Transcoronary pacing Reliability during myocardial ischemia and after implantation of a coronary stent

被引:0
|
作者
Heinroth, K. M. [1 ]
Unverzagt, S. [2 ]
Mahnkopf, D. [3 ]
Prondzinsky, R. [4 ]
机构
[1] Martin Luther Univ Halle Wittenberg, Dept Med 3, Ernst Grube Str 40, D-06097 Halle, Germany
[2] Martin Luther Univ Halle Wittenberg, Inst Med Epidemiol Biostat & Informat, Halle, Germany
[3] IMTR GmbH, Rottmersleben, Germany
[4] Carl von Basedow Klinikum Saalekreis gGmbH, Dept Med 1, Merseburg, Germany
关键词
Bradycardia; Temporary pacing; Coronary artery disease; Guidewire; Myocardial infarction; COMPLICATIONS; BRADYCARDIA; INFARCTION; MODEL;
D O I
10.1007/s00063-018-0492-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcoronary pacing is a useful therapeutic option for the treatment of unheralded bradycardias in the setting of percutaneous coronary interventions (PCI). Objectives In the present study, we investigated the influence of stent implantation and transient myocardial ischemia on the feasibility of transcoronary pacing in a porcine model. Methods. 7 adult pigs underwent a percutaneous coronary intervention with implantation of a coronary stent under general anaesthesia in an animal catheterization laboratory. Transcoronary pacing was established by using a standard guidewire isolated with an angioplasty balloon positioned in the periphery of the right coronary artery serving as the cathode. As the indifferent anode, a skin patch electrode at the back of the animal was used. The reliability of transcoronary pacing was assessed by measurement of threshold and impedance data and the magnitude of the epicardial electrogram at baseline, after implantation of a coronary stent and finally during myocardial ischemia. Results. Effective transcoronary pacing could be demonstrated in all cases with the standard unipolar transcoronary pacing setup yielding a low pacing threshold at baseline of 1.3 +/- 0.8 V with an impedance of 283 +/- 67 Omega. Implantation of a coronary stent did not influence the pacing threshold (1.0 +/- 0.4 V) and impedance (262 +/- 63 Omega). Acute myocardial ischemia lead to a significant but clinically nonrelevant increase of the pacing threshold to 2.0 +/- 0.6 V and a drop in pacing impedance (137 +/- 39 Omega). Conclusions. Transcoronary pacing in the animal model is not affected by implantation of a coronary stent in the same vessel used for pacing. Despite a significant increase in pacing threshold, the transcoronary pacing approach is reliable in acute myocardial ischemia during a percutaneous coronary intervention.
引用
收藏
页码:120 / 124
页数:5
相关论文
共 50 条
  • [31] Temporary transcoronary pacing by coated guidewiresA safe and reliable method during percutaneous coronary intervention
    Konstantin M. Heinroth
    Ina Stabenow
    Ines Moldenhauer
    Susanne Unverzagt
    Michael Buerke
    Karl Werdan
    Roland Prondzinsky
    Clinical Research in Cardiology, 2006, 95 : 206 - 211
  • [32] Temporary transcoronary pacing by coated guidewires - A safe and reliable method during percutaneous coronary intervention
    Heinroth, KM
    Stabenow, I
    Moldenhauer, I
    Unverzagt, S
    Buerke, M
    Werdan, K
    Prondzinsky, R
    CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (04) : 206 - 211
  • [33] PLATELET DEPOSITION IN CORONARY VASCULATURE DURING AND AFTER GLOBAL MYOCARDIAL ISCHEMIA
    ROSENBAUM, DS
    FEINBERG, H
    LEVITSKY, S
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 436 - 436
  • [34] ST MONITORING FOR MYOCARDIAL-ISCHEMIA DURING AND AFTER CORONARY ANGIOPLASTY
    MIZUTANI, M
    FREEDMAN, SB
    BARNS, E
    OGASAWARA, S
    BAILEY, BP
    BERNSTEIN, L
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (04): : 389 - 393
  • [35] Usefulness of stress myocardial perfusion imaging for evaluating asymptomatic patients after coronary stent implantation
    Sugi, T
    Satoh, H
    Uehara, A
    Katoh, H
    Terada, H
    Matsunaga, M
    Yamazaki, K
    Matoh, F
    Nakano, T
    Yoshihara, S
    Kurata, C
    Miyata, H
    Ukigai, H
    Tawarahara, K
    Kimura, M
    Suzuki, S
    Hayashi, H
    CIRCULATION JOURNAL, 2004, 68 (05) : 462 - 466
  • [36] Angiographic Iongterm follow-up after coronary stent implantation in acute myocardial infarction
    Ailaiti Maimaitiming
    Hans-Jrgen Rupprecht
    Flex Post
    Bernd Nowak
    Jrgen Meyer
    中国介入心脏病学杂志, 1998, (04) : 156 - 156
  • [37] Usefulness of exercise tomographic myocardial perfusion imaging for detection of restenosis after coronary stent implantation
    Galassi, AR
    Foti, R
    Azzarelli, S
    Coco, G
    Condorelli, G
    Russo, G
    Musumeci, S
    Tamburino, C
    Giuffrida, G
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (11): : 1362 - +
  • [38] Coronary angioplasty with or without stent implantation for acute myocardial infarction
    Grines, CL
    Cox, DA
    Stone, GW
    Garcia, E
    Mattos, LA
    Giambartolomei, A
    Brodie, BR
    Madonna, O
    Eijgelshoven, M
    Lansky, AJ
    O'Neill, WW
    Morice, MC
    NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (26): : 1949 - 1956
  • [39] Flow variation during direct acute myocardial infarction angioplasty with coronary stent implantation.
    Chevalier, B
    Glatt, B
    Guyon, P
    Royer, T
    Stratiev, V
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 2S - 2S
  • [40] Percutaneous Left Main Coronary Artery Stent for Acute Myocardial Ischemia after Repaired ALCAPA
    Hallbergson, Anna
    Rome, Jonathan J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (06) : 1017 - 1020