Transcoronary pacing Reliability during myocardial ischemia and after implantation of a coronary stent

被引:0
|
作者
Heinroth, K. M. [1 ]
Unverzagt, S. [2 ]
Mahnkopf, D. [3 ]
Prondzinsky, R. [4 ]
机构
[1] Martin Luther Univ Halle Wittenberg, Dept Med 3, Ernst Grube Str 40, D-06097 Halle, Germany
[2] Martin Luther Univ Halle Wittenberg, Inst Med Epidemiol Biostat & Informat, Halle, Germany
[3] IMTR GmbH, Rottmersleben, Germany
[4] Carl von Basedow Klinikum Saalekreis gGmbH, Dept Med 1, Merseburg, Germany
关键词
Bradycardia; Temporary pacing; Coronary artery disease; Guidewire; Myocardial infarction; COMPLICATIONS; BRADYCARDIA; INFARCTION; MODEL;
D O I
10.1007/s00063-018-0492-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcoronary pacing is a useful therapeutic option for the treatment of unheralded bradycardias in the setting of percutaneous coronary interventions (PCI). Objectives In the present study, we investigated the influence of stent implantation and transient myocardial ischemia on the feasibility of transcoronary pacing in a porcine model. Methods. 7 adult pigs underwent a percutaneous coronary intervention with implantation of a coronary stent under general anaesthesia in an animal catheterization laboratory. Transcoronary pacing was established by using a standard guidewire isolated with an angioplasty balloon positioned in the periphery of the right coronary artery serving as the cathode. As the indifferent anode, a skin patch electrode at the back of the animal was used. The reliability of transcoronary pacing was assessed by measurement of threshold and impedance data and the magnitude of the epicardial electrogram at baseline, after implantation of a coronary stent and finally during myocardial ischemia. Results. Effective transcoronary pacing could be demonstrated in all cases with the standard unipolar transcoronary pacing setup yielding a low pacing threshold at baseline of 1.3 +/- 0.8 V with an impedance of 283 +/- 67 Omega. Implantation of a coronary stent did not influence the pacing threshold (1.0 +/- 0.4 V) and impedance (262 +/- 63 Omega). Acute myocardial ischemia lead to a significant but clinically nonrelevant increase of the pacing threshold to 2.0 +/- 0.6 V and a drop in pacing impedance (137 +/- 39 Omega). Conclusions. Transcoronary pacing in the animal model is not affected by implantation of a coronary stent in the same vessel used for pacing. Despite a significant increase in pacing threshold, the transcoronary pacing approach is reliable in acute myocardial ischemia during a percutaneous coronary intervention.
引用
收藏
页码:120 / 124
页数:5
相关论文
共 50 条
  • [1] Transcoronary pacing: Reliability during myocardial ischemia and after implantation of a coronary stent; [Transkoronare Stimulation: Zuverlässigkeit unter Myokardischämie und nach Implantation eines Koronarstents]
    Heinroth K.M.
    Unverzagt S.
    Mahnkopf D.
    Prondzinsky R.
    Medizinische Klinik - Intensivmedizin und Notfallmedizin, 2020, 115 (2) : 120 - 124
  • [2] TRANSCORONARY CARDIAC PACING DURING MYOCARDIAL-ISCHEMIA
    LAIRD, JR
    HULL, R
    STAJDUHAR, KC
    WESTON, LT
    KUFS, W
    WORTHAM, DC
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (02): : 162 - 165
  • [3] Coronary Stent Immobilization During Angioplasty by Transcoronary Ventricular Pacing Via a Guidewire
    Lasa, Garikoitz
    Larman, Mariano
    Gaviria, Koldo
    Carlos Sanmartin, Juan
    Sadaba, Mario
    Ramon Rumoroso, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (03): : 288 - 292
  • [4] TRANSCORONARY PACING DURING PERCUTANEOUS CORONARY INTERVENTION
    Carter, J. M.
    Heinroth, K.
    Buerke, M.
    Mahnkopf, D.
    Werdan, K.
    Prondzinsky, R.
    HEART, 2009, 95 : A26 - A26
  • [5] Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation
    Rodés-Cabau, J
    Candell-Riera, J
    Domingo, E
    Castell-Conesa, J
    Anívarro, I
    Angel, J
    Aguadé-Bruix, S
    Padilla, F
    Soto, A
    Soler-Soler, J
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (12) : 1768 - 1772
  • [6] Left Main Coronary Stent Positioning Using Rapid Transcoronary Pacing
    O'Sullivan, Crochan J.
    Meier, Bernhard
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (01): : E4 - E7
  • [7] Scintigraphic changes in myocardial perfusion after coronary stent implantation
    Zalc, S
    Martinez, EE
    Soares, J
    Giorgi, MCP
    Ribeiro, E
    Esteves, A
    Horta, PE
    Ramires, JAF
    EUROPEAN HEART JOURNAL, 2002, 23 : 26 - 26
  • [8] Myocardial perfusion scintigraphy to evaluate patients after coronary stent implantation
    Kósa, I
    Blasini, R
    Schneider-Eicke, J
    Neumann, FJ
    Matsunari, C
    Neverve, J
    Schömig, A
    Schwaiger, M
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1307 - 1311
  • [9] Prognostic value of myocardial ischemia detected by Technetium-99m Myoview SPECT after coronary stent implantation
    Bokeria, L
    Aslanidis, I
    Alekiyn, B
    Mukhortova, O
    Vachromeeva, M
    Shurupova, I
    Klueva, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S307 - S307
  • [10] Ischemia detection by intracoronary ECG after stent implantation in coronary bifurcation lesions
    Vassilev, Dobrin
    Pehlivanova, Milena
    Alexandrov, Alexander
    Hazan, Maxim
    Kostova, Elena
    Pavlov, Pavlin
    Golebiewski, Slawomir
    Gil, Robert
    Simova, Iana
    Christov, Ivaylo
    Bortolan, Giovanni Giovanni
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B81 - B81