rutten, M. C. M.
    de Vosse, F. N. van
    Lopata, R. G. P.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1802 - 1805
  • [6] PULSED DOPPLER - A CLASSIFICATION OF RESULTS OF DIAMETER, VELOCITY AND VOLUME FLOW MEASUREMENT IN DISEASED COMMON CAROTID ARTERIES
    FITZGERALD, DE
    OSHAUGHNESSY, AM
    KEAVENY, VT
    CARDIOVASCULAR RESEARCH, 1983, 17 (02) : 122 - 126
  • [7] Pulse Wave Velocity Measurement in Healthy and Diseased Carotid Arteries In Vivo
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [8] Phase velocity cine MRI measurement of pulsatile blood flow: In vitro and in vivo validation
    Powell, AJ
    Chung, T
    Maier, SE
    Geva, T
    CIRCULATION, 1997, 96 (08) : 1047 - 1047
  • [9] Doppler flow measurement using surface integration of velocity vectors (SIVV):: In vitro validation
    Chew, MS
    Brandberg, J
    Canard, P
    Sloth, E
    Ask, P
    Hasenkam, JM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (02): : 255 - 262
  • [10] MEASUREMENT OF PHASIC CAROTID ARTERY FLOW VELOCITY IN MAN
    BENCHIMOL, A
    BARRETO, EC
    GOLDSTEIN, MR
    GARTLAN, JL
    AMERICAN JOURNAL OF MEDICINE, 1970, 49 (02): : 170 - +