Colour velocity flow measurement: In vitro validation and application to human carotid arteries

被引:39
|
作者
Deane, CR [1 ]
Markus, HS [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,DEPT NEUROL,LONDON SE5 9RS,ENGLAND
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1997年 / 23卷 / 03期
关键词
ultrasonics; carotid artery; cerebral blood flow; DOPPLER ULTRASOUND; BLOOD-FLOW;
D O I
10.1016/S0301-5629(96)00224-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound measurement of volume blood flow is potentially useful for many clinical situations, yet practical implementation and use are restricted by the many instrumentation and blood flow limitations that can arise. Colour velocity imaging offers a number of theoretical advantages over methods based on duplex imaging. We evaluated a colour velocity flow measurement system (CVI-Q, Philips) both in a flow phantom and in vivo in the extracranial carotid arteries of normal volunteers. Over a range of constant (50-1200 ml/min) and pulsatile (92-366 ml/min) flows and using both steered and unsteered beams with beam angles of 30 degrees and 40 degrees, errors usually within 5% were obtained for constant flow and within 10% for pulsatile flow. However, with a beam angle of 70 degrees, higher errors of 20% were obtained for pulsatile flow. The reproducibility of flow measurements made using both anterior and posterior-lateral scanning approaches was determined in the common (CCA), internal (ICA) and external carotid (EGA) arteries of 18 volunteers. A greater reproducibility was found using the posterior-lateral approach (CCA 6.27%; ICA 9.8%), and mean (SD) flow values were 376 ml/min in the CCA and 255 ml/min in the ICA. The ratio of (ICA + ECA)/CCA flow calculated for each subject individually was mean (SD) 0.95 (0.11). Insonation from an anterior approach resulted in lower reproducibility and lower flow values. In conclusion, colour flow velocity imaging allows repeatable reproducible measurements of CCA and ICA flow, but results are optimal if a posterior-lateral scanning approach is used. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:447 / 452
页数:6
相关论文
共 50 条
  • [21] Noninvasive Measurement of Steady and Pulsating Velocity Profiles and Shear Rates in Arteries Using Echo PIV: In Vitro Validation Studies
    Hyoung-Bum Kim
    Jean Hertzberg
    Craig Lanning
    Robin Shandas
    Annals of Biomedical Engineering, 2004, 32 : 1067 - 1076
  • [22] Noninvasive measurement of steady and pulsating velocity profiles and shear rates in arteries using echo PIV:: In vitro validation studies
    Kim, HB
    Hertzberg, J
    Lanning, C
    Shandas, R
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (08) : 1067 - 1076
  • [23] BLOOD FLOW MEASUREMENT IN PTFE HEMODIALYSIS GRAFTS (HG) BY ULTRASOUND VELOCITY DILUTION (IN-VITRO VALIDATION)
    KRIVITSKI, NM
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 496 - 496
  • [24] MR flow quantification using RACE: Clinical application to the carotid arteries
    Moller, HE
    Klocke, HK
    Bongartz, GM
    Peters, PE
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03) : 503 - 512
  • [25] The blood pressure variability and blood flow velocity in the vertebral and internal carotid arteries in hypertensives
    Denisova, GA
    Balahonova, TV
    Oschepkova, EV
    Rogoza, AN
    Atkov, OY
    JOURNAL OF HYPERTENSION, 2002, 20 : S354 - S354
  • [26] Noninvasive Transthoracic and Transesophageal Doppler Echocardiographic Measurements of Human Coronary Blood Flow Velocity: In Vitro Flow Phantom Validation
    Greene, E. R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3784 - 3787
  • [27] Validation of a novel ultrasound system for integrated evaluation of blood flow velocity profile and wall displacement in human large arteries
    Vittone, F
    Morganti, T
    Kozàkovà, M
    Ricci, S
    Palombo, C
    Tortoli, P
    JOURNAL OF HYPERTENSION, 2004, 22 : S58 - S59
  • [28] PULSED DOPPLER - DETERMINATION OF BLOOD VELOCITY FLOW AND VOLUME FLOW IN NORMAL AND DISEASED COMMON CAROTID ARTERIES IN MAN
    FITZGERALD, DE
    SHAUGHNESSY, AM
    KEAVENY, VT
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (654): : 481 - 481
  • [29] Effect of Acupuncture on Blood Flow Velocity and Volume in Common Carotid and Vertebral Arteries in Migraine Patients
    Park, Kyu-Hyun
    Kim, Hak-Jin
    Baek, Sun-Yong
    Cho, Byung-Mann
    Yoo, Tae-Woo
    MEDICAL ACUPUNCTURE, 2009, 21 (01) : 47 - 54
  • [30] Investigation of the effect of different flow rates on the cell viability of fresh carotid arteries in vitro
    Morticelli, L.
    Kalozoumis, P.
    Jentsch, J.
    Boeer, U.
    Wilhelmi, M.
    Korossis, S.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2014, 8 : 390 - 390