Colour velocity flow measurement: In vitro validation and application to human carotid arteries

被引:39
|
作者
Deane, CR [1 ]
Markus, HS [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,DEPT NEUROL,LONDON SE5 9RS,ENGLAND
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1997年 / 23卷 / 03期
关键词
ultrasonics; carotid artery; cerebral blood flow; DOPPLER ULTRASOUND; BLOOD-FLOW;
D O I
10.1016/S0301-5629(96)00224-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound measurement of volume blood flow is potentially useful for many clinical situations, yet practical implementation and use are restricted by the many instrumentation and blood flow limitations that can arise. Colour velocity imaging offers a number of theoretical advantages over methods based on duplex imaging. We evaluated a colour velocity flow measurement system (CVI-Q, Philips) both in a flow phantom and in vivo in the extracranial carotid arteries of normal volunteers. Over a range of constant (50-1200 ml/min) and pulsatile (92-366 ml/min) flows and using both steered and unsteered beams with beam angles of 30 degrees and 40 degrees, errors usually within 5% were obtained for constant flow and within 10% for pulsatile flow. However, with a beam angle of 70 degrees, higher errors of 20% were obtained for pulsatile flow. The reproducibility of flow measurements made using both anterior and posterior-lateral scanning approaches was determined in the common (CCA), internal (ICA) and external carotid (EGA) arteries of 18 volunteers. A greater reproducibility was found using the posterior-lateral approach (CCA 6.27%; ICA 9.8%), and mean (SD) flow values were 376 ml/min in the CCA and 255 ml/min in the ICA. The ratio of (ICA + ECA)/CCA flow calculated for each subject individually was mean (SD) 0.95 (0.11). Insonation from an anterior approach resulted in lower reproducibility and lower flow values. In conclusion, colour flow velocity imaging allows repeatable reproducible measurements of CCA and ICA flow, but results are optimal if a posterior-lateral scanning approach is used. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:447 / 452
页数:6
相关论文
共 50 条
  • [31] Investigation of the effect of different flow rates on the cell viability of fresh carotid arteries in vitro
    Morticelli, L.
    Kalozoumis, P.
    Jentsch, J.
    Boeer, U.
    Wilhelmi, M.
    Haverich, A.
    Korossis, S.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S274 - S274
  • [32] DOPPLERSONOGRAPHIC MEASUREMENT OF NORMAL VALUES FOR FLOW VELOCITIES IN THE INTERNAL CAROTID ARTERIES OF HEALTHY INFANTS
    DEEG, KH
    RUPPRECHT, TH
    MONATSSCHRIFT KINDERHEILKUNDE, 1988, 136 (04) : 193 - 199
  • [33] ELECTROMAGNETIC MEASUREMENT OF BLOOD FLOW THROUGH INTACT HUMAN ARTERIES
    SPENCER, MP
    DENISON, AB
    MCGUIRE, WF
    MYERS, RT
    AMERICAN JOURNAL OF MEDICINE, 1955, 19 (01): : 153 - 153
  • [34] Evaluation of blood flow velocity waveform in common carotid artery using multi-branched arterial segment model of human arteries
    Masuda, M.
    Emoto, T.
    Suzuki, A.
    Akutagawa, M.
    Kitawaki, T.
    Kitaoka, K.
    Tanaka, H.
    Obara, S.
    Yoshizaki, K.
    Konaka, S.
    Kinouchi, Y.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) : 509 - 519
  • [35] IN VITRO VALIDATION OF MRI MEASUREMENT OF SYSTEMIC TO PULMONARY COLLATERAL FLOW
    Whitehead, Kevin K.
    Doddasomayajula, Ravi
    Dori, Yoav
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E469 - E469
  • [36] In vitro validation of volumetric blood flow measurement using Doppler flow wire
    Jenni, R
    Kaufmann, PA
    Jiang, ZH
    Attenhofer, C
    Linka, A
    Mandinov, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08): : 1301 - 1310
  • [37] Flow velocity and flow volume measurements in the extracranial carotid and vertebral arteries in healthy adults:: Reference data and the effects of age
    Scheel, P
    Ruge, C
    Schöning, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08): : 1261 - 1266
  • [38] Carotid blood flow measurement accelerated by compressed sensing: Validation in healthy volunteers
    Tao, Yuehui
    Rilling, Gabriel
    Davies, Mike
    Marshall, Ian
    MAGNETIC RESONANCE IMAGING, 2013, 31 (09) : 1485 - 1491
  • [39] Velocity measurement of in vitro blood flow in microchip cultured endothelial cells
    Segawa, Naoki
    Sugil, Yasuhiko
    PROCEEDINGS OF THE MICRO/NANOSCALE HEAT TRANSFER INTERNATIONAL CONFERENCE 2008, PTS A AND B, 2008, : 1393 - 1397
  • [40] PULSED DOPPLER - DETERMINATION OF BLOOD VELOCITY AND VOLUME FLOW IN NORMAL AND DISEASED COMMON CAROTID ARTERIES IN MAN
    FITZGERALD, DE
    OSHAUGHNESSY, AM
    KEAVENY, VT
    CARDIOVASCULAR RESEARCH, 1982, 16 (04) : 220 - 224