Transcoronary pacing Reliability during myocardial ischemia and after implantation of a coronary stent

被引:0
|
作者
Heinroth, K. M. [1 ]
Unverzagt, S. [2 ]
Mahnkopf, D. [3 ]
Prondzinsky, R. [4 ]
机构
[1] Martin Luther Univ Halle Wittenberg, Dept Med 3, Ernst Grube Str 40, D-06097 Halle, Germany
[2] Martin Luther Univ Halle Wittenberg, Inst Med Epidemiol Biostat & Informat, Halle, Germany
[3] IMTR GmbH, Rottmersleben, Germany
[4] Carl von Basedow Klinikum Saalekreis gGmbH, Dept Med 1, Merseburg, Germany
关键词
Bradycardia; Temporary pacing; Coronary artery disease; Guidewire; Myocardial infarction; COMPLICATIONS; BRADYCARDIA; INFARCTION; MODEL;
D O I
10.1007/s00063-018-0492-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcoronary pacing is a useful therapeutic option for the treatment of unheralded bradycardias in the setting of percutaneous coronary interventions (PCI). Objectives In the present study, we investigated the influence of stent implantation and transient myocardial ischemia on the feasibility of transcoronary pacing in a porcine model. Methods. 7 adult pigs underwent a percutaneous coronary intervention with implantation of a coronary stent under general anaesthesia in an animal catheterization laboratory. Transcoronary pacing was established by using a standard guidewire isolated with an angioplasty balloon positioned in the periphery of the right coronary artery serving as the cathode. As the indifferent anode, a skin patch electrode at the back of the animal was used. The reliability of transcoronary pacing was assessed by measurement of threshold and impedance data and the magnitude of the epicardial electrogram at baseline, after implantation of a coronary stent and finally during myocardial ischemia. Results. Effective transcoronary pacing could be demonstrated in all cases with the standard unipolar transcoronary pacing setup yielding a low pacing threshold at baseline of 1.3 +/- 0.8 V with an impedance of 283 +/- 67 Omega. Implantation of a coronary stent did not influence the pacing threshold (1.0 +/- 0.4 V) and impedance (262 +/- 63 Omega). Acute myocardial ischemia lead to a significant but clinically nonrelevant increase of the pacing threshold to 2.0 +/- 0.6 V and a drop in pacing impedance (137 +/- 39 Omega). Conclusions. Transcoronary pacing in the animal model is not affected by implantation of a coronary stent in the same vessel used for pacing. Despite a significant increase in pacing threshold, the transcoronary pacing approach is reliable in acute myocardial ischemia during a percutaneous coronary intervention.
引用
收藏
页码:120 / 124
页数:5
相关论文
共 50 条
  • [41] Circulating monocytes and in-stent neointima after coronary stent implantation
    Fukuda, D
    Shimada, K
    Tanaka, A
    Kawarabayashi, T
    Yoshiyama, M
    Yoshikawa, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (01) : 18 - 23
  • [42] Incidence and predictors of definite stent thrombosis after coronary stent implantation
    ZHANG Quan-yu
    LI Yi
    GUAN Shao-yi
    WANG Xiao-zeng
    JING Quan-min
    MA Ying-yan
    WANG Geng
    WANG Bin
    DENG Jie
    HAN Ya-ling
    中华医学杂志(英文版), 2012, (09) : 1547 - 1551
  • [43] Incidence and predictors of definite stent thrombosis after coronary stent implantation
    Zhang Quan-yu
    Li Yi
    Guan Shao-yi
    Wang Xiao-zeng
    Jing Quan-min
    Ma Ying-Yan
    Wang Geng
    Wang Bin
    Deng Jie
    Han Ya-ling
    CHINESE MEDICAL JOURNAL, 2012, 125 (09) : 1547 - 1551
  • [44] Impact of stent design on clinical outcome after coronary stent implantation
    Poerner, TC
    Haase, KK
    Duda, S
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2002, 11 (04) : 203 - 209
  • [45] Incomplete Stent Apposition after Coronary Stent Implantation: Myth or Reality?
    Rathore, Sudhir
    Terashima, Mitsuyasu
    Habara, M.
    Kinoshita, Yoshihisa
    Nasu, Kenya
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (04) : 341 - 349
  • [46] THE EFFECTS OF GLOBAL MYOCARDIAL ISCHEMIA FOLLOWED BY REPERFUSION ON TRANSCORONARY EXCHANGE DURING CARDIOPULMONARY BYPASS
    MCDONAGH, PF
    GOLDMAN, N
    LAKS, H
    MICROCIRCULATION, 1982, 2 (03): : 243 - 270
  • [47] EFFECT OF HIGH-DOSE ASPIRIN ON CORONARY HEMODYNAMICS DURING PACING-INDUCED MYOCARDIAL ISCHEMIA
    MARTIN, JL
    FISHER, CA
    UNTEREKER, WJ
    LASKEY, WK
    HIRSHFELD, JW
    HARKEN, AH
    ADDONIZIO, VP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 210 - 215
  • [48] EFFECT OF INTRACORONARY NIFEDIPINE ON CORONARY BLOODFLOW AND MYOCARDIAL-METABOLISM DURING PACING-INDUCED ISCHEMIA
    KIMBALL, BP
    MILDENBERGER, RR
    LEFKOWITZ, CA
    ROSS, BL
    HOULE, S
    MCLAUGHLIN, PR
    CANADIAN JOURNAL OF CARDIOLOGY, 1990, 6 (08) : 333 - 339
  • [49] Microcirculatory vasoconstriction during myocardial ischemia induced by atrial pacing tachycardia in patients with coronary artery disease
    Sambuceti, G
    Marzilli, M
    Fedele, S
    Marraccini, P
    L'Abbate, A
    CIRCULATION, 1998, 98 (17) : 487 - 487
  • [50] MYOCARDIAL POTASSIUM-LOSS DURING TACHYCARDIA, PACING INDUCED ISCHEMIA, AND CORONARY-OCCLUSION IN MAN
    WEBB, SC
    CANEPAANSON, R
    POOLEWILSON, PA
    BRITISH HEART JOURNAL, 1984, 51 (01): : 118 - 118